A versatile mechanical ventilator (DIGIT) with high flow stability and a programmable inspiratory phase flow pattern
暂无分享,去创建一个
F. Grianti | F. Montecchia | L. Di Gari | M. Baldassarri | F. Montecchia | F. Grianti | M. Baldassarri | L. Di Gari
[1] R. Chatburn,et al. Mechanical ventilators optimized for pediatric use decrease work of breathing and oxygen consumption during pressure‐support ventilation , 1994, Critical care medicine.
[2] Arthur T. Johnson,et al. Relation Between Limiting Exhalation Flow Rate and Lung Volume , 1987, IEEE Transactions on Biomedical Engineering.
[3] A. Johnson,et al. A new ventilator converter with the Siemens Servo Ventilator ‐ evaluation in a lung model , 1992, Acta anaesthesiologica Scandinavica.
[4] P E Pepe,et al. Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction: the auto-PEEP effect. , 1982, The American review of respiratory disease.
[5] Gerald M. Saidel,et al. Estimation of Mechanical Parameters in Multicompartment Models Applied to Normal and Obstructed Lungs During Tidal Breathing , 1986, IEEE Transactions on Biomedical Engineering.
[6] Susan A. Ward,et al. A Device to Provide Respiratory-Mechanical Unloading , 1986, IEEE Transactions on Biomedical Engineering.
[7] Renzetti Ad,et al. Mechanical behavior of the respiratory system as a function of frequency in health and disease. , 1983 .
[8] D. Cox,et al. Investigation of the spontaneous modes of breathing of different ventilators , 1988, Intensive Care Medicine.
[9] J. Venegas. Equivalent Circuit Analysis of High-Frequency Ventilators Including a New High-Impedance Flow-Interrupting Ventilator , 1986, IEEE Transactions on Biomedical Engineering.
[10] Denis E. O'Donnell,et al. Clinical Respiratory Physiology , 2019, Clinics in Chest Medicine.
[11] Benjamin Bach,et al. Etude de 11 ventilateurs d'anesthésie : banc d'essai , 1992, Annales Françaises d'Anesthésie et de Réanimation.
[12] W. Kox,et al. Effect of weaning on oxygen consumption and cardiovascular function A comparison of continuous flow and demand valve systems , 1994, Anaesthesia.
[13] William Woolf Mushin,et al. Automatic ventilation of the lungs , 1969 .
[14] D. Hill,et al. THE ACTION OF ADIABATIC EFFECTS ON THE COMPLIANCE OF AN ARTIFICIAL THORAX. , 1965, British journal of anaesthesia.
[15] A. Baker,et al. Towards a Better Classification of Lung Ventilators , 1974, Anaesthesia and intensive care.
[16] B.A. Simon,et al. Design and calibration of a high-frequency oscillatory ventilator , 1991, IEEE Transactions on Biomedical Engineering.
[17] K. Lutchen,et al. Human respiratory input impedance from 4 to 200 Hz: physiological and modeling considerations. , 1988, Journal of applied physiology.
[18] A. Johnson,et al. Comparison of anaesthesia ventilators using a lung model , 1990, Acta anaesthesiologica Scandinavica.
[19] A S Slutsky,et al. Factors inducing periodic breathing in humans: a general model. , 1982, Journal of applied physiology: respiratory, environmental and exercise physiology.
[20] S. P. McPherson,et al. Respiratory therapy equipment , 1977 .
[21] R. A. Epstein,et al. A new ventilator for physiologic studies during high-frequency ventilation. , 1982, Respiration Physiology.
[22] H J Bender,et al. [The performance of respirator alarms during simulated critical events in CMV/IPPV artificial respiration]. , 1993, Der Anaesthesist.
[23] G. Heldt,et al. Response time and reliability of three neonatal patient-triggered ventilators. , 1993, The American review of respiratory disease.