Mathematical modeling of laser lipolysis

Background and ObjectivesLiposuction continues to be one of the most popular procedures performed in cosmetic surgery. As the public's demand for body contouring continues, laser lipolysis has been proposed to improve results, minimize risk, optimize patient comfort, and reduce the recovery period. Mathematical modeling of laser lipolysis could provide a better understanding of the laser lipolysis process and could determine the optimal dosage as a function of fat volume to be removed.Study design/Materials and MethodsAn Optical-Thermal-Damage Model was formulated using finite-element modeling software (Femlab 3.1, Comsol Inc). The general model simulated light distribution using the diffusion approximation of the transport theory, temperature rise using the bioheat equation and laser-induced injury using the Arrhenius damage model. Biological tissue was represented by two homogenous regions (dermis and fat layer) with a nonlinear air-tissue boundary condition including free convection.Video recordings were used to gain a better understanding of the back and forth movement of the cannula during laser lipolysis in order to consider them in our mathematical model. Infrared video recordings were also performed in order to compare the actual surface temperatures to our calculations. The reduction in fat volume was determined as a function of the total applied energy and subsequently compared to clinical data reported in the literature.ResultsIn patients, when using cooled tumescent anesthesia, 1064 nm Nd:YAG laser or 980 nm diode laser: (6 W, back and forth motion: 100 mm/s) give similar skin surface temperature (max: 41°C). These measurements are in accordance with those obtained by mathematical modeling performed with a 1 mm cannula inserted inside the hypodermis layer at 0.8 cm below the surface. Similarly, the fat volume reduction observed in patients at 6-month follow up can be determined by mathematical modeling. This fat reduction depends on the applied energy, typically 5 cm3 for 3000 J. At last, skin retraction was observed in patients at 6-month follow up. This observation can be easily explained by mathematical modeling showing that the temperature increase inside the lower dermis is sufficient (48–50°C) to induce skin tighteningDiscussion and ConclusionLaser lipolysis can be described by a theoretical model. Fat volume reduction observed in patients is in accordance with model calculations. Due to heat diffusion, temperature elevation is also produced inside the lower reticular dermis. This interesting observation can explain remodeling of the collagenous tissue, with clinically evident skin tightening.In conclusion, while the heat generated by interstitial laser irradiation provides stimulate lipolysis of the fat cells, the collagen and elastin are also stimulated resulting in a tightening in the skin. This mathematical model should serve as a useful tool to simulate and better understand the mechanism of action of the laser lipolysis

[1]  Tianhong Dai,et al.  Comparison of human skin opto-thermal response to near-infrared and visible laser irradiations: a theoretical investigation. , 2004, Physics in medicine and biology.

[2]  Janko F Verhey,et al.  A finite element method model to simulate laser interstitial thermo therapy in anatomical inhomogeneous regions. , 2005 .

[3]  Ernest G. Cravalho,et al.  Time Progression of Hemolysis of Erythrocyte Populations Exposed to Supraphysiological Temperatures , 1979 .

[4]  Michael C. Kolios,et al.  The effects of dynamic optical properties during interstitial laser photocoagulation. , 2000, Physics in medicine and biology.

[5]  A. Welch,et al.  Infrared imaging of 2-D temperature distribution during cryogen spray cooling. , 2002, Journal of biomechanical engineering.

[6]  L. O. Svaasand,et al.  Influence of nozzle‐to‐skin distance in cryogen spray cooling for dermatologic laser surgery , 2001, Lasers in surgery and medicine.

[7]  Joseph P. Hunstad,et al.  Progress report on multicenter study of laser-assisted liposuction , 1995, Aesthetic Plastic Surgery.

[8]  Elena Salomatina,et al.  Optical properties of normal and cancerous human skin in the visible and near-infrared spectral range. , 2006, Journal of biomedical optics.

[9]  R. Geronemus,et al.  Laser Lipolysis Using a Novel 1,064 nm Nd: YAG Laser , 2006, Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.].

[10]  L. Reinisch,et al.  Laser treatment of solar elastosis with epithelial preservation , 1998, Lasers in surgery and medicine.

[11]  S Mordon,et al.  In vivo experimental evaluation of skin remodeling by using an Er:Glass laser with contact cooling , 2000, Lasers in surgery and medicine.

[12]  L. Noronha,et al.  Analysis of Laser Lipolysis Effects on Human Tissue Samples Obtained from Liposuction , 2005, Aesthetic Plastic Surgery.

[13]  Sharon Thomsen,et al.  Rate Process Analysis of Thermal Damage , 1995 .

[14]  A. Goldman Submental Nd:Yag laser‐assisted liposuction , 2006, Lasers in surgery and medicine.

[15]  L. Canta,et al.  Laser Lipolysis: Flaccidity Under Control , 2002, Aesthetic Plastic Surgery.

[16]  P. Andrades,et al.  A Prospective, Randomized, Double-Blind, Controlled Clinical Trial Comparing Laser-Assisted Lipoplasty with Suction-Assisted Lipoplasty , 2006, Plastic and reconstructive surgery.

[17]  Olaf Minet,et al.  Specific heat capacities of human and animal tissues , 1996, European Conference on Biomedical Optics.

[18]  Moriaki Wakaki,et al.  Histologic evaluation of the pulsed Nd:YAG laser for laser lipolysis , 2005, Lasers in surgery and medicine.

[19]  Serge Mordon,et al.  Histologic evaluation of laser lipolysis: pulsed 1064-nm Nd:YAG laser versus cw 980-nm diode laser. , 2007, Aesthetic surgery journal.

[20]  Moriaki Wakaki,et al.  Histologic and photonic evaluation of a pulsed Nd:YAG laser for ablation of subcutaneous adipose tissue. , 2006, The Tokai journal of experimental and clinical medicine.

[21]  A. N. Bashkatov,et al.  Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000 nm , 2005 .