Polymer electrolyte actuator with gold electrodes

A perfluorinated cation-exchange membrane plated with noble metals was found to bend with electric stimuli in water or a saline solution. The bent to anode is almost proportional to the applied voltage around 1.5 V, which is low enough to avoid electrolysis of water. The response is as quick as muscle. Composite of perfluorocarboxylic acid and electrodes gave larger displacement than that of perfluorosulfonic acid. Gold electrodes were deposited on the polymer electrolyte with large surface area by repeated plating, and showed larger displacement without gas evolution than platinum electrodes. Alkyl ammonium cation in the composite gave slower but larger displacement than alkali metal cations. The displacement of the strip of actuator in typical dimension of 0.2 mm thick and 10 mm long is more than 5 mm without gas evolution. A tubular actuator with four electrodes was fabricated with the newly developed components and bent more than 90 degree in 2 cm length to all directions.

[1]  B. Breslau,et al.  A Hydrodynamic Model for Electroosmosis , 1971 .

[2]  F. C. Wilson,et al.  The morphology in nafion† perfluorinated membrane products, as determined by wide- and small-angle x-ray studies , 1981 .

[3]  T. Springer,et al.  Water Uptake by and Transport Through Nafion® 117 Membranes , 1993 .

[4]  J. Hinatsu,et al.  Water Uptake of Perfluorosulfonic Acid Membranes from Liquid Water and Water Vapor , 1994 .

[5]  K. Oguro,et al.  Bending of Polyelectrolyte Membrane–Platinum Composites by Electric Stimuli I. Response Characteristics to Various Waveforms , 1995 .

[6]  Kazuhiro Kosuge,et al.  Micro catheter system with active guide wire , 1995, Proceedings of 1995 IEEE International Conference on Robotics and Automation.

[7]  G. Xie,et al.  Pumping Effects in Water Movement Accompanying Cation Transport Across Nafion 117 Membranes , 1996 .

[8]  M. Yoshitake,et al.  STUDIES OF PERFLUORINATED ION EXCHANGE MEMBRANES FOR POLYMER ELECTROLYTE FUEL CELLS , 1996 .

[9]  Shuxiang Guo,et al.  Development of underwater microrobot using ICPF actuator , 1998, Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146).

[10]  S. Sewa,et al.  Polymer actuator driven by ion current at low voltage, applied to catheter system , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.