Out-of-field photon and neutron dose equivalents from step-and-shoot intensity-modulated radiation therapy.

PURPOSE To measure the photon and neutron out-of-treatment-field dose equivalents to various organs from different treatment strategies (conventional vs. intensity-modulated radiation therapy [IMRT]) at different treatment energies and delivered by different accelerators. METHODS AND MATERIALS Independent measurements were made of the photon and neutron out-of-field dose equivalents resulting from one conventional and six IMRT treatments for prostate cancer. The conventional treatment used an 18-MV beam from a Clinac 2100; the IMRT treatments used 6-MV, 10-MV, 15-MV, and 18-MV beams from a Varian Clinac 2100 accelerator and 6-MV and 15-MV beams from a Siemens Primus accelerator. Photon doses were measured with thermoluminescent dosimeters in a Rando phantom, and neutron fluence was measured with gold foils. Dose equivalents to the colon, liver, stomach, lung, esophagus, thyroid, and active bone marrow were determined for each treatment approach. RESULTS For each treatment approach, the relationship between dose equivalent per MU, distance from the treatment field, and depth in the patient was examined. Photon dose equivalents decreased approximately exponentially with distance from the treatment field. Neutron dose equivalents were independent of distance from the treatment field and decreased with increasing tissue depth. Neutrons were a significant contributor to the out-of field dose equivalent for beam energies > or =15 MV. CONCLUSIONS Out-of-field photon and neutron dose equivalents can be estimated to any point in a patient undergoing a similar treatment approach from the distance of that point to the central axis and from the tissue depth. This information is useful in determining the dose to critical structures and in evaluating the risk of associated carcinogenesis.

[1]  M. Cristy,et al.  Active bone marrow distribution as a function of age in humans. , 1981, Physics in medicine and biology.

[2]  J. Cameron The Relative Biological Effectiveness of Radiations of Different Quality, NCRP Report 104 , 1992 .

[3]  Omar Chibani,et al.  Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs. , 2003, Medical physics.

[4]  D Verellen,et al.  Risk assessment of radiation-induced malignancies based on whole-body equivalent dose estimates for IMRT treatment in the head and neck region. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  A. B. Brill,et al.  NCRP Report No. 116, Limitation of Exposure to Ionizing Radiation National Council on Radiation Protection, Bethesda, MD, 88 pages, $22.50 , 1994 .

[6]  K. W. Price,et al.  Neutron Measurements Around High Energy X-Ray Radiotherapy Machines , 1986 .

[7]  D W O Rogers,et al.  Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code. , 2002, Medical physics.

[8]  S. Mutic,et al.  A reduction in the AAPM TG-36 reported peripheral dose distributions with tertiary multileaf collimation. American Association of Physicists in Medicine Task Group 36. , 1999, International journal of radiation oncology, biology, physics.

[9]  K. Kase,et al.  Measurements of dose from secondary radiation outside a treatment field. , 1983, International journal of radiation oncology, biology, physics.

[10]  R. Nath,et al.  Depth dose-equivalent and effective energies of photoneutrons generated by 6-18 MV X-ray beams for radiotherapy. , 2001, Health physics.

[11]  R. Shore,et al.  Unwanted radiation produced by leakage neutrons from medical electron accelerators. , 1982, Medical physics.

[12]  E. Gallego,et al.  Response components of LiF:Mg,Ti around a moderated Am-Be neutron source. , 2002, Radiation protection dosimetry.

[13]  Robert J. Shalek,et al.  Fetal Dose from Radiotherapy with Photon Beams , 1995 .

[14]  R. Stern Peripheral dose from a linear accelerator equipped with multileaf collimation. , 1999, Medical physics.

[15]  K. Kase,et al.  Neutron fluence and energy spectra around the Varian Clinac 2100C/2300C medical accelerator. , 1998, Health physics.

[16]  A. Torresin,et al.  Neutron measurements around medical electron accelerators by active and passive detection techniques. , 1991, Medical physics.

[17]  H. M. Liu,et al.  Gamma dose measurement in a water phantom irradiated with the BNCT facility at THOR. , 2001, Radiation protection dosimetry.

[18]  J. S. Laughlin,et al.  Phosphorus activation neutron dosimetry and its application to an 18-MV radiotherapy accelerator. , 1982, Medical physics.

[19]  J. Landry,et al.  TECHNICAL NOTE: Neutron contamination of X-ray beams produced by the Varian Clinac 1800 , 1989 .

[20]  M. Griem Neutron Contamination From Medical Electron Accelerators , 1985 .

[21]  W F Hanson,et al.  Uncertainty analysis of absorbed dose calculations from thermoluminescence dosimeters. , 1992, Medical physics.

[22]  J. Palta,et al.  Neutron leakage measurements from a medical linear accelerator. , 1984, Medical physics.

[23]  R. C. McCall,et al.  Transport of Accelerator Produced Neutrons in a Concrete Room , 1978, IEEE Transactions on Nuclear Science.

[24]  R. C. McCall Neutron yield of medical electron accelerators , 1987 .

[25]  C R Blackwell,et al.  Fetal dose from radiotherapy with photon beams: report of AAPM Radiation Therapy Committee Task Group No. 36. , 1995, Medical physics.

[26]  B. Mijnheer,et al.  Determination of dose components in phantoms irradiated with an epithermal neutron beam for boron neutron capture therapy. , 1995, Medical physics.

[27]  K. Kase,et al.  Neutron sources in the Varian Clinac 2100C/2300C medical accelerator calculated by the EGS4 code. , 1997, Health physics.

[28]  P. V. D. Giessen A simple and generally applicable method to estimate the peripheral dose in radiation teletherapy with high energy x-rays or gamma radiation. , 1996 .

[29]  Whole-body dose from Peacock-based IMRT treatment , 2000 .