Quantification of Right and Left Ventricular Function in Cardiac MR Imaging: Comparison of Semiautomatic and Manual Segmentation Algorithms

The purpose of this study was to evaluate the performance of a semiautomatic segmentation method for the anatomical and functional assessment of both ventricles from cardiac cine magnetic resonance (MR) examinations, reducing user interaction to a “mouse-click”. Fifty-two patients with cardiovascular diseases were examined using a 1.5-T MR imaging unit. Several parameters of both ventricles, such as end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF), were quantified by an experienced operator using the conventional method based on manually-defined contours, as the standard of reference; and a novel semiautomatic segmentation method based on edge detection, iterative thresholding and region growing techniques, for evaluation purposes. No statistically significant differences were found between the two measurement values obtained for each parameter (p > 0.05). Correlation to estimate right ventricular function was good (r > 0.8) and turned out to be excellent (r > 0.9) for the left ventricle (LV). Bland-Altman plots revealed acceptable limits of agreement between the two methods (95%). Our study findings indicate that the proposed technique allows a fast and accurate assessment of both ventricles. However, further improvements are needed to equal results achieved for the right ventricle (RV) using the conventional methodology.

[1]  D J Pennell,et al.  Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance. , 2000, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[2]  Christoph Butenweg,et al.  Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T , 2010, European Radiology.

[3]  Tae Hoon Kim,et al.  Evaluation of right ventricular volume and mass using retrospective ECG-gated cardiac multidetector computed tomography: comparison with first-pass radionuclide angiography , 2005, European Radiology.

[4]  Marco Das,et al.  Global left ventricular function in cardiac CT. Evaluation of an automated 3D region-growing segmentation algorithm , 2006, European Radiology.

[5]  P. Nihoyannopoulos,et al.  Anatomy, echocardiography, and normal right ventricular dimensions , 2006, Heart.

[6]  Raja Muthupillai,et al.  Evaluation of cardiac biventricular segmentation from multiaxis MRI data: A multicenter study , 2008, Journal of magnetic resonance imaging : JMRI.

[7]  James C Carr,et al.  ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Ra , 2006, Journal of the American College of Cardiology.

[8]  M. Oudkerk,et al.  Assessment of global left ventricular functional parameters: analysis of every second short-axis Magnetic Resonance Imaging slices is as accurate as analysis of consecutive slices , 2008, The International Journal of Cardiovascular Imaging.

[9]  P. Echávarri,et al.  Cuantificación de la función y masa ventricular con secuencias SSFP en tiempo real y respiración libre , 2008 .

[10]  Thoralf Niendorf,et al.  Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla—a pilot study , 2010, European Radiology.

[11]  T. Geva Repaired tetralogy of Fallot: the roles of cardiovascular magnetic resonance in evaluating pathophysiology and for pulmonary valve replacement decision support , 2011, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[12]  Michael Jerosch-Herold,et al.  Correlation of right ventricular ejection fraction and tricuspid annular plane systolic excursion in tetralogy of Fallot by magnetic resonance imaging , 2009, The International Journal of Cardiovascular Imaging.

[13]  S. Maderwald,et al.  Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine , 2010, European Radiology.

[14]  J. Francis,et al.  A comparison of visual and quantitative assessment of left ventricular ejection fraction by cardiac magnetic resonance , 2011, The International Journal of Cardiovascular Imaging.

[15]  Stefan Neubauer,et al.  Normal human left and right ventricular and left atrial dimensions using steady state free precession magnetic resonance imaging. , 2005, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[16]  Gorka Bastarrika,et al.  Quantification of left ventricular function and mass in cardiac Dual-Source CT (DSCT) exams: comparison of manual and semiautomatic segmentation algorithms , 2008, European Radiology.

[17]  N Hosten,et al.  Comparison of transthoracic three dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass. , 1997, Heart.

[18]  S. Plein,et al.  Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady‐state free precession imaging sequences , 2003, Journal of magnetic resonance imaging : JMRI.

[19]  Bob S. Hu,et al.  Single‐breathhold, four‐dimensional, quantitative assessment of LV and RV function using triggered, real‐time, steady‐state free precession MRI in heart failure patients , 2005, Journal of magnetic resonance imaging : JMRI.

[20]  Dudley J Pennell,et al.  Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance. , 2006, European heart journal.

[21]  Cristiana Corsi,et al.  Improved reproducibility of right ventricular volumes and function estimation from cardiac magnetic resonance images using level‐set models , 2007, Magnetic resonance in medicine.

[22]  Boudewijn P F Lelieveldt,et al.  Evaluation of a new method for automated detection of left ventricular boundaries in time series of magnetic resonance images using an Active Appearance Motion Model. , 2004, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[23]  C Baldy,et al.  Automated myocardial edge detection from breath-hold cine-MR images: evaluation of left ventricular volumes and mass. , 1994, Magnetic resonance imaging.

[24]  M. Friedrich,et al.  Comparison of long and short axis quantification of left ventricular volume parameters by cardiovascular magnetic resonance, with ex-vivo validation , 2011, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[25]  Caroline Petitjean,et al.  A review of segmentation methods in short axis cardiac MR images , 2011, Medical Image Anal..

[26]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[27]  Scott E. Umbaugh,et al.  Computer Vision and Image Processing: A Practical Approach Using CVIPTools , 1997 .

[28]  Francesco Sardanelli,et al.  Segmentation of cardiac cine MR images of left and right ventricles: Interactive semiautomated methods and manual contouring by two readers with different education and experience , 2008, Journal of magnetic resonance imaging : JMRI.

[29]  Carmel Hayes,et al.  Assessment of left ventricular function by breath‐hold cine MR imaging: Comparison of different steady‐state free precession sequences , 2005, Journal of magnetic resonance imaging : JMRI.

[30]  Miguel Souto,et al.  Semiautomatic quantification of left and right ventricular functions in magnetic resonance imaging , 2010, 2010 Computing in Cardiology.