Robotic system for MRI-guided shoulder arthrography: Accuracy evaluation

This paper introduces a body mounted robotic system for MRI-guided shoulder arthrography in pediatric patients. This robotic manipulator is optimized for being accurate yet light enough to perform the contrast agent injection and joint examination imaging inside the MRI bore. The robotic manipulator has 4 degrees of freedom (DOF) providing accurate insertion trajectory of the injection needle. In shoulder arthrography procedures, contrast agent is injected under fluoroscope guidance resulting in radiation exposure which should be avoided for pediatric patients. Also after contrast agent injection typically MRI images are acquired for examination resulting in two stage procedure. The presented system allows clinicians to perform both contrast agent injection and joint examination under MRI guidance, hence completely eliminating radiation exposure from fluoroscope guidance and patient movement from X-Ray/CT room to MRI suite. The presented system contains no ferrous components and is considered MR-Conditional. The bench-top accuracy evaluation of the robotic manipulator shows average pose error of 1.22 mm in position and 1 degree in orientation at the needle tip.

[1]  Kevin Cleary,et al.  A prototype body-mounted MRI-compatible robot for needle guidance in shoulder arthrography , 2014, 5th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics.

[2]  Kemal Tuncali,et al.  Design evaluation of a double ring RCM mechanism for robotic needle guidance in MRI-guided liver interventions , 2013, 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[3]  Conor J. Walsh,et al.  A Patient-Mounted, Telerobotic Tool for CT-Guided Percutaneous , 2008 .

[4]  Nobuhiko Hata,et al.  Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy , 2015, IEEE/ASME Transactions on Mechatronics.

[5]  Berk Gonenc,et al.  MRI-guided needle steering for targets in motion based on Fiber Bragg Grating sensors , 2016, 2016 IEEE SENSORS.

[6]  Nikolai Hungr,et al.  Design and Validation of a CT- and MRI-Guided Robot for Percutaneous Needle Procedures , 2016, IEEE Transactions on Robotics.

[7]  P. Cinquin,et al.  Light Puncture Robot for CT and MRI Interventions , 2008, IEEE Engineering in Medicine and Biology Magazine.

[8]  Milan Sonka,et al.  3D Slicer as an image computing platform for the Quantitative Imaging Network. , 2012, Magnetic resonance imaging.

[9]  G. Fichtinger,et al.  Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention , 2013, IEEE/ASME Transactions on Mechatronics.

[10]  Jacques Gangloff,et al.  A Patient-Mounted Robotic Platform for CT-Scan Guided Procedures , 2008, IEEE Transactions on Biomedical Engineering.

[11]  Dan Stoianovici,et al.  MR Safe Robot, FDA Clearance, Safety and Feasibility of Prostate Biopsy Clinical Trial , 2017, IEEE/ASME Transactions on Mechatronics.

[12]  C. Corot,et al.  Allergy-like reactions to iodinated contrast agents. A critical analysis. , 2005, Fundamental & clinical pharmacology.

[13]  Gang Li,et al.  In‐bore prostate transperineal interventions with an MRI‐guided parallel manipulator: system development and preliminary evaluation , 2016, The international journal of medical robotics + computer assisted surgery : MRCAS.

[14]  Pedro Moreira,et al.  The MIRIAM Robot: A Novel Robotic System for MR-Guided Needle Insertion in the Prostate , 2017, J. Medical Robotics Res..

[15]  Gang Li,et al.  Closed-loop asymmetric-tip needle steering under continuous intraoperative MRI guidance , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[16]  Hao Su,et al.  Robotic System for MRI-Guided Stereotactic Neurosurgery , 2015, IEEE Transactions on Biomedical Engineering.

[17]  Faye Y. Wu,et al.  An MRI Coil-Mounted Multi-Probe Robotic Positioner for Cryoablation , 2013 .

[18]  Jaydev P. Desai,et al.  Toward the Development of a Flexible Mesoscale MRI-Compatible Neurosurgical Continuum Robot , 2017, IEEE Transactions on Robotics.