Sliding Mode Control of Single-Phase UPS Inverters Using a Three-Level Hysteresis Switching Function

A new approach to the sliding mode control of single-phase UPS inverters is introduced in continuous-time. A three-level hysteresis switching function is used to directly control the inverter switches. The theoretical and predicted switching frequency expressions are given. The performance of the proposed control method has been tested through computer simulations using different loads (a load which draws a square-wave current, diode bridge rectifier load, and triac-controlled resistive load). Simulation results verify the correct operation of the proposed control approach. Also, the switching frequency prediction is seen to be quite accurate

[1]  M. Marchesoni,et al.  Experimental study of a power conditioning system using sliding mode control , 1996 .

[2]  A. Zuccato,et al.  An AC power supply with sliding-mode control , 1993 .

[3]  Yong Kang,et al.  Direct repetitive control of SPWM inverter for UPS purpose , 2003 .

[4]  Jian-Shiang Chen,et al.  UPS inverter design using discrete-time sliding-mode control scheme , 2002, IEEE Trans. Ind. Electron..

[5]  Chihchiang Hua,et al.  Two-level switching pattern deadbeat DSP controlled PWM inverter , 1995 .

[6]  John E. Quaicoe,et al.  Analysis and design of a multiple feedback loop control strategy for single-phase voltage-source UPS inverters , 1996 .

[7]  S. J. Chiang,et al.  Variable structure control of UPS inverters , 1998 .

[8]  Ying-Yu Tzou,et al.  Discrete sliding-mode control of a PWM inverter for sinusoidal output waveform synthesis with optimal sliding curve , 1996 .

[9]  Ying-Yu Tzou,et al.  High-performance programmable AC power source with low harmonic distortion using DSP-based repetitive control technique , 1997 .

[10]  Hasan Komurcugil,et al.  Control strategy for single-phase UPS inverters , 2003 .

[11]  C. Rech,et al.  A modified discrete control law for UPS applications , 2000, 2000 IEEE 31st Annual Power Electronics Specialists Conference. Conference Proceedings (Cat. No.00CH37018).

[12]  Atsuo Kawamura,et al.  Deadbeat control of PWM inverter with modified pulse patterns for uninterruptible power supply , 1988 .

[13]  N. Abdel-Rahim,et al.  Multiple feedback loop control strategy for single-phase voltage-source UPS inverter , 1994, Proceedings of 1994 Power Electronics Specialist Conference - PESC'94.

[14]  Hasan Komurcugil,et al.  Deadbeat control method for single-phase UPS inverters with compensation of computation delay , 1999 .

[15]  Robert D. Lorenz,et al.  Control topology options for single-phase UPS inverters , 1996, Proceedings of International Conference on Power Electronics, Drives and Energy Systems for Industrial Growth.