Neutronics assessment of different quench tank location options in IFMIF-DONES

Abstract The quench tank (QT) location in the test cell is an open issue for IFMIF-DONES (International Fusion Material Irradiation Facility- DEMO Oriented NEutron Source) design. Neutronics assessments have been carried out on two QT location options. A parametric study of the neutron streaming in the lithium chute shows a quasi-linear dependence of the neutron flux on the void thickness. For both options, activation calculations at key locations of the QT system indicate that the contact dose rate is higher than the hands-on dose limit over the whole maintenance period. In addition, the shutdown dose rates in the lithium facility room after 1-day shutdown exceed the hands-on dose limit in different levels. Therefore, remote handling is required for the maintenances of the QT in both considered locations.