Quantitative contrast ultrasound analysis of renal perfusion in normal dogs.

Eight normal dogs with no evidence of renal disease, weighing between 8 and 25 kg were imaged using contrast harmonic ultrasound after injection of a microbubble contrast medium. All dogs received three separate bolus injections of 0.05 ml of commercial contrast medium (Definity). Time/mean pixel value (MPV) curves were generated for selected regions in the cortex and medulla of the left kidney in each dog. Upslope, downslope, baseline, peak intensity, and time to peak were calculated for each zone. For a bolus injection, within the renal cortex (averaging all subjects) the upslope was 7.4 +/- 1.5 MPV/s, downslope was -0.4 +/- .2 MPV/s, baseline was 66.8 +/- 9.3 MPV, peak was 103.6 +/- 8.2 MPV, time to peak (from injection) was 12.8 +/- 5.3 s and from time of contrast medium reaching the kidney was 5.1 +/- 2.0 s. Within the renal medulla (averaging all subjects), upslope was 2.8 +/- 1.7 MPV/s, downslope was -0.3 +/- .2 MPV/s, baseline was 39.3 +/- 6.0 MPV, peak was 65.2 +/- 14.3 MPV, time to peak from injection was 20.9 +/- 6.4 s and from time of contrast reaching the kidney was 11.6 +/- 4.1 s. These baseline data may prove useful in the evaluation of dogs with diffuse disease or vascular compromise.

[1]  T. Kim,et al.  Benign Liver Masses: Imaging With Microbubble Contrast Agents , 2006, Ultrasound quarterly.

[2]  M. Kjelgaard‐Hansen,et al.  Contrast-enhanced ultrasonography in normal canine liver. Evaluation of imaging and safety parameters. , 2005, Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association.

[3]  J. Matheson,et al.  Contrast harmonic ultrasound of spontaneous liver nodules in 32 dogs. , 2004, Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association.

[4]  J. Zagzebski,et al.  Quantitative contrast harmonic ultrasound imaging of normal canine liver. , 2003, Veterinary Radiology & Ultrasound.

[5]  J. Matheson,et al.  Use of contrast harmonic ultrasound for the diagnosis of congenital portosystemic shunts in three dogs. , 2003, Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association.

[6]  Pai-Chi Li,et al.  Effects of Transmit Focusing on Finite Amplitude Distortion Based Second Harmonic Generation , 1999, Ultrasonic imaging.

[7]  G. Steinbach,et al.  Assessment of liver and kidney enhancement with a perfluorocarbon vapor-stabilized US contrast agent. , 1999, Academic radiology.

[8]  C. Sirlin,et al.  Effect of acquisition rate on liver and portal vein enhancement with microbubble contrast. , 1999, Ultrasound in medicine & biology.

[9]  S. Taylor-Robinson,et al.  Liver vascular transit time analyzed with dynamic hepatic venography with bolus injections of an US contrast agent: early experience in seven patients with metastases. , 1998, Radiology.

[10]  D. Miller Frequency relationships for ultrasonic activation of free microbubbles, encapsulated microbubbles, and gas-filled micropores. , 1998, The Journal of the Acoustical Society of America.

[11]  T. Porter,et al.  Increased ultrasound contrast and decreased microbubble destruction rates with triggered ultrasound imaging. , 1996, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[12]  P. Burns Harmonic imaging with ultrasound contrast agents. , 1996, Clinical radiology.