Refrigerant-based measurement method of heat pump seasonal performances

There is no reliable measurement method of air-to-air heat pump seasonal performances. In this paper, we tested a method based on intrusive measurements on the refrigerant side. The method proposed uses two Coriolis mass flow meters for the measurement of the refrigerant flow rate and of the vapor quality at the indoor heat exchanger outlet. The method is validated by testing an air-to-water heat pump in laboratory conditions and by using the water enthalpy method as a reference. Results confirm that the refrigerant density measurement with a Coriolis flow meter can help to predict the refrigerant vapor quality with satisfactory accuracy if the quality is not too high. The method is also reliable in dynamic conditions (including for defrosting periods). It will then be used as a reference to check the accuracy of different in situ measurement methods for air-to-air heat pumps.

[1]  Michele Zehnder Efficient air-water heat pumps for high temperature lift residential heating, including oil migration aspects , 2004 .

[2]  C. J. Baroczy,et al.  CORRELATION OF LIQUID FRACTION IN TWO-PHASE FLOW WITH APPLICATION TO LIQUID METALS , 1963 .

[3]  S. L. Smith Void Fractions in Two-Phase Flow: A Correlation Based upon an Equal Velocity Head Model , 1969 .

[4]  C. P. Gupta,et al.  A void fraction model for annular two-phase flow , 1985 .

[5]  Manuel R. Conde,et al.  Estimation of thermophysical properties of lubricating oils and their solutions with refrigerants: An appraisal of existing methods , 1996 .

[6]  Clement C. Tang,et al.  Comparison of Void Fraction Correlations for Different Flow Patterns in Upward Vertical Two-Phase Flow , 2011 .

[7]  S. Zivi Estimation of Steady-State Steam Void-Fraction by Means of the Principle of Minimum Entropy Production , 1964 .

[8]  Per Fahlén Methods for commissioning and performance checking of heat pumps and refrigeration equipment , 2004 .

[9]  Guoliang Ding,et al.  Experimental validation of void fraction models for R410A air conditioners , 2009 .

[10]  C. K. Rice The effect of void fraction correlation and heat flux assumption on refrigerant charge inventory predictions , 1987 .

[11]  H. S. Isbin,et al.  Void fractions in two‐phase flow , 1959 .

[12]  A void fraction model for annular flow in horizontal tubes , 2003 .

[13]  A. Ghajar,et al.  Comparison of void fraction correlations for different flow patterns in horizontal and upward inclined pipes , 2007 .

[14]  G. Fasman,et al.  Physical and chemical data , 1976 .

[15]  E. Ferguson In Situ Measurements , 1982 .