Availability analysis of two-unit warm standby system with inspection time

Abstract This paper deals with two identical units warm standby system when a failure of unit is detected by actual inspection but a system down can be detected at any time without inspection. Where the lifetime distribution of unit is the bivariate exponential distribution and other distributions are arbitrary. The Laplace transform of the point-wise availability of the system and the steady state availability of the system are derived by using the supplementary variable method. Further, we discuss the optimum inspection period maximizing the steady state availability. A numerical example is presented.