A simple combined sample–standard bracketing and inter-element correction procedure for accurate mass bias correction and precise Zn and Cu isotope ratio measurements
暂无分享,去创建一个
Kate Peel | D. Weiss | B. Coles | T. Arnold | J. Chapman
[1] I. Rodushkin,et al. Revised exponential model for mass bias correction using an internal standard for isotope abundance ratio measurements by multi-collector inductively coupled plasma mass spectrometry , 2006 .
[2] Barry J. Coles,et al. Chemical Separation and Isotopic Variations of Cu and Zn From Five Geological Reference Materials , 2006 .
[3] Peter J. Statham,et al. The determination of the isotopic composition of Cu and Zn in seawater , 2006 .
[4] M. Chiba,et al. Precise Zn Isotopic Ratio Measurements of Human Red Blood Cell and Hair Samples by Multiple Collector-ICP-Mass Spectrometry , 2005, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[5] F. Blanckenburg,et al. An assessment of the accuracy of stable Fe isotope ratio measurements on samples with organic and inorganic matrices by high-resolution multicollector ICP-MS , 2005 .
[6] I. Butler,et al. Experimental study of the copper isotope fractionation between aqueous Cu(II) and covellite, CuS , 2004 .
[7] I. Rodushkin,et al. Sources of mass bias and isotope ratio variation in multi-collector ICP-MS: optimization of instrumental parameters based on experimental observations , 2004 .
[8] I. Rodushkin,et al. Isotopic variations of Zn in biological materials. , 2004, Analytical chemistry.
[9] D. Vance,et al. Mass discrimination correction in multiple-collector plasma source mass spectrometry: an example using Cu and Zn isotopes , 2004 .
[10] S. Russell,et al. High-precision Cu and Zn isotope analysis by plasma source mass spectrometry part 1. Spectral interferences and their correction , 2004 .
[11] B. Sharp,et al. Instrument response functions, mass bias and matrix effects in isotope ratio measurements and semi-quantitative analysis by single and multi-collector ICP-MS , 2003 .
[12] T. Hirata,et al. Absolute isotopic composition and atomic weight of commercial zinc using inductively coupled plasma mass spectrometry. , 2002, Analytical chemistry.
[13] J. Woodhead. A simple method for obtaining highly accurate Pb isotope data by MC-ICP-MS , 2002 .
[14] D. Rickard,et al. Determination of natural Cu-isotope variation by plasma-source mass spectrometry: implications for use as geochemical tracers , 2000 .
[15] Francis Albarède,et al. Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry , 1999 .
[16] D. J. Douglas,et al. Nonspectroscopic interelement interferences in inductively coupled plasma mass spectrometry , 1988 .
[17] S. S. Goldich. Natural Variations in the Abundance Ratio and the , 1965 .
[18] S. Russell,et al. High-precision Cu and Zn isotope analysis by plasma source mass spectrometry: Part 2. Correcting for mass discrimination effects , 2004 .
[19] R. Barnes,et al. Improving isotope ratio precision in inductivelycoupled plasma quadrupole mass spectrometry by common analyte internal standardization , 2001 .
[20] M. Rehkämper,et al. Investigation of matrix effects for Pb isotope ratio measurements by multiple collector ICP-MS: verification and application of optimized analytical protocols , 2000 .
[21] K. Heumann,et al. Precision and accuracy in isotope ratio measurements by plasma source mass spectrometry , 1998 .