Synthetic Aperture Focusing for Multi-Covariate Imaging of Sub-Resolution Targets

Coherence-based imaging methods suffer from reduced image quality outside the depth of field for focused ultrasound transmissions. Synthetic aperture methods can extend the depth of field by coherently compounding time-delayed echo data from multiple transmit events. Recently, our group has presented the Multi-covariate Imaging of Sub-resolution Targets (MIST), an estimation-based method to image the statistical properties of diffuse targets. MIST has demonstrated improved image quality over conventional delay-and-sum, but like many coherence-based imaging methods, suffers from limited depth of field artifacts. This article applies synthetic aperture focusing to MIST, which is evaluated using focused, plane-wave, and diverging-wave transmit geometries. Synthetic aperture MIST is evaluated in simulation, phantom, and in vivo applications, demonstrating consistent improvements in contrast-to-noise ratio (CNR) over conventional dynamic receive MIST outside the transmit depth of field, with approximately equivalent results between synthetic transmit geometries. In vivo synthetic aperture MIST images demonstrated 16.8 dB and 16.6% improvements in contrast and CNR, respectively, over dynamic receive MIST images, as well as 17.4 dB and 32.3% improvements over synthetic aperture B-Mode. MIST performance is characterized in the space of plane-wave imaging, where the total plane-wave count is reduced through coarse angular sampling or total angular span. Simulation and experimental results indicate wide applicability of MIST to synthetic aperture imaging methods.

[1]  J. Greenleaf,et al.  Nondiffracting X waves-exact solutions to free-space scalar wave equation and their finite aperture realizations , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  J. A. Hossack Extended focal depth imaging for medical ultrasound , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[3]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[4]  J. Camacho,et al.  Phase Coherence Imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  Pai-Chi Li,et al.  Adaptive imaging using the generalized coherence factor , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Jørgen Arendt Jensen,et al.  Tissue harmonic synthetic aperture ultrasound imaging. , 2014, The Journal of the Acoustical Society of America.

[7]  Nick Bottenus Recovery of the Complete Data Set From Focused Transmit Beams , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[8]  J.G. Miller,et al.  Spatial coherence of the nonlinearly generated second harmonic portion of backscatter for a clinical imaging system , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  Giovanni Magenes,et al.  The Delay Multiply and Sum Beamforming Algorithm in Ultrasound B-Mode Medical Imaging , 2015, IEEE Transactions on Medical Imaging.

[10]  Svetoslav Ivanov Nikolov,et al.  Virtual ultrasound sources in high-resolution ultrasound imaging , 2002, SPIE Medical Imaging.

[11]  Richard W. Prager,et al.  High-Resolution Ultrasound Imaging With Unified Pixel-Based Beamforming , 2016, IEEE Transactions on Medical Imaging.

[12]  M. Fink,et al.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  Matthew R. Morgan,et al.  Speckle coherence of piecewise-stationary stochastic targets. , 2019, Journal of the Acoustical Society of America.

[14]  Mickael Tanter,et al.  Ultrafast imaging in biomedical ultrasound , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[15]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Chuck Bradley Retrospective Transmit Beamformation ACUSON SC 2000 Volume Imaging Ultrasound System , 2008 .

[17]  Yangmo Yoo,et al.  Synthetic aperture imaging in breast ultrasound: a preliminary clinical study. , 2012, Academic radiology.

[18]  M. Bae,et al.  A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems. , 2000, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[19]  Alessandro Stuart Savoia,et al.  Depth‐of‐field enhancement in Filtered‐Delay Multiply and Sum beamformed images using Synthetic Aperture Focusing , 2017, Ultrasonics.

[20]  Jeremy J Dahl,et al.  Angular coherence in ultrasound imaging: Theory and applications. , 2017, The Journal of the Acoustical Society of America.

[21]  Gregg E Trahey,et al.  Multi-covariate Imaging of Sub-resolution Targets , 2019, IEEE Transactions on Medical Imaging.

[22]  Jørgen Arendt Jensen,et al.  Synthetic aperture ultrasound imaging. , 2006, Ultrasonics.

[23]  M L Li,et al.  Filter-Based Synthetic Transmit and Receive Focusing , 2001, Ultrasonic imaging.

[24]  M O'Donnell,et al.  Retrospective dynamic transmit focusing. , 1995, Ultrasonic imaging.

[25]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[26]  Kaare Brandt Petersen,et al.  The Matrix Cookbook , 2006 .

[27]  Pai-Chi Li,et al.  Improved synthetic aperture focusing technique with applications in high-frequency ultrasound imaging , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[28]  G. E. Trahey,et al.  Short-lag spatial coherence of backscattered echoes: imaging characteristics , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  Ole Marius Hoel Rindal,et al.  Signal Coherence and Image Amplitude With the Filtered Delay Multiply and Sum Beamformer , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[30]  Ole Marius Hoel Rindal,et al.  The Effect of Dynamic Range Alterations in the Estimation of Contrast , 2019, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[31]  Roger Zemp,et al.  Imaging with unfocused regions of focused ultrasound beams. , 2007, The Journal of the Acoustical Society of America.

[32]  Gregg E. Trahey,et al.  Synthetic aperture focusing for short-lag spatial coherence imaging , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[33]  Hiroshi Kanai,et al.  High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming , 2011, Journal of Medical Ultrasonics.

[34]  M. O'Donnell,et al.  Synthetic aperture imaging for small scale systems , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[35]  W.D. O'Brien,et al.  Synthetic aperture techniques with a virtual source element , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[36]  Nick Bottenus Comparison of virtual source synthetic aperture beamforming with an element-based model. , 2018, The Journal of the Acoustical Society of America.

[37]  Raoul Mallart,et al.  The van Cittert–Zernike theorem in pulse echo measurements , 1991 .