Limit Operating Temperature in Polymer Electrolyte Membrane Fuel Cells

In this research, a control technique for polymer electrolyte membrane (PEM) fuel cells based on the limit operating temperature is introduced. The limit operating temperature is the highest temperature in which the PEM fuel cell can operate, preserving a recommended relative humidity and air stoichiometry. The operating temperature influences the fuel cell voltage; the higher the temperature, the better the voltage. A PEM fuel cell model is applied to analyze the evolution and dependence among the variables. The tests were performed considering two situations: PEM fuel cells without extra humidification and PEM fuel cells with an external humidifier. Also, the influence of humidity and temperature of the input air can be analyzed separately. The results show that the limit temperature strategy is stable and consistent under different operational conditions such as different load requirements and presence/absence of extra humidification.

[1]  Alexander Wokaun,et al.  Experimental investigation of coupling phenomena in polymer electrolyte fuel cell stacks , 2006 .

[2]  Keith Promislow,et al.  A simple, mathematical model of thermal coupling in fuel cell stacks , 2005 .

[3]  Belkacem Ould-Bouamama,et al.  Model based PEM fuel cell state-of-health monitoring via ac impedance measurements , 2006 .

[4]  M.G. Simoes,et al.  Sensitivity analysis of the modeling parameters used in Simulation of proton exchange membrane fuel cells , 2005, IEEE Transactions on Energy Conversion.

[5]  James Larminie,et al.  Fuel Cell Systems Explained , 2000 .

[6]  Christoph Ziegler,et al.  Transient Behavior of a Proton Exchange Membrane Fuel Cell under Dry Operation , 2006 .

[7]  Luciane Neves Canha,et al.  An electrochemical-based fuel-cell model suitable for electrical engineering automation approach , 2004, IEEE Transactions on Industrial Electronics.

[8]  Shanhai Ge,et al.  Liquid Water Formation and Transport in the PEFC Anode , 2007 .

[9]  Alexander Wokaun,et al.  In-Plane Effects in Large-Scale PEMFCs Model Formulation and Validation , 2006 .

[10]  H. Toghiani,et al.  Steady state and dynamic performance of proton exchange membrane fuel cells (PEMFCs) under various operating conditions and load changes , 2006 .

[11]  Keith Promislow,et al.  Electrical coupling in proton exchange membrane fuel cell stacks , 2005 .

[12]  B. Wetton,et al.  Flow distribution in proton exchange membrane fuel cell stacks , 2006 .

[13]  Luis A. M. Riascos,et al.  Relative humidity control in polymer electrolyte membrane fuel cells without extra humidification , 2008 .

[14]  Shimshon Gottesfeld,et al.  Electro-osmotic Drag of Water in Poly(perfluorosulfonic acid) Membranes , 2001 .

[15]  Marcelo Godoy Simões,et al.  On-line fault diagnostic system for proton exchange membrane fuel cells , 2008 .

[16]  M. Han,et al.  Guidelines for Stable Operation of a Polymer Electrolyte Fuel Cell with Self-Humidifying Membrane Electrolyte Assembly , 2007 .

[17]  James Larminie,et al.  Fuel Cell Systems Explained: Larminie/Fuel Cell Systems Explained , 2003 .

[18]  Alexander Wokaun,et al.  In-Plane Effects in Large-Scale PEFCs II. The Influence of Cooling Strategy on Cell Performance , 2006 .

[19]  R. O’Hayre,et al.  Fuel Cell Fundamentals , 2005 .

[20]  Q. Xin,et al.  PtTiO x / C Electrocatalysts with Improved Durability in H2 / O2 PEMFCs without External Humidification , 2008 .

[21]  Marcelo Godoy Simões,et al.  A Bayesian network fault diagnostic system for proton exchange membrane fuel cells , 2007 .

[22]  Felix N. Büchi,et al.  Operating Proton Exchange Membrane Fuel Cells Without External Humidification of the Reactant Gases Fundamental Aspects , 1997 .

[23]  In-Hwan Oh,et al.  A study on cathode structure and water transport in air-breathing PEM fuel cells , 2006 .

[24]  Jean St-Pierre,et al.  PEMFC In Situ Liquid-Water-Content Monitoring Status , 2007 .