A simple combined sample–standard bracketing and inter-element correction procedure for accurate mass bias correction and precise Zn and Cu isotope ratio measurements

The modified sample–standard bracketing method (m-SSB) combines a sample–standard bracketing and an inter-element correction procedure to account for instrumental mass fractionation during multi-collector ICP-MS measurements. Precisions for Cu and Zn isotopes in plant and experimental granite leachate samples are in line with those obtained using other mass bias correction techniques. In addition, the inherent temporal drift of mass bias during the analytical session and the empirical linear relationship between dopant and analyte are used to apply independent correction schemes that rigorously check the accuracy of mass bias correction using m-SSB. Consequently, a very robust isotope data set is obtained. We further suggest the use of a matrix-element spike in inter-element doped standards to increase the mass bias variability. This improves the quality of the empirical relationship between dopant and analyte and enables cross-checking of the m-SSB method when instrumental mass bias is stable.

[1]  I. Rodushkin,et al.  Revised exponential model for mass bias correction using an internal standard for isotope abundance ratio measurements by multi-collector inductively coupled plasma mass spectrometry , 2006 .

[2]  Barry J. Coles,et al.  Chemical Separation and Isotopic Variations of Cu and Zn From Five Geological Reference Materials , 2006 .

[3]  Peter J. Statham,et al.  The determination of the isotopic composition of Cu and Zn in seawater , 2006 .

[4]  M. Chiba,et al.  Precise Zn Isotopic Ratio Measurements of Human Red Blood Cell and Hair Samples by Multiple Collector-ICP-Mass Spectrometry , 2005, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[5]  F. Blanckenburg,et al.  An assessment of the accuracy of stable Fe isotope ratio measurements on samples with organic and inorganic matrices by high-resolution multicollector ICP-MS , 2005 .

[6]  I. Butler,et al.  Experimental study of the copper isotope fractionation between aqueous Cu(II) and covellite, CuS , 2004 .

[7]  I. Rodushkin,et al.  Sources of mass bias and isotope ratio variation in multi-collector ICP-MS: optimization of instrumental parameters based on experimental observations , 2004 .

[8]  I. Rodushkin,et al.  Isotopic variations of Zn in biological materials. , 2004, Analytical chemistry.

[9]  D. Vance,et al.  Mass discrimination correction in multiple-collector plasma source mass spectrometry: an example using Cu and Zn isotopes , 2004 .

[10]  S. Russell,et al.  High-precision Cu and Zn isotope analysis by plasma source mass spectrometry part 1. Spectral interferences and their correction , 2004 .

[11]  B. Sharp,et al.  Instrument response functions, mass bias and matrix effects in isotope ratio measurements and semi-quantitative analysis by single and multi-collector ICP-MS , 2003 .

[12]  T. Hirata,et al.  Absolute isotopic composition and atomic weight of commercial zinc using inductively coupled plasma mass spectrometry. , 2002, Analytical chemistry.

[13]  J. Woodhead A simple method for obtaining highly accurate Pb isotope data by MC-ICP-MS , 2002 .

[14]  D. Rickard,et al.  Determination of natural Cu-isotope variation by plasma-source mass spectrometry: implications for use as geochemical tracers , 2000 .

[15]  Francis Albarède,et al.  Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry , 1999 .

[16]  D. J. Douglas,et al.  Nonspectroscopic interelement interferences in inductively coupled plasma mass spectrometry , 1988 .

[17]  S. S. Goldich Natural Variations in the Abundance Ratio and the , 1965 .

[18]  S. Russell,et al.  High-precision Cu and Zn isotope analysis by plasma source mass spectrometry: Part 2. Correcting for mass discrimination effects , 2004 .

[19]  R. Barnes,et al.  Improving isotope ratio precision in inductivelycoupled plasma quadrupole mass spectrometry by common analyte internal standardization , 2001 .

[20]  M. Rehkämper,et al.  Investigation of matrix effects for Pb isotope ratio measurements by multiple collector ICP-MS: verification and application of optimized analytical protocols , 2000 .

[21]  K. Heumann,et al.  Precision and accuracy in isotope ratio measurements by plasma source mass spectrometry , 1998 .