Thermal and resonance neutrons generated by various electron and X-ray therapeutic beams from medical linacs installed in polish oncological centers.

BACKGROUND High-energy photon and electron therapeutic beams generated in medical linear accelerators can cause the electronuclear and photonuclear reactions in which neutrons with a broad energy spectrum are produced. A low-energy component of this neutron radiation induces simple capture reactions from which various radioisotopes originate and in which the radioactivity of a linac head and various objects in the treatment room appear. AIM The aim of this paper is to present the results of the thermal/resonance neutron fluence measurements during therapeutic beam emission and exemplary spectra of gamma radiation emitted by medical linac components activated in neutron reactions for four X-ray beams and for four electron beams generated by various manufacturers' accelerators installed in typical concrete bunkers in Polish oncological centers. MATERIALS AND METHODS The measurements of neutron fluence were performed with the use of the induced activity method, whereas the spectra of gamma radiation from decays of the resulting radioisotopes were measured by means of a portable high-purity germanium detector set for field spectroscopy. RESULTS The fluence of thermal neutrons as well as resonance neutrons connected with the emission of a 20 MV X-ray beam is ∼10(6) neutrons/cm(2) per 1 Gy of a dose in water at a reference depth. It is about one order of magnitude greater than that for the 15 MV X-ray beams and about two orders of magnitude greater than for the 18-22 MeV electron beams regardless of the type of an accelerator. CONCLUSION The thermal as well as resonance neutron fluence depends strongly on the type and the nominal potential of a therapeutic beam. It is greater for X-ray beams than for electrons. The accelerator accessories and other large objects should not be stored in a treatment room during high-energy therapeutic beam emission to avoid their activation caused by thermal and resonance neutrons. Half-lives of the radioisotopes originating from the simple capture reaction (n,γ) (from minutes to hours) are long enough to accumulate radioactivity of components of the accelerator head. The radiation emitted by induced radioisotopes causes the additional doses to staff operating the accelerators.

[1]  H. Vega-Carrillo,et al.  Photoneutron spectra around an 18 MV LINAC , 2011 .

[2]  Björn Poppe,et al.  Activation processes in a medical linear accelerator and spatial distribution of activation products , 2006, Physics in medicine and biology.

[3]  W. Zipper,et al.  Thermal and epithermal neutrons in the vicinity of the Primus Siemens biomedical accelerator , 2005 .

[4]  A. Mesbahi,et al.  A review on photoneutrons characteristics in radiation therapy with high-energy photon beams. , 2010, Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology.

[5]  David S Followill,et al.  Out-of-field photon and neutron dose equivalents from step-and-shoot intensity-modulated radiation therapy. , 2005, International journal of radiation oncology, biology, physics.

[6]  L. Pan,et al.  Thermal neutron fluence in a treatment room with a Varian linear accelerator at a medical university hospital , 2011 .

[7]  H. Richter,et al.  Induced Radioactive Potential for a Medical Accelerator , 2002, Health physics.

[8]  W. Price,et al.  Nuclear Radiation Detection , 1964 .

[9]  Danas Ridikas,et al.  Photonuclear Physics in Radiation Transport—III: Actinide Cross Sections and Spectra , 2006 .

[10]  A. Esposito,et al.  Determination of the neutron spectra around an 18 MV medical LINAC with a passive Bonner sphere spectrometer based on gold foils and TLD pairs , 2008 .

[11]  Roger C. Lee,et al.  A Distributed Processing Data Acquisition System at Brookhaven National Laboratory , 1979, IEEE Transactions on Nuclear Science.

[12]  K. Kase,et al.  Neutron sources in the Varian Clinac 2100C/2300C medical accelerator calculated by the EGS4 code. , 1997, Health physics.

[13]  P. Andreo,et al.  Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water , 2001 .

[14]  P. Ziemer,et al.  Health Physics Aspects of Neutron Activated Components in a Linear Accelerator , 2004, Health physics.

[15]  A. X. Silva,et al.  A study of neutron spectra from medical linear accelerators. , 2005, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[16]  R. Macklin,et al.  RESONANCE CAPTURE INTEGRALS , 1956 .

[17]  K. Polaczek-Grelik,et al.  Correlation between radioactivity induced inside the treatment room and the undesirable thermal/resonance neutron radiation produced by linac. , 2008, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[18]  Patrick Talou,et al.  Evaluation and Propagation of the 239Pu Fission Cross-Section Uncertainties Using a Monte Carlo Technique , 2006 .

[19]  Mark B. Chadwick,et al.  Status of the photonuclear activation file: Reaction cross-sections, fission fragments and delayed neutrons , 2006 .

[20]  B. L. Berman,et al.  Atlas of photoneutron cross sections obtained with monoenergetic photons. Second edition , 1974 .

[21]  Bcru Secretariat,et al.  British Committee on Radiation Units and Measurements: Advice on the Implications of the Conversion Coefficients for External Radiations Published in ICRP Publication 74 and in ICRU 57 , 1997 .

[22]  R. Gehrke Gamma-ray spectrometry in the environment , 1996 .

[23]  P. Mcginley,et al.  Air activation produced by high-energy medical accelerators. , 1983, Medical physics.

[24]  V. Lacoste,et al.  Experimental characterization of the neutron spectra generated by a high-energy clinical LINAC , 2011 .

[25]  K. Polaczek-Grelik,et al.  Background Neutron Radiation in the Vicinity of Varian Clinac-2300 Medical Accelerator Working in the 20 MV Mode , 2006 .

[26]  K. Polaczek-Grelik,et al.  Undesirable nuclear reactions and induced radioactivity as a result of the use of the high-energy therapeutic beams generated by medical linacs. , 2007, Radiation protection dosimetry.

[27]  G. Molnár Table of isotopes, 8th edn , 1998 .