Comparative Studies on the Impedance Models of VSC-Based Renewable Generators for SSI Stability Analysis

Recently, emerging oscillation issues have been caused by subsynchronous interaction (SSI) between voltage source converters (VSCs) based renewable generators and ac/dc grids. To investigate the dynamics of SSI, several impedance models (IMs) of VSC have been developed in previous studies. They are established in different reference frames and consider the entire or just parts of the control systems. However, it is still an unanswered question whether or not the existing IMs are suitable for SSI analysis and to what extent the IMs with different modeling details affect subsynchronous dynamics. To fill in this gap, this paper, first, reviews the existing IMs of VSC and clarifies their relationship. Then, their frequency characteristics are examined so as to select the proper models for the studies of sub-/supersynchronous and high-frequency dynamics. Next, both zero-pole and IM-based SSI analyses are carried out on a simplified system and a real-world wind-farm system that suffered actual SSI incidents. The results indicate that the outer-loop control has a significant impact on the subsynchronous dynamics, and only those IMs taking full-scale controls and frequency-coupling effects into account can reflect SSI accurately. Finally, both modal analysis and electromagnetic transient simulations have been conducted to verify the theoretical results.

[1]  B. Pal,et al.  Stability Analysis of a PMSG-Based Large Offshore Wind Farm Connected to a VSC-HVDC , 2018, IEEE Transactions on Energy Conversion.

[2]  Jiabing Hu,et al.  Analysis of Low-Frequency Stability in Grid-Tied DFIGs by Nonminimum Phase Zero Identification , 2018, IEEE Transactions on Energy Conversion.

[3]  Leila Parsa,et al.  Impedance Modeling of Three-Phase Voltage Source Converters in DQ, Sequence, and Phasor Domains , 2017, IEEE Transactions on Energy Conversion.

[4]  Wei Liu,et al.  An Oscillatory Stability Criterion Based on the Unified $dq$ -Frame Impedance Network Model for Power Systems With High-Penetration Renewables , 2018, IEEE Transactions on Power Systems.

[5]  Xu Cai,et al.  A Modified Sequence-Domain Impedance Definition and Its Equivalence to the dq-Domain Impedance Definition for the Stability Analysis of AC Power Electronic Systems , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[6]  Kit Po Wong,et al.  Cooperation-Driven Distributed Control Scheme for Large-Scale Wind Farm Active Power Regulation , 2017, IEEE Transactions on Energy Conversion.

[7]  Jian Sun,et al.  Small-Signal Methods for AC Distributed Power Systems–A Review , 2009, IEEE Transactions on Power Electronics.

[8]  Lingling Fan,et al.  Nyquist-Stability-Criterion-Based SSR Explanation for Type-3 Wind Generators , 2012, IEEE Transactions on Energy Conversion.

[9]  Zhixin Miao,et al.  Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network , 2012, IEEE Transactions on Energy Conversion.

[10]  Marta Molinas,et al.  Small-Signal Stability Assessment of Power Electronics Based Power Systems: A Discussion of Impedance- and Eigenvalue-Based Methods , 2017, IEEE Transactions on Industry Applications.

[11]  Jinjun Liu,et al.  Infinity-Norm of Impedance-Based Stability Criterion for Three-Phase AC Distributed Power Systems With Constant Power Loads , 2015, IEEE Transactions on Power Electronics.

[12]  Hui Liu,et al.  Quantitative SSR Analysis of Series-Compensated DFIG-Based Wind Farms Using Aggregated RLC Circuit Model , 2017, IEEE Transactions on Power Systems.

[13]  Xiuchen Jiang,et al.  Protected Control Method for Power Conversion Interface Under Unbalanced Operating Conditions in AC/DC Hybrid Distributed Grid , 2016, IEEE Transactions on Energy Conversion.

[14]  A. Platzker,et al.  Rigorous determination of the stability of linear n-node circuits from network determinants and the appropriate role of the stability factor K of their reduced two-ports , 1994, Third International Workshop on Integrated Nonlinear Microwave and Millimeterwave Circuits.

[15]  Jiabing Hu,et al.  Small Signal Instability of PLL-Synchronized Type-4 Wind Turbines Connected to High-Impedance AC Grid During LVRT , 2016, IEEE Transactions on Energy Conversion.

[16]  Xu Cai,et al.  On the Impedance Modeling and Equivalence of AC/DC-Side Stability Analysis of a Grid-Tied Type-IV Wind Turbine System , 2019, IEEE Transactions on Energy Conversion.

[17]  Wei Ren,et al.  A Refined Frequency Scan Approach to Sub-Synchronous Control Interaction (SSCI) Study of Wind Farms , 2016, IEEE Transactions on Power Systems.

[18]  Mohsen Hamzeh,et al.  High-Frequency Oscillations and Their Leading Causes in DC Microgrids , 2017, IEEE Transactions on Energy Conversion.

[19]  Zhao Yu,et al.  Subsynchronous Interaction Between Direct-Drive PMSG Based Wind Farms and Weak AC Networks , 2017, IEEE Transactions on Power Systems.

[20]  Frede Blaabjerg,et al.  Unified Impedance Model of Grid-Connected Voltage-Source Converters , 2018, IEEE Transactions on Power Electronics.

[21]  Amirnaser Yazdani,et al.  A Power Mismatch Elimination Strategy for an MMC-Based Photovoltaic System , 2018, IEEE Transactions on Energy Conversion.

[22]  Bo Wen,et al.  Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters , 2016, IEEE Transactions on Power Electronics.

[23]  Jian Sun,et al.  Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters , 2014, IEEE Transactions on Power Electronics.

[24]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[25]  Weiwei Li,et al.  Analysis of Resonance Between a VSC-HVDC Converter and the AC Grid , 2018, IEEE Transactions on Power Electronics.

[26]  Frede Blaabjerg,et al.  Couplings in Phase Domain Impedance Modeling of Grid-Connected Converters , 2016, IEEE Transactions on Power Electronics.

[27]  Hui Liu,et al.  Stability Analysis of SSR in Multiple Wind Farms Connected to Series-Compensated Systems Using Impedance Network Model , 2018, IEEE Transactions on Power Systems.

[28]  Jian Sun,et al.  Sequence Impedance Modeling and Analysis of Type-III Wind Turbines , 2018, IEEE Transactions on Energy Conversion.

[29]  R. Midence,et al.  New microprocessor based relay to monitor and protect power systems against sub-harmonics , 2011, 2011 IEEE Electrical Power and Energy Conference.

[30]  Heng Nian,et al.  Frequency Coupling Characteristic Modeling and Stability Analysis of Doubly Fed Induction Generator , 2018, IEEE Transactions on Energy Conversion.

[31]  Hui Liu,et al.  Characteristic Analysis of Subsynchronous Resonance in Practical Wind Farms Connected to Series-Compensated Transmissions , 2017, IEEE Transactions on Energy Conversion.

[32]  A. Dixit,et al.  Ercot experience screening for Sub-Synchronous Control Interaction in the vicinity of series capacitor banks , 2012, 2012 IEEE Power and Energy Society General Meeting.

[33]  Xu Cai,et al.  Sequence Domain SISO Equivalent Models of a Grid-Tied Voltage Source Converter System for Small-Signal Stability Analysis , 2018, IEEE Transactions on Energy Conversion.