Energy and CO2 emissions performance assessment of residential micro-cogeneration systems with dynamic whole-building simulation programs

Abstract Micro-cogeneration, also termed micro combined heat and power (MCHP) or residential cogeneration, is an emerging technology with the potential to provide energy efficiency and environmental benefits by reducing primary energy consumption and associated greenhouse gas emissions. The distributed generation nature of the technology also has the potential to reduce losses due to electrical transmission and distribution inefficiencies and to alleviate utility peak demand problems. Detailed MCHP models for whole-building simulation tools, developed in Annex 42 of the International Energy Agency (IEA) Energy Conservation in Buildings and Community Systems Programme, have been used to conduct a performance assessment study for a number of micro-cogeneration systems and residential buildings. Annual non-renewable primary energy (NRPE) demand and CO 2 -equivalent (CO 2 -eq) emissions were determined by simulation for different cogeneration technologies, namely natural gas-fuelled solid oxide (SOFC) and polymer electrolyte membrane fuel cells, Stirling and internal combustion engines. These were compared to the reference system with a gas boiler and electricity supply from the grid. A ground-coupled heat pump system was also analysed for comparison. The cogeneration units were integrated in single and multi-family houses of different energy standard levels. Two different electricity generation mixes were considered: European mix and combined cycle power plant (CCPP). For the MCHP devices, detailed dynamic component models as well as simplified performance map models were used, developed and calibrated with either results from laboratory experiments or with manufacturer data. The simulations were performed using the whole-building simulation programme TRNSYS, using domestic hot water and electric demand profiles specified in IEA Annex 42. Combinations of three demand levels were analyzed. In NRPE demand, for the European electricity mix, most MCHP systems offered reductions (up to 34%) in comparison with the gas boiler reference system and crediting the electricity exported to the grid. For the CCPP electricity generation mix, the largest NRPE reductions resulted for the ground-coupled heat pump systems (up to 29%). The maximum reduction with a cogeneration system was 14%. In terms of CO 2 -eq emissions, most cogeneration systems offered reductions for the European electricity mix (up to 22%). However, maximum reductions resulted for the heat pump system (23%). For the CCPP mix, maximum reductions by far again resulted for the heat pump systems (up to 29%). The maximum reduction for a cogeneration system was achieved with the ICE system in the single-family house (14%).

[1]  V. Ismet Ugursal,et al.  Modeling of internal combustion engine based cogeneration systems for residential applications , 2007 .

[2]  Martin Pehnt,et al.  Assessing future energy and transport systems: the case of fuel cells , 2003 .

[3]  M. Newborough,et al.  Effect of heat-saving measures on the CO2 savings attributable to micro-combined heat and power (μCHP) systems in UK dwellings , 2008 .

[4]  Martin Pehnt,et al.  Environmental impacts of distributed energy systems—The case of micro cogeneration , 2008 .

[5]  Cecilia Wallmark,et al.  Design of stationary PEFC system configurations to meet heat and power demands , 2002 .

[6]  V. Ismet Ugursal,et al.  The financial viability of an SOFC cogeneration system in single-family dwellings , 2006 .

[7]  Viktor Dorer,et al.  Performance assessment of fuel cell micro-cogeneration systems for residential buildings , 2005 .

[8]  Adam Hawkes,et al.  Solid oxide fuel cell systems for residential micro-combined heat and power in the UK: Key economic drivers , 2005 .

[9]  Adam Hawkes,et al.  Impacts of temporal precision in optimisation modelling of micro-combined heat and power , 2005 .

[10]  François Maréchal,et al.  Thermo‐Economic Modelling and Optimisation of Fuel Cell Systems , 2005 .

[11]  Laura Vanoli,et al.  Micro-combined heat and power in residential and light commercial applications , 2003 .

[12]  Adam Hawkes,et al.  Techno-economic modelling of a solid oxide fuel cell stack for micro combined heat and power , 2006 .

[13]  Evgueniy Entchev,et al.  Residential fuel cell energy systems performance optimization using “soft computing” techniques , 2003 .

[14]  William D'haeseleer,et al.  The evaluation of small cogeneration for residential heating , 2002 .

[15]  Zong-ci Zhao,et al.  Climate change 2001, the scientific basis, chap. 8: model evaluation. Contribution of Working Group I to the Third Assessment Report of the Intergovernmental Panel on Climate Change IPCC , 2001 .

[16]  Adam Hawkes,et al.  Cost-effective operating strategy for residential micro-combined heat and power , 2007 .

[17]  Carlo Roselli,et al.  Assessment of micro-cogeneration potential for domestic trigeneration , 2007 .

[18]  H.-M. Groscurth,et al.  Optimization of solar district heating systems: seasonal storage, heat pumps, and cogeneration , 2000 .

[19]  H.-M. Groscurth,et al.  Competition and synergy between energy technologies in municipal energy systems , 1997 .

[20]  Nick Kelly,et al.  A comparative assessment of future heat and power sources for the UK domestic sector , 2006 .

[21]  Martin Pehnt Assessing future energy and transport systems: the case of fuel cells , 2003 .

[22]  Adam Hawkes,et al.  Solid oxide fuel cell micro combined heat and power system operating strategy: Options for provision of residential space and water heating , 2007 .

[23]  Adam Hawkes,et al.  The capacity credit of micro-combined heat and power , 2008 .

[24]  François Maréchal,et al.  A methodology for thermo-economic modeling and optimization of solid oxide fuel cell systems , 2007 .

[25]  William D'haeseleer,et al.  Reinventing hot water?: Towards optimal sizing and management of cogeneration: A case study for Belgium , 2006 .

[26]  D Mertens,et al.  Micro-CHP systems for residential applications , 2006 .

[27]  M. Newborough,et al.  Impact of micro-CHP systems on domestic sector CO2 emissions , 2005 .

[28]  Lieve Helsen,et al.  The impact of thermal storage on the operational behaviour of residential CHP facilities and the overall CO2 emissions , 2007 .

[29]  Carlo Roselli,et al.  Experimental analysis of micro-cogeneration units based on reciprocating internal combustion engine , 2006 .

[30]  M. Newborough,et al.  Impact of micro-combined heat-and-power systems on energy flows in the UK electricity supply industry , 2006 .