Improvements in the control of a flexible endoscopic system

The use of flexible cable-driven systems is common in medicine (endoscope, catheter...). Their flexiblity allows surgeons to reach internal organs through sinuous and constrained ways. Unfortunately these systems are subject to backlash due to their internal mechanism. These non linearities raise many difficulties when robotizing and controlling such systems. In this article we propose an approach to improve the cartesian control of a four ways flexible endoscopic system with strong and unknown backlash-like non linearities. The method is based on an automatic off-line hystereses learning. We show that, despite coupling between degrees of freedom, it is possible to extract information from the hystereses which allow to improve cartesian control. Experiments on a real endoscopic system show the validity and the interest of the approach.

[1]  John Kenneth Salisbury,et al.  Configuration Tracking for Continuum Manipulators With Coupled Tendon Drive , 2009, IEEE Transactions on Robotics.

[2]  Mattias Nordin,et al.  Controlling mechanical systems with backlash - a survey , 2002, Autom..

[3]  B. Bardou,et al.  Design of a telemanipulated system for transluminal surgery ‡ , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  Philippe Zanne,et al.  Control of a multiple sections flexible endoscopic system , 2010, 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[5]  L. Phee,et al.  Ergonomic master controller for flexible endoscopic gastrointestinal robot manipulator , 2006, 2006 International Conference on Biomedical and Pharmaceutical Engineering.

[6]  Farrokh Janabi-Sharifi,et al.  Catheter Kinematics for Intracardiac Navigation , 2009, IEEE Transactions on Biomedical Engineering.

[7]  Frank L. Lewis,et al.  A fuzzy system compensator for backlash , 1998, Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146).

[8]  Gang Tao,et al.  Adaptive Control of Systems with Backlash , 1992 .

[9]  William J. Peine,et al.  Design of an endoluminal NOTES robotic system , 2007, 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[10]  Ian D. Walker,et al.  A New Approach to Jacobian Formulation for a Class of Multi-Section Continuum Robots , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[11]  C. C. Davis,et al.  Control strategies for tendon-driven manipulators , 1990, IEEE Control Systems Magazine.

[12]  J.A. De Abreu-Garcia,et al.  Tracking control of a piezoceramic actuator with hysteresis compensation using inverse Preisach model , 2005, IEEE/ASME Transactions on Mechatronics.

[13]  B. Yao,et al.  Modeling of a closed loop cable-conduit transmission system , 2008, 2008 IEEE International Conference on Robotics and Automation.

[14]  Farshad Khorrami,et al.  Adaptive control of systems with backlash hysteresis at the input , 1999, Proceedings of the 1999 American Control Conference (Cat. No. 99CH36251).

[15]  Bin Yao,et al.  Control of cable actuated devices using smooth backlash inverse , 2010, 2010 IEEE International Conference on Robotics and Automation.

[16]  Jinwoo Jung,et al.  Towards closed loop control of a continuum robotic manipulator for medical applications , 2011, 2011 IEEE International Conference on Robotics and Automation.

[17]  Qingwei Chen,et al.  Adaptive robust control for nonlinear system with input backlash or backlash-like hysteresis , 2009, 2009 IEEE International Conference on Control and Automation.

[18]  M. Kaneko,et al.  Basic considerations on transmission characteristics for tendon drive robots , 1991, Fifth International Conference on Advanced Robotics 'Robots in Unstructured Environments.

[19]  Philippe Zanne,et al.  Robotic Assistance to Flexible Endoscopy by Physiological-Motion Tracking , 2011, IEEE Transactions on Robotics.