A CFD based thermo-hydraulic performance analysis of an artificially roughened solar air heater having equilateral triangular sectioned rib roughness on the absorber plate

Abstract In this article, a numerical investigation is conducted to analyze the two-dimensional incompressible Navier–Stokes flows through the artificially roughened solar air heater for relevant Reynolds number ranges from 3800 to 18,000. Twelve different configurations of equilateral triangular sectioned rib ( P/e  = 7.14–35.71 and e/d  = 0.021–0.042) have been used as roughness element. The governing equations are solved with a finite-volume-based numerical method. The commercial finite-volume based CFD code ANSYS FLUENT is used to simulate turbulent airflow through artificially roughened solar air heater. The RNG k–e turbulence model is used to solve the transport equations for turbulent flow energy and dissipation rate. A total numbers of 432,187 quad grid intervals with a near wall elements spacing of y +  ≈ 2 are used. Detailed results about average heat transfer and fluid friction in an artificially roughened solar air heater are presented and discussed. The effects of grid distributions on the numerical predictions are also discussed. It has been observed that for a given constant value of heat flux (1000 W/m 2 ), the performance of the artificially roughened solar air heater is strong function of the Reynolds number, relative roughness pitch and relative roughness height. Optimum configuration of the roughness element for artificially roughened solar air heater is evaluated.

[1]  J. L. Bhagoria,et al.  A Numerical Investigation of Turbulent Flows through an Artificially Roughened Solar Air Heater , 2014 .

[2]  B. N. Prasad,et al.  Investigation for the optimal thermohydraulic performance of artificially roughened solar air heaters , 2000 .

[3]  J. Saini,et al.  Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater , 2008 .

[4]  A. R. Jaurker,et al.  Heat transfer and friction characteristics of rectangular solar air heater duct using rib-grooved artificial roughness , 2006 .

[5]  J. L. Bhagoria,et al.  Heat transfer and friction in solar air heater duct with W-shaped rib roughness on absorber plate , 2011 .

[6]  B. Launder,et al.  Lectures in mathematical models of turbulence , 1972 .

[7]  B. N. Prasad Thermal performance of artificially roughened solar air heaters , 2013 .

[8]  R. Saini,et al.  Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having arc-shaped wire as artificial roughness , 2008 .

[9]  J. L. Bhagoria,et al.  Modeling and Simulation of Turbulent Flows through a Solar Air Heater Having Square-Sectioned Transverse Rib Roughness on the Absorber Plate , 2013, TheScientificWorldJournal.

[10]  V. S. Hans,et al.  Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs , 2010 .

[11]  E. Eckert,et al.  Application of rough surfaces to heat exchanger design , 1972 .

[12]  A. N. Tikekar,et al.  Analysis of fluid flow and heat transfer in a rib grit roughened surface solar air heater using CFD , 2010 .

[13]  S. Bopche,et al.  Experimental investigations on heat transfer and frictional characteristics of a turbulator roughened solar air heater duct , 2009 .

[14]  S. Chander,et al.  Heat transfer and friction factor correlations of solar air heater ducts artificially roughened with discrete V-down ribs , 2011 .

[15]  R. Saini,et al.  Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having multi v-shaped with gap rib as artificial roughness , 2013 .

[16]  P. Promvonge,et al.  Thermal performance assessment of turbulent channel flows over different shaped ribs , 2008 .

[17]  B. N. Prasad,et al.  Effect of artificial roughness on heat transfer and friction factor in a solar air heater , 1988 .

[18]  S. Mullick,et al.  Heat transfer characteristics of a solar air heater used for drying purposes , 1983 .

[19]  J. L. Bhagoria,et al.  A CFD (computational fluid dynamics) based heat transfer and fluid flow analysis of a solar air heater provided with circular transverse wire rib roughness on the absorber plate , 2013 .

[20]  R. Saini,et al.  Experimental investigation on heat transfer and fluid flow characteristics of air flow in a rectangular duct with Multi v-shaped rib with gap roughness on the heated plate , 2012 .

[21]  J. L. Bhagoria,et al.  Heat transfer and fluid flow analysis of solar air heater: A review of CFD approach , 2013 .

[22]  Pongjet Promvonge,et al.  Numerical study on heat transfer of turbulent channel flow over periodic grooves , 2008 .

[23]  R. Saini,et al.  Heat transfer and friction factor correlations for a duct having dimple-shape artificial roughness for solar air heaters , 2008 .

[24]  J. Nikuradse Laws of Flow in Rough Pipes , 1950 .

[25]  Rajendra Karwa,et al.  Performance study of solar air heater having v-down discrete ribs on absorber plate , 2013 .

[26]  A. D. Young,et al.  An Introduction to Fluid Mechanics , 1968 .

[27]  S. C. Solanki,et al.  Thermo-hydraulic performance of solar air heaters having integral chamfered rib roughness on absorber plates , 2001 .

[28]  J. L. Bhagoria,et al.  Heat transfer and fluid flow analysis of an artificially roughened solar air heater: a CFD based investigation , 2014 .

[29]  Lei Wang,et al.  Experimental investigation of local heat transfer in a square duct with various-shaped ribs , 2007 .

[30]  Varun,et al.  Correlations for solar air heater duct with dimpled shape roughness elements on absorber plate , 2012 .

[31]  S. C. Solanki,et al.  Heat transfer and friction in solar air heater duct with V-shaped rib roughness on absorber plate , 2002 .

[32]  J. L. Bhagoria,et al.  Numerical investigation of flow through an artificially roughened solar air heater , 2015 .

[33]  R. Karwa EXPERIMENTAL STUDIES OF AUGMENTED HEAT TRANSFER AND FRICTION IN ASYMMETRICALLY HEATED RECTANGULAR DUCTS WITH RIBS ON THE HEATED WALL IN TRANSVERSE, INCLINED, V-CONTINUOUS AND V-DISCRETE PATTERN , 2003 .

[34]  R. Saini,et al.  CFD based performance analysis of a solar air heater duct provided with artificial roughness , 2009 .

[35]  S. C. Solanki,et al.  Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate , 2002 .

[36]  Giovanni Tanda,et al.  Performance of solar air heater ducts with different types of ribs on the absorber plate , 2011 .

[37]  J. L. Bhagoria,et al.  Heat transfer and friction correlations for artificially roughened solar air heater duct with discrete W-shaped ribs , 2009 .

[38]  S. C. Solanki,et al.  Thermohydraulic performance of solar air heaters with roughened absorber plates , 1997 .

[39]  S. C. Solanki,et al.  Heat transfer and friction characteristics for artificially roughened ducts with compound turbulators , 2007 .

[40]  S. Patankar Numerical Heat Transfer and Fluid Flow , 2018, Lecture Notes in Mechanical Engineering.

[41]  S. C. Solanki,et al.  Heat transfer coefficient and friction factor correlations for the transitional flow regime in rib-roughened rectangular ducts , 1999 .

[42]  Varun,et al.  Investigation of thermal performance of solar air heater having roughness elements as a combination of inclined and transverse ribs on the absorber plate , 2008 .

[43]  S. C. Solanki,et al.  Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heater , 2006 .

[44]  R. P. Saini,et al.  Heat transfer and friction factor correlations for artificially roughened ducts with expanded metal mesh as roughness element , 1997 .

[45]  A. N. Tikekar,et al.  Heat transfer and friction factor correlation for artificially roughened duct with metal grit ribs , 2007 .

[46]  J. L. Bhagoria,et al.  Augmentation of heat transfer coefficient by using 90° broken transverse ribs on absorber plate of solar air heater , 2005 .