Abstract Spatial distributions in surface flux and concentrations complicate the assessment of indoor mass-transfer coefficients and can bias the resulting estimates of indoor exposure. To better understand these phenomena, we quantify the spatial distribution of ozone flux and mass-transfer coefficients for indoor surfaces in several field locations using NaNO2 coated filters. The 12-h average transport-limited deposition velocity for ozone, v ¯ t , ozone , corrected for the diameter of the filters, ranged from 1.2 m h−1 on a wall to 18.7 m h−1 near an operating recirculation supply vent in an apartment. For 10 filters distributed evenly around walls of a laboratory, large multi-person office, apartment with recirculation on (excluding a near-supply vent sample) and apartment with recirculation off, the average v ¯ t , ozone were respectively, 3.3±1.1, 3.5±1.3, 2.8±0.8 and 2.3±0.8 m h−1. We observed (1) a tighter distribution of flux for filters placed near one-another than for filters separated by greater than one meter, (2) higher fluxes near sources of air movement such as supply vents and computers, and (3) consistent results in a single location over 5 days. Measurements obtained with devices such as coated filters can be corrected for size by using a range of device sizes during an experiment. We find the mass-transfer coefficient in a room-sized laboratory chamber to be proportional to the device diameter raised to the power of −0.45.
[1]
Glenn Morrison,et al.
Temporal considerations in the measurement of indoor mass transfer coefficients
,
2006
.
[2]
G. Cass,et al.
Nitric acid concentrations in southern California museums
,
1990
.
[3]
William W. Nazaroff,et al.
Novel approach for tomographic reconstruction of gas concentration distributions in air: Use of smooth basis functions and simulated annealing
,
1996
.
[4]
G. Cass,et al.
Particle deposition from a natural convection flow onto a vertical isothermal flat plate
,
1987
.
[5]
R. Shah,et al.
Handbook of single-phase convective heat transfer
,
1987
.
[6]
Glenn Morrison,et al.
Rapid measurement of indoor mass-transfer coefficients
,
2003
.
[7]
C J Weschler,et al.
Indoor ozone exposures.
,
1989,
JAPCA.
[8]
William W. Nazaroff,et al.
Critique of the Use of Deposition Velocity in Modeling Indoor Air Quality
,
1993
.
[9]
Tracy L. Thatcher,et al.
Effects of room furnishings and air speed on particle deposition rates indoors
,
2002
.
[10]
Leslie E. Sparks,et al.
Gas-Phase Mass Transfer Model for Predicting Volatile Organic Compound (VOC) Emission Rates from Indoor Pollutant Sources
,
1996
.