Simulation of Muscle-Based Orofacial Movement Dynamics using a Muscle Activation Dependent Varying Constitutive Law

This paper presents a dynamic biomechanical model of the face. It is implemented with a finite element method in the ANSYS software environment. A three layered mesh adapted to the description of the complex face muscles' courses have been defined. Soft tissues are modelled using a hyperelastic law. The variations of muscle tissues' mechanical properties associated with muscle activation are functionally accounted for and their influence on facial mimics and movements are

[1]  Yohan Payan,et al.  A Continuous Biomechanical Model of the Face: A Study of Muscle Coordination for Speech Lip Gestures , 2008 .

[2]  P. Blanton,et al.  Electromyographic Analysis of the Buccinator Muscle , 1970, Journal of dentistry research.

[3]  Ronald Fedkiw,et al.  Creating and simulating skeletal muscle from the visible human data set , 2005, IEEE Transactions on Visualization and Computer Graphics.

[4]  Ronald Fedkiw,et al.  Eurographics/ Acm Siggraph Symposium on Computer Animation (2006) Simulating Speech with a Physics-based Facial Muscle Model , 2022 .

[5]  B. Koopman,et al.  Three-dimensional finite element modeling of skeletal muscle using a two-domain approach: linked fiber-matrix mesh model. , 2001, Journal of biomechanics.

[6]  Victor Ng-Thow-Hing,et al.  Application-Specific Muscle Representations , 2002, Graphics Interface.

[7]  Yohan Payan,et al.  Patient specific finite element model of the face soft tissues for computer-assisted maxillofacial surgery , 2003, Medical Image Anal..

[8]  F. Zajac Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. , 1989, Critical reviews in biomedical engineering.

[9]  Jacques Ohayon,et al.  Transmission of Mechanical Stresses within the Cytoskeleton of Adherent Cells: A Theoretical Analysis Based on a Multi-Component Cell Model , 2004, Acta biotheoretica.

[10]  R. Wilhelms-Tricarico Physiological modeling of speech production: methods for modeling soft-tissue articulators. , 1995, The Journal of the Acoustical Society of America.

[11]  Bruce Elliot Hirsch,et al.  Gray’s Anatomy: The Anatomical Basis of Clinical Practice , 2009 .

[12]  Ronald Fedkiw,et al.  Automatic determination of facial muscle activations from sparse motion capture marker data , 2005, ACM Trans. Graph..

[13]  Yohan Payan,et al.  A 3D biomechanical vocal tract model to study speech production control: How to take into account the gravity? , 2007, physics/0701285.

[14]  Evgeny Gladilin,et al.  A Framework for Biomechanical Simulation of Cranio-Maxillofacial Surgery Interventions , 2004, ISMS.

[15]  Yohan Payan,et al.  Synthesis of V-V sequences with a 2D biomechanical tongue model controlled by the Equilibrium Point Hypothesis , 1997, Speech Commun..

[16]  J D Humphrey,et al.  Constitutive Relations and Finite Deformations of Passive Cardiac Tissue II: Stress Analysis in the Left Ventricle , 1989, Circulation research.

[17]  K G Munhall,et al.  A model of facial biomechanics for speech production. , 1999, The Journal of the Acoustical Society of America.

[18]  C. G. Lyons,et al.  A validated model of passive muscle in compression. , 2006, Journal of biomechanics.

[19]  J. Weiss,et al.  Finite element implementation of incompressible, transversely isotropic hyperelasticity , 1996 .

[20]  Thomas A. McMahon,et al.  Muscles, Reflexes, and Locomotion , 1984 .

[21]  S. Delp,et al.  A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii. , 2005, Journal of biomechanics.

[22]  Demetri Terzopoulos,et al.  Realistic modeling for facial animation , 1995, SIGGRAPH.

[23]  M. GerardJ. Non linear elastic properties of the lingual and facial tissues assessed by indentation technique . Application to the biomechanics of speech production , 2005 .

[24]  D. O'Shaughnessy A study of French vowel and consonant durations , 1981 .