Electromagnetic characterization of grouting materials of bridge post tensioned ducts for NDT using capacitive probe
暂无分享,去创建一个
Frédéric Taillade | D. Placko | Thierry Bore | P. Sabouroux | T. Bore | F. Taillade | P. Sabouroux | D. Placko
[1] P. Sabouroux,et al. EpsiMu, A toolkit for permittivity and permeability measurement in microwave domain at real time of all materials: Applications to solid and semisolid materials , 2010 .
[2] S. O. Nelson,et al. Measurement and applications of dielectric properties of agricultural products , 1992 .
[3] G. Klysz,et al. Use of capacitive and GPR techniques for the non-destructive evaluation of cover concrete , 2008 .
[4] Doudou Seydi Ba,et al. Optimisation d'une procédure de caractérisation électromagnétique de matériaux dans le domaine des micro-ondes : application aux milieux granulaires secs et humides , 2010 .
[5] Dominique Placko,et al. DPSM for modeling engineering problems , 2007 .
[6] Pierre Sabouroux. EpsiMu: un nouvel outil pour determiner les caracteristiques electromagnetiques de materiaux dans le domaine des hyperfrequences , 2005 .
[7] Evert C. Slob,et al. A new tool for accurate S-parameters measurements and permittivity reconstruction , 2005, IEEE Transactions on Geoscience and Remote Sensing.
[8] A. Robert. Dielectric permittivity of concrete between 50 Mhz and 1 Ghz and GPR measurements for building materials evaluation , 1998 .
[9] I. Al-Qadi,et al. Characterization of Portland cement concrete using electromagnetic waves over the microwave frequencies , 1998 .
[10] E. J. Vanzura,et al. Improved technique for determining complex permittivity with the transmission/reflection method , 1990 .
[11] Evert C. Slob,et al. Synthesis of all known analytical permittivity reconstruction techniques of nonmagnetic materials from reflection and transmission measurements , 2005, IEEE Geoscience and Remote Sensing Letters.
[12] Steve Millard,et al. Dielectric properties of concrete and their influence on radar testing , 2000 .
[13] Christophe Aubagnac,et al. Comparison of NDT techniques on a post-tensioned beam before its autopsy , 2002 .
[14] A. Robert. Recherche de méthodes d'interprétation des mesures géoradar et de thermographie infrarouge appliquées au contrôle non destructif et à l'auscultation in situ des matériaux de construction , 1997 .
[15] D. Pozar. Microwave Engineering , 1990 .
[16] Laurent Gaillet,et al. Electrochemical Behaviour And CorrosionSensitivity Of Prestressed Steel In Cement Grout , 2007 .
[17] Patrick Queffelec,et al. Coaxial/cylindrical transition line for broadband permittivity measurement of civil engineering materials , 2006 .
[18] Koji Asami,et al. Characterization of heterogeneous systems by dielectric spectroscopy , 2002 .
[19] Stefan Hurlebaus,et al. Determination of the repair grout volume to fill voids inexternal post-tensioned tendons , 2012 .
[20] Chong Kim Ong,et al. A resonant cavity for high-accuracy measurement of microwave dielectric properties , 1996 .
[21] Michael Golosovsky,et al. Near-field scanning microwave probe based on a dielectric resonator , 2001 .
[22] Wael W. El-Dakhakhni,et al. Coplanar capacitance sensors for detecting water intrusion in composite structures , 2008 .
[23] A. M. Nicolson,et al. Measurement of the Intrinsic Properties of Materials by Time-Domain Techniques , 1970 .
[24] Ugur Cem Hasar,et al. Non-destructive testing of hardened cement specimens at microwave frequencies using a simple free-space method , 2009 .
[25] D. Chung,et al. Effect of admixtures on the dielectric constant of cement paste , 2001 .
[26] Frédéric Taillade,et al. Dielectric relaxation behavior of Callovo‐Oxfordian clay rock: A hydraulic‐mechanical‐electromagnetic coupling approach , 2013 .
[27] Imad L. Al-Qadi,et al. Design and evaluation of a coaxial transmission line fixture to characterize portland cement concrete , 1997 .
[28] Weng Cho Chew,et al. Design and calibration of a large broadband dielectric measurement cell , 1991, IEEE Trans. Geosci. Remote. Sens..
[29] Isidro Sánchez,et al. Impedance spectroscopy study of hardened Portland cement paste , 2002 .
[30] Stefan Hurlebaus,et al. Non-destructive testing methods to identify voids in external post-tensioned tendons , 2012 .
[31] Elise Duroudier-Blactot. Etude des paramètres de durabilité des aciers de précontrainte dans les coulis de ciment ségrégés , 2008 .
[32] Pierre Sabouroux,et al. Simplification de la procedure de mesure de caracteristiques electromagnetiques de materiaux en temps reel , 2005 .
[33] P Chaigne,et al. MESURE DE LA TENEUR EN EAU DES SOLS ET DES MATERIAUX PAR UNE METHODE CAPACITIVE. , 1972 .
[34] Steve Millard,et al. Coaxial transmission lines: development test of procedures for concrete , 2001 .
[35] W. Weir. Automatic measurement of complex dielectric constant and permeability at microwave frequencies , 1974 .
[36] T. Bore,et al. Capacitive Sensor for Measuring the Filled of Post-Tensioned Ducts. Experimental Setup, Modeling and Signal Processing , 2013, IEEE Sensors Journal.
[37] Steve Millard,et al. The Influence Of Concrete Composition Upon Radar Test Results , 1997 .