Response control of a large transmission tower-line system under seismic excitations using friction dampers

The transmission tower-line system is widely used in electric infrastructures across the world and generally possesses a small stiffness and low structural damping. The excessive vibration of a transmission tower-line system subjected to seismic excitations may induce a structural damage or failure. To avoid the excessive vibration under strong earthquakes, a large transmission tower-line system requires some measures to abate their dynamic responses. Friction damper is a solution to realize the response control of a transmission tower-line system. In this regard, the response mitigation and performance assessment on a transmission tower-line system with friction dampers under strong earthquakes are actively carried out in this study. The analytical model of a transmission line is proposed based on Hamilton’s variational statement of dynamics and Lagrange’s formulation. A two-dimensional lumped mass model of a transmission tower is developed for the dynamic analysis by simplifying the three-dimensional finite element model. The mechanical model of a friction damper is established by considering the effect of damper axial stiffness. The equations of motion and dynamic analytical method of a transmission tower-line system without/with friction dampers subjected to seismic excitations are proposed. In addition, the approach for assessing energy responses of a transmission tower-line system without/with friction dampers subjected to seismic excitations is also developed. A real transmission tower-line system is taken as an example to examine the feasibility of the proposed control approach. The parametric study is conducted to investigate the effects of damper control force, damper stiffness, earthquake intensity, and damper location. The made observations demonstrate that the implementation of friction dampers in a transmission tower-line system can substantially suppress the seismic responses with optimal damper parameters.

[1]  Hong-Nan Li,et al.  Simplified models and experimental verification for coupled transmission tower–line system to seismic excitations , 2005 .

[2]  Hong-Nan Li,et al.  Robustness study of the pounding tuned mass damper for vibration control of subsea jumpers , 2015 .

[3]  Ronaldo C. Battista,et al.  Dynamic behavior and stability of transmission line towers under wind forces , 2003 .

[4]  Bo Chen,et al.  CONTROL OF WIND-INDUCED RESPONSE OF TRANSMISSION TOWER-LINE SYSTEM BY USING MAGNETORHEOLOGICAL DAMPERS , 2009 .

[5]  Gangbing Song,et al.  Vibration control of a traffic signal pole using a pounding tuned mass damper with viscoelastic materials (II): experimental verification , 2015 .

[6]  Phill-Seung Lee,et al.  Elastoplastic large deformation analysis of a lattice steel tower structure and comparison with full-scale tests , 2007 .

[7]  Li Hong-nan Analysis and Optimization Control of Wind-induced Dynamic Response for High-voltage Transmission Tower-line System , 2008 .

[8]  Li Li,et al.  Error Assessment for Spectral Representation Method in Wind Velocity Field Simulation , 2010 .

[9]  Robert E. Bachman,et al.  The Use of the Energy Dissipating Restraint for Seismic Hazard Mitigation , 1993 .

[10]  Y. L. Xu,et al.  A new damage index for detecting sudden change of structural stiffness , 2007 .

[11]  Marina Schroder,et al.  Structural Control Past Present And Future , 2016 .

[12]  Junji Maeda,et al.  In-plane dynamic interaction between a tower and conductors at lower frequencies , 1992 .

[13]  Yue Zheng,et al.  Conditional simulation of spatially variable seismic ground motions based on evolutionary spectra , 2012 .

[14]  Bo Chen,et al.  Dynamic Responses and Vibration Control of the Transmission Tower-Line System: A State-of-the-Art Review , 2014, TheScientificWorldJournal.

[15]  Cedric Marsh,et al.  Seismic Response of Friction Damped Braced Frames , 1982 .

[16]  Leon Kempner,et al.  Cross‐Rope Transmission Tower‐Line Dynamic Analysis , 1984 .

[17]  Jiannong Cao,et al.  Design and implementation of distributed algorithms for WSN-based structural health monitoring , 2009, Int. J. Sens. Networks.

[18]  S. Ohkubo,et al.  Optimal synthesis method for transmission tower truss structures subjected to static and seismic loads , 2004 .

[19]  Bo Chen,et al.  Performance Evaluation on Transmission Tower-Line System with Passive Friction Dampers Subjected to Wind Excitations , 2015 .

[20]  Jagmohan Humar,et al.  Dynamic of structures , 1989 .

[21]  Cedric Marsh,et al.  RESPONSE OF FRICTION DAMPED BRACED FRAMES , 1982 .

[22]  Wl L. Qu,et al.  Active/robust moment controllers for seismic response control of a large span building on top of ship lift towers , 2003 .