K‐space description for MR imaging of dynamic objects

The spatial frequency (k) space concept is extended to describe the imaging of time‐dependent objects. This work builds on the existing k‐space description of MRI and is useful for simplifying the analysis of explanations of motion artifacts, algorithms for the correction of motion, and efficient imaging schemes for dynamic objects. Specific examples of the use of this concept for different imaging techniques are presented.

[1]  Albert Macovski,et al.  A linear class of large-tip-angle selective excitation pulses , 1989 .

[2]  C. Ahn,et al.  High-Speed Spiral-Scan Echo Planar NMR Imaging-I , 1986, IEEE Transactions on Medical Imaging.

[3]  R C Grimm,et al.  Recursive RF excitation , 1992, Magnetic resonance in medicine.

[4]  E. Haacke,et al.  Pseudo‐gating: Elimination of periodic motion artifacts in magnetic resonance imaging without gating , 1987, Magnetic resonance in medicine.

[5]  H. Barrett,et al.  Computerized tomography: taking sectional x rays , 1977 .

[6]  S Dunne,et al.  Fast Fourier projection for MR angiography , 1991, Magnetic resonance in medicine.

[7]  Kim Butts,et al.  Analysis of flow effects in echo‐planar imaging , 1992, Journal of magnetic resonance imaging : JMRI.

[8]  P. Lauterbur,et al.  Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance , 1973, Nature.

[9]  G. Glover Multipoint dixon technique for water and fat proton and susceptibility imaging , 1991, Journal of magnetic resonance imaging : JMRI.

[10]  V M Runge,et al.  Respiratory gating in magnetic resonance imaging at 0.5 Tesla. , 1984, Radiology.

[11]  R M Henkelman,et al.  Suppression of respiratory motion artifacts in magnetic resonance imaging. , 1986, Medical physics.

[12]  S. Riederer,et al.  Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imaging , 1990, Magnetic resonance in medicine.

[13]  R R Edelman,et al.  Detection of hepatic metastases: analysis of pulse sequence performance in MR imaging. , 1986, Radiology.

[14]  R M Henkelman,et al.  Dynamic image reconstruction: MR movies from motion ghosts , 1992, Journal of magnetic resonance imaging : JMRI.

[15]  D. Twieg,et al.  A general treatment of NMR imaging with chemical shifts and motion , 1987, Magnetic resonance in medicine.

[16]  M E Brummer,et al.  Acquisition order and motional artifact reduction in spin warp images , 1988, Magnetic resonance in medicine.

[17]  W. T. Dixon Simple proton spectroscopic imaging. , 1984, Radiology.

[18]  O. Simonetti,et al.  Theoretical aspects of motion sensitivity and compensation in echo‐planar imaging , 1991, Journal of magnetic resonance imaging : JMRI.

[19]  R M Henkelman,et al.  Motion artifact reduction with three‐point ghost phase cancellation , 1991, Journal of magnetic resonance imaging : JMRI.

[20]  P. Mansfield Multi-planar image formation using NMR spin echoes , 1977 .

[21]  T A Spraggins,et al.  Wireless retrospective gating: application to cine cardiac imaging. , 1990, Magnetic resonance imaging.

[22]  R. Bracewell Strip Integration in Radio Astronomy , 1956 .

[23]  P. R. Moran,et al.  A unified description of NMR imaging, data-collection strategies, and reconstruction. , 1984, Medical physics.

[24]  A. G. Collins,et al.  Respiratory ordered phase encoding (ROPE): a method for reducing respiratory motion artefacts in MR imaging. , 1985, Journal of computer assisted tomography.

[25]  W. Edelstein,et al.  Spin warp NMR imaging and applications to human whole-body imaging. , 1980, Physics in medicine and biology.

[26]  S. Ljunggren A simple graphical representation of fourier-based imaging methods , 1983 .

[27]  E M Haacke,et al.  Reducing motion artifacts in two-dimensional Fourier transform imaging. , 1986, Magnetic resonance imaging.

[28]  D. Twieg The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods. , 1983, Medical physics.

[29]  L Kaufman,et al.  Magnetic resonance imaging strategies for heart studies. , 1984, Radiology.

[30]  R E Wendt,et al.  Motional phase artifacts in fourier transform MRI , 1989, Magnetic resonance in medicine.