Voltage Distribution and Flashover Performance of 220 kV Composite Insulators under Different Icing Conditions

Composite insulators are widely used in modern power systems to provide electrical insulation and mechanical support for transmission lines and substations. However, the insulation strength will decrease greatly under the combined conditions of ice-covering and contamination, and icing flashovers may take place under these serious conditions. In this paper, AC flashover tests of different artificially ice-covered 220 kV composite insulators were carried out in a multi-function artificial climate chamber under energized ice accumulation conditions. The test results indicate that, with the increasing of ice thickness, the flashover voltages decrease and tend to saturation. The icing flashover voltages can be increased by adding booster sheds, but excessive booster sheds can lead to lower flashover voltages under heavy icing conditions. The voltage distributions of the iced insulators were measured using experimental methods. The results show that, the air gaps withstand most of the applied voltage. The zinc oxide (ZnO) resistors that are contained in the insulators can influence the voltage distributions of the iced insulators, but have little affect on the icing flashover voltages. The work done in this paper can provide reference for the design and type selection of outdoor composite insulators in cold climate regions.

[1]  Jun Zhou,et al.  Ice flashover performance and its characterization parameter of composite insulator with booster sheds , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[2]  M. Farzaneh,et al.  Dimensioning of booster sheds for icing protection of post station insulators , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[3]  Qin Hu,et al.  Effects of shed configuration on AC flashover performance of ice-covered composite long-rod insulators , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[4]  Jianlin Hu,et al.  DC Flashover Performance of Ice-Covered Composite Insulators with Parallel Air Gaps , 2015 .

[5]  Qin Hu,et al.  Comparison of AC icing flashover performances of 220 kV composite insulators with different shed configurations , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  Qing Yang,et al.  Electrical Circuit Flashover Model of Polluted Insulators under AC Voltage Based on the Arc Root Voltage Gradient Criterion , 2012 .

[7]  R. E. Koch,et al.  Design of Zinc Oxide Transmission Line Arresters for Application on 138 kV Towers , 1985, IEEE Power Engineering Review.

[8]  M. Farzaneh,et al.  Empirical flashover model of EHV post insulators based on ISP parameter in cold environments , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[9]  Caixin Sun,et al.  Model for Predicting DC Flashover Voltage of Pre-Contaminated and Ice-Covered Long Insulator Strings under Low Air Pressure , 2011 .

[10]  M. Farzaneh,et al.  Role of air gaps on AC withstand voltage of an ice-covered insulator string , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.

[11]  M. Farzaneh,et al.  Flashover performance of ice-covered post insulators with booster sheds using experiments and partial arc modeling , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[12]  M. Farzaneh,et al.  Influence of air gaps on the DC withstand voltage of ice-covered UHV insulators , 2012, 2012 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.

[13]  Caixin Sun,et al.  DC Flashover Performance of Various Types of Ice-Covered Insulator Strings under Low Air Pressure , 2012 .

[14]  Yi Hu,et al.  Icing flashover characteristics and discharge process of 500 kV AC transmission line suspension insulator strings , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[15]  M. Farzaneh,et al.  Dynamic modeling of AC multiple ARCS of EHV post station insulators covered with ice , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[16]  Jun Zhou,et al.  Flashover Performance of HVDC Iced Insulator Strings , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[17]  Weiping Zhao,et al.  Simulation of Contamination Deposition on Typical Shed Porcelain Insulators , 2017 .

[18]  M. Farzaneh,et al.  Parametric studies and improved hypothesis of booster-shed effects on post insulators under heavy icing conditions , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[19]  Jianlin Hu,et al.  Electrical performance of 330-kV composite insulators with different shed configurations under icing conditions , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[20]  Qin Hu,et al.  Influences of grading ring arrangement on AC flashover performance of 220 KV ice-covered composite insulators , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[21]  M. Farzaneh,et al.  Study of discharge in air from the tip of an icicle , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[22]  Masoud Farzaneh,et al.  Nonlinear characteristics of leakage current for flashover monitoring of ice-covered suspension insulators , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[23]  Jiazheng Lu,et al.  Simulation and experiment of a composite insulator with lightning protection and icing flashover prevention , 2014, 2014 International Conference on Lightning Protection (ICLP).

[24]  M. Farzaneh,et al.  Flashover problems caused by ice build up on insulators , 1995 .

[25]  M. Farzaneh,et al.  AC flashover performance of insulators covered with artificial ice , 1995 .

[26]  M. Farzaneh,et al.  Application of Dynamic Model to Flashover of Ice-covered Insulators , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[27]  Jianchun Wei,et al.  Natural Contamination and Surface Flashover on Silicone Rubber Surface under Haze–Fog Environment , 2017 .

[28]  M. Farzaneh,et al.  Study of the Development of Positive Streamers Along an Ice Surface , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[29]  M. Farzaneh,et al.  Dynamic modeling of DC arc discharge on ice surfaces , 2003 .

[30]  M. Farzaneh,et al.  Equivalent surface conductivity of ice accumulated on insulators during development of AC and DC flashovers arcs , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.