Comparison of four magnetic resonance methods for mapping small temperature changes

Non-invasive detection of small temperature changes (< 1 degree C) is pivotal to the further advance of regional hyperthermia as a treatment modality for deep-seated tumours. Magnetic resonance (MR) thermography methods are considered to be a promising approach. Four methods exploiting temperature-dependent parameters were evaluated in phantom experiments. The investigated temperature indicators were spin-lattice relaxation time T1, diffusion coefficient D, shift of water proton resonance frequency (water PRF) and resonance frequency shift of the methoxy group of the praseodymium complex (Pr probe). The respective pulse sequences employed to detect temperature-dependent signal changes were the multiple readout single inversion recovery (T One by Multiple Read Out Pulses; TOMROP), the pulsed gradient spin echo (PGSE), the fast low-angle shot (FLASH) with phase difference reconstruction, and the classical chemical shift imaging (CSI). Applying these sequences, experiments were performed in two separate and consecutive steps. In the first step, calibration curves were recorded for all four methods. In the second step, applying these calibration data, maps of temperature changes were generated and verified. With the equal total acquisition time of approximately 4 min for all four methods, the uncertainties of temperature changes derived from the calibration curves were less than 1 degree C (Pr probe 0.11 degrees C, water PRF 0.22 degrees C, D 0.48 degrees C and T1 0.93 degrees C). The corresponding maps of temperature changes exhibited slightly higher errors but still in the range or less than 1 degree C (0.97 degrees C, 0.41 degrees C, 0.70 degrees C, 1.06 degrees C respectively). The calibration results indicate the Pr probe method to be most sensitive and accurate. However, this advantage could only be partially transferred to the thermographic maps because of the coarse 16 x 16 matrix of the classical CSI sequence. Therefore, at present the water PRF method appears to be most suitable for MR monitoring of small temperature changes during hyperthermia treatment.

[1]  P. Wust,et al.  Non-invasive MR thermometry by 2D spectroscopic imaging of the Pr[MOE-DO3A] complex. , 1998, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[2]  M. Clouse,et al.  TmDOTP5−: A substance for NMR temperature measurements in vivo , 1996, Magnetic resonance in medicine.

[3]  K. Hynynen,et al.  Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beam , 1996, Magnetic resonance in medicine.

[4]  J V Hajnal,et al.  An evaluation of the effects of susceptibility changes on the water chemical shift method of temperature measurement in human peripheral muscle , 1996, Magnetic resonance in medicine.

[5]  P Wust,et al.  Simulation studies promote technological development of radiofrequency phased array hyperthermia. , 1996, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[6]  Enzo Terreno,et al.  A new ytterbium chelate as contrast agent in chemical shift imaging and temperature sensitive probe for MR spectroscopy , 1996, Magnetic resonance in medicine.

[7]  K. Roth,et al.  Noninvasive temperature measurement in Vivo using a temperature‐sensitive lanthanide complex and 1H magnetic resonance spectroscopy , 1996, Magnetic resonance in medicine.

[8]  K. Hynynen,et al.  Simultaneous magnetic resonance phase and magnitude temperature maps in muscle , 1996, Magnetic resonance in medicine.

[9]  H. Gudbjartsson,et al.  The rician distribution of noisy mri data , 1995, Magnetic resonance in medicine.

[10]  K. Kuroda,et al.  A precise and fast temperature mapping using water proton chemical shift , 1995, Magnetic resonance in medicine.

[11]  John De Poorter,et al.  Noninvasive MRI thermometry with the proton resonance frequency method: Study of susceptibility effects , 1995 .

[12]  M Deimling,et al.  Malignant liver tumors treated with MR imaging-guided laser-induced thermotherapy: technique and prospective results. , 1995, Radiology.

[13]  J. D. de Certaines,et al.  Measurements of the effect of storage at various temperatures on the T1 of ex vivo tissues. , 1995, Medical physics.

[14]  J. Poorter,et al.  Noninvasive MRI Thermometry with the Proton Resonance Frequency (PRF) Method: In Vivo Results in Human Muscle , 1995, Magnetic resonance in medicine.

[15]  F S Prato,et al.  A novel fast T1‐mapping method , 1994, Journal of magnetic resonance imaging : JMRI.

[16]  Angela Oatridge,et al.  Modeling and observation of temperature changes in Vivo using MRI , 1994, Magnetic resonance in medicine.

[17]  Kullervo Hynynen,et al.  MR temperature mapping of focused ultrasound surgery , 1994, Magnetic resonance in medicine.

[18]  A Oatridge,et al.  Further observations on the measurement of tissue T1 to monitor temperature in vivo by MRI , 1994, Magnetic resonance in medicine.

[19]  Eric Achten,et al.  The Proton-Resonance-Frequency-Shift Method Compared with Molecular Diffusion for Quantitative Measurement of Two-Dimensional Time-Dependent Temperature Distribution in a Phantom , 1994 .

[20]  P. Gowland,et al.  Accurate measurement of T1 in vivo in less than 3 seconds using echo‐planar imaging , 1993, Magnetic resonance in medicine.

[21]  W. J. Lorenz,et al.  Spin‐lattice relaxation time measurement by means of a TurboFLASH technique , 1993, Magnetic resonance in medicine.

[22]  W. Hull,et al.  A 1H‐NMR method for determining temperature in cell culture perfusion systems , 1993, Magnetic resonance in medicine.

[23]  P. Gowland,et al.  Fast and accurate measurements of T1 using a multi‐readout single inversion‐recovery sequence , 1992, Magnetic resonance in medicine.

[24]  Y Zhang,et al.  On the accuracy of noninvasive thermometry using molecular diffusion magnetic resonance imaging. , 1992, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[25]  R. Henkelman,et al.  Practical Implementation and Optimization of One‐shot T1 imaging , 1991, Magnetic resonance in medicine.

[26]  G. Glover,et al.  Encoding strategies for three‐direction phase‐contrast MR imaging of flow , 1991, Journal of magnetic resonance imaging : JMRI.

[27]  A. S. Hall,et al.  Observation by MR imaging of in vivo temperature changes induced by radio frequency hyperthermia. , 1990, Journal of computer assisted tomography.

[28]  A. Haase,et al.  Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging , 1990, Magnetic resonance in medicine.

[29]  D Le Bihan,et al.  Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia. , 1989, Radiology.

[30]  A. Crawley,et al.  A comparison of one‐shot and recovery methods in T1 imaging , 1988, Magnetic resonance in medicine.

[31]  A. S. Hall,et al.  Measurement of changes in tissue temperature using MR imaging. , 1986, Journal of computer assisted tomography.

[32]  D. Drost,et al.  Optimization of signal‐to‐noise ratio in calculated T1 images derived from two spin‐echo images , 1986, Magnetic resonance in medicine.

[33]  L. Hall,et al.  Mapping of pH and temperature distribution using chemical-shift-resolved tomography , 1985 .

[34]  T. Cetas,et al.  Will thermometric tomography become practical for hyperthermia treatment monitoring? , 1984, Cancer research.

[35]  D L Parker,et al.  Temperature distribution measurements in two-dimensional NMR imaging. , 1983, Medical physics.

[36]  A. Maudsley,et al.  RAPID MEASUREMENT OF MAGNETIC FIELD DISTRIBUTIONS USING NUCLEAR MAGNETIC RESONANCE. , 1979 .

[37]  B. Bleaney Nuclear magnetic resonance shifts in solution due to lanthanide ions , 1972 .

[38]  D. Look,et al.  Time Saving in Measurement of NMR and EPR Relaxation Times , 1970 .

[39]  J. Hindman,et al.  Proton Resonance Shift of Water in the Gas and Liquid States , 1966 .

[40]  P Wust,et al.  Three‐dimensional monitoring of small temperature changes for therapeutic hyperthermia using MR , 1998, Journal of magnetic resonance imaging : JMRI.

[41]  J. MacFall,et al.  Temperature dependence of canine brain tissue diffusion coefficient measured in vivo with magnetic resonance echo-planar imaging. , 1995, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[42]  F. Jolesz,et al.  Tissue temperature monitoring for thermal interventional therapy: Comparison of T1‐weighted MR sequences , 1994, Journal of magnetic resonance imaging : JMRI.

[43]  L R Schad,et al.  Fast and precise T1 imaging using a TOMROP sequence. , 1990, Magnetic resonance imaging.

[44]  Dennis L. Parker,et al.  Applications of NMR Imaging in Hyperthermia: An Evaluation of the Potential for Localized Tissue Heating and Noninvasive Temperature Monitoring , 1984, IEEE Transactions on Biomedical Engineering.

[45]  C. Lewa,et al.  Temperature relationships of proton spin-lattice relaxation time T1 in biological tissues. , 1980, Bulletin du cancer.

[46]  R. R. Ernst,et al.  Application of Fourier Transform Spectroscopy to Magnetic Resonance , 1966 .

[47]  J. E. Tanner,et al.  Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient , 1965 .