Analytical application of poly{methyl[3-(2-hydroxy-3,4-difluoro)phenyl]propyl siloxane} as a QCM coating for DMMP detection.

A new material-poly{methyl[3-(2-hydroxy-3,4-difluoro)phenyl]propyl siloxane}(PMDFPS) sensitive to toxic organophosphate vapor was synthesized with 2,3-difluorophenol, allyl bromide and poly (methyl hydrosiloxane) as raw materials, via O-alkylation, Claisen rearrange reaction and hydrosilylation reaction. This novel material was then coated on a quartz crystal microbalance (QCM) to investigate its gas sensitive properties to the nerve agent simulant dimethyl methylphosphonate (DMMP) vapor, as well as known interfering vapors. When tested with competing vapors, the sensor was more than 10 times sensitive to DMMP than to other interfering vapors. Thus, high selectivity of poly{methyl[3-(2-hydroxy-3,4-difluoro)phenyl]propyl siloxane} to DMMP was demonstrated. The poly{methyl[3-(2-hydroxy-3,4-difluoro)phenyl]propyl siloxane}-QCM sensor responded linearly to DMMP vapor with a slope of 14 Hz/ppm in the 1-50 ppm range with a detection limit of 0.21 ppm (S/N=3).

[1]  R Chung,et al.  Rational materials design of sorbent coatings for explosives: applications with chemical sensors. , 2001, Talanta.

[2]  J. Grate,et al.  Hydrogen bond acidic polymers for surface acoustic wave vapor sensors and arrays. , 1999, Analytical chemistry.

[3]  F. Worek,et al.  Diagnostic aspects of organophosphate poisoning. , 2005, Toxicology.

[4]  R. A. McGill,et al.  Performance optimization of surface acoustic wave chemical sensors , 1998 .

[5]  Bin Hu,et al.  Optimization of a single-drop microextraction procedure for the determination of organophosphorus pesticides in water and fruit juice with gas chromatography-flame photometric detection. , 2006, Talanta.

[6]  Todd E. Mlsna,et al.  Chemicapacitive Microsensors for Chemical Warfare Agent and Toxic Industrial Chemical Detection , 2006 .

[7]  U. Brinkman,et al.  Application of microcolumn liquid chromatography and capillary electrophoresis with flame photometric detection for the screening of degradation products of chemical warfare agents in water and soil. , 2001, Journal of chromatography. A.

[8]  Dominique Rebière,et al.  A love-wave gas sensor coated with functionalized polysiloxane for sensing organophosphorus compounds , 2001 .

[9]  Junsheng Yu,et al.  PVDF coated quartz crystal microbalance sensor for DMMP vapor detection , 2007 .

[10]  C. Kientz,et al.  Capillary gas chromatographic analysis of nerve agents using large volume injections. , 1996, Journal of chromatography. A.

[11]  E. Menzel,et al.  Rapid fluorophosphate nerve agent detection with lanthanides. , 2005, Talanta.

[12]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[13]  Dominique Rebière,et al.  Synthesis and evaluation of fluoropolyol isomers as saw microsensor coatings: role of humidity and temperature , 1998 .

[14]  M. D. Crenshaw,et al.  In-line respeciation: an ion-exchange ion chromatographic method applied to the separation of degradation products of chemical warfare nerve agents in soil. , 1997, Journal of chromatography. A.

[15]  R. W. Warren,et al.  Atomic emission detection for the quantitation of trimethylsilyl derivatives of chemical-warfare-agent related compounds in environmental samples , 1995 .

[16]  D. H. Moore Long term health effects of low dose exposure to nerve agent , 1998, Journal of Physiology-Paris.

[17]  B A Eckenrode,et al.  Environmental and Forensic applications of field-portable GC-MS: An overview , 2001, Journal of the American Society for Mass Spectrometry.

[18]  Ada Fort,et al.  A measurement system for odor classification based on the dynamic response of QCM sensors , 2003, IEEE Trans. Instrum. Meas..