Real part of refractive index measurement approach for absorbing liquid.

An algorithm based on use of a reflected refractometer to measure the real part of the refractive index (RI) for an absorbing liquid is presented. The absorption of liquid will blur the division between bright and dark regions on a Fresnel reflective curve. However, the reflective ratio at some incident angles that are less than the critical angle have little sensitivity to absorbability. Unlike common methods that extract RI from reflectivity in critical angle vicinity, the presented method acquires the real RI from reflective ratio at a subcritical angle. Supported by the theoretical analysis and experimental results on a reflected refractometer, we have achieved accuracy better than 3×10(-4) RIU on ink samples with absorption coefficient around 300  cm(-1). Additional tests on Alizarin yellow GG solutions prove that the subcritical algorithm is feasible and of high accuracy.

[1]  J. P. Woerdman,et al.  Observing angular deviations in the specular reflection of a light beam , 2009 .

[2]  Augusto García-Valenzuela,et al.  Optical model enabling the use of Abbe-type refractometers on turbid suspensions. , 2013, Optics letters.

[3]  A García-Valenzuela,et al.  Reflectivity of a gaussian beam near the critical angle with external optically absorbing media. , 2000, Applied optics.

[4]  A. García-Valenzuela,et al.  Understanding the performance of Abbe-type refractometers with optically absorbing fluids , 2014 .

[5]  S. Bali,et al.  Real-time differential refractometry without interferometry at a sensitivity level of 10(-6). , 2006, Applied optics.

[6]  R. Barrera,et al.  Extension of Fresnel's formulas for turbid colloidal suspensions: a rigorous treatment. , 2014, The journal of physical chemistry. B.

[7]  G. Meeten,et al.  Refractive index measurement of turbid colloidal fluids by transmission near the critical angle , 1991 .

[8]  R. Barrera,et al.  Nonlocal nature of the electrodynamic response of colloidal systems , 2007 .

[9]  G. Meeten,et al.  Errors in critical-angle measurement of refractive index of optically absorbing materials , 1984 .

[10]  L. M. Bali,et al.  Empirical model of total internal reflection from highly turbid media. , 2013, Optics letters.

[11]  M. Born Principles of Optics : Electromagnetic theory of propagation , 1970 .

[12]  Kecheng Yang,et al.  A two-reflection divergent differentiating critical angle refractometer. , 2011, The Review of scientific instruments.

[13]  Kecheng Yang,et al.  A local curve-fitting method for the complex refractive index measurement of turbid media , 2012 .

[14]  A. Penzkofer,et al.  Refractive-index measurement of absorbing condensed media. , 1984, Applied optics.

[15]  Jukka Räty,et al.  Assessment of wavelength dependent complex refractive index of strongly light absorbing liquids. , 2012, Optics express.

[16]  R. Finsy,et al.  Laser light refractometer. , 1984, Applied optics.

[17]  A. García-Valenzuela,et al.  Refractive index measurement of turbid media by transmission of backscattered light near the critical angle. , 2014, Applied optics.

[18]  I. Šimon Spectroscopy in Infrared by Reflection and Its Use for Highly Absorbing Substances , 1951 .

[19]  L. M. Bali,et al.  New approach to the measurement of refractive index , 2005 .

[20]  R. Tousey On Calculating the Optical Constants from Reflection Coefficients , 1939 .

[21]  Jukka Räty,et al.  Reflectance Study of Milk in the UV-Visible Range , 1999 .

[22]  L. M. Bali,et al.  Measurement of the refractive index of highly turbid media. , 2010, Optics letters.

[23]  L. M. Bali,et al.  Sensitive real-time measurement of the refractive index and attenuation coefficient of milk and milk-cream mixtures. , 2010, Journal of dairy science.

[24]  G. Meeten,et al.  Refractive index measurement of absorbing and turbid fluids by reflection near the critical angle , 1995 .

[25]  M. Mohammadi Colloidal refractometry : meaning and measurement of refractive index for dispersions ; the science that time forgot , 1995 .

[26]  K. Peiponen,et al.  Complex refractive index of turbid liquids. , 2007, Optics letters.

[27]  Comparison of Reflection Methods for Measuring Optical Constants without Polarimetric Analysis, and Proposal for New Methods based on the Brewster Angle , 2016 .