On improving the speed and reliability of T2‐relaxation‐under‐spin‐tagging (TRUST) MRI

A T2‐relaxation‐under‐spin‐tagging technique was recently developed to estimate cerebral blood oxygenation, providing potentials for noninvasive assessment of the brain's oxygen consumption. A limitation of the current sequence is the need for long repetition time, as shorter repetition time causes an over‐estimation in blood R2. This study proposes a postsaturation T2‐relaxation‐under‐spin‐tagging by placing a nonselective 90° pulse after the signal acquisition to reset magnetization in the whole brain. This scheme was found to eliminate estimation bias at a slight cost of precision. To improve the precision, echo time of the sequence was optimized and it was found that a modest echo time shortening of 3.4 ms can reduce the estimation error by 49%. We recommend the use of postsaturation T2‐relaxation‐under‐spin‐tagging sequence with a repetition time of 3000 ms and a echo time of 3.6 ms, which allows the determination of global venous oxygenation with scan duration of 1 min 12 s and an estimation precision of ±1% (in units of oxygen saturation percentage). Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.

[1]  E. Haacke,et al.  Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime , 1994, Magnetic resonance in medicine.

[2]  J R Reichenbach,et al.  In vivo measurement of blood oxygen saturation using magnetic resonance imaging: A direct validation of the blood oxygen level‐dependent concept in functional brain imaging , 1997, Human brain mapping.

[3]  Xavier Golay,et al.  Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla , 2004, Magnetic resonance in medicine.

[4]  Hanzhang Lu,et al.  Quantitative evaluation of oxygenation in venous vessels using T2‐Relaxation‐Under‐Spin‐Tagging MRI , 2008, Magnetic resonance in medicine.

[5]  Denise C. Park,et al.  Alterations in cerebral metabolic rate and blood supply across the adult lifespan. , 2011, Cerebral cortex.

[6]  X Golay,et al.  Comparison of the dependence of blood R2 and R  2* on oxygen saturation at 1.5 and 4.7 Tesla , 2003, Magnetic resonance in medicine.

[7]  Albert Macovski,et al.  Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T , 1991 .

[8]  D. Yablonskiy,et al.  Quantitative BOLD: Mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: Default state , 2007, Magnetic resonance in medicine.

[9]  Felix W Wehrli,et al.  MRI Estimation of Global Brain Oxygen Consumption Rate , 2010, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[10]  L. Ciobanu,et al.  Functional imaging with FENSI: Flow‐enhanced signal intensity , 2007, Magnetic resonance in medicine.

[11]  T. L. Davis,et al.  Calibrated functional MRI: mapping the dynamics of oxidative metabolism. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[12]  Hanzhang Lu,et al.  Noninvasive quantification of whole‐brain cerebral metabolic rate of oxygen (CMRO2) by MRI , 2009, Magnetic resonance in medicine.

[13]  M. Schnall,et al.  Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla , 2002, Magnetic resonance in medicine.

[14]  Y Yonekura,et al.  Evaluation of brain metabolism in steno-occlusive carotid artery disease by proton MR spectroscopy: a correlative study with oxygen metabolism by PET. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  S. Kondo,et al.  Clinical significance of reduced cerebral metabolism in multiple sclerosis: A combined PET and MRI study , 1998, Annals of nuclear medicine.

[16]  M. van Buchem,et al.  Can arterial spin labeling detect white matter perfusion signal? , 2009, Magnetic resonance in medicine.

[17]  Xavier Golay,et al.  Measurement of tissue oxygen extraction ratios from venous blood T2: Increased precision and validation of principle , 2001, Magnetic resonance in medicine.

[18]  Risto A. Kauppinen,et al.  Quantitative assessment of blood flow, blood volume and blood oxygenation effects in functional magnetic resonance imaging , 1998, Nature Medicine.

[19]  Peiying Liu,et al.  Calibration and validation of TRUST MRI for the estimation of cerebral blood oxygenation , 2012, Magnetic resonance in medicine.

[20]  S. Kety,et al.  THE EFFECTS OF ALTERED ARTERIAL TENSIONS OF CARBON DIOXIDE AND OXYGEN ON CEREBRAL BLOOD FLOW AND CEREBRAL OXYGEN CONSUMPTION OF NORMAL YOUNG MEN. , 1948, The Journal of clinical investigation.

[21]  J. Detre,et al.  Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling. , 2000, Stroke.

[22]  Yulin Ge,et al.  Baseline blood oxygenation modulates response amplitude: Physiologic basis for intersubject variations in functional MRI signals , 2008, Magnetic resonance in medicine.

[23]  Peter C M van Zijl,et al.  Oxygenation and hematocrit dependence of transverse relaxation rates of blood at 3T , 2007, Magnetic resonance in medicine.

[24]  Felix W Wehrli,et al.  MR susceptometry for measuring global brain oxygen extraction , 2006, Magnetic resonance in medicine.

[25]  Jeroen van der Grond,et al.  Measurements of cerebral perfusion and arterial hemodynamics during visual stimulation using TURBO‐TILT , 2003, Magnetic resonance in medicine.

[26]  R. Buxton,et al.  Dynamics of blood flow and oxygenation changes during brain activation: The balloon model , 1998, Magnetic resonance in medicine.

[27]  Weili Lin,et al.  Impact of intravascular signal on quantitative measures of cerebral oxygen extraction and blood volume under normo‐ and hypercapnic conditions using an asymmetric spin echo approach , 2003, Magnetic resonance in medicine.

[28]  Peter C M van Zijl,et al.  Determination of whole‐brain oxygen extraction fractions by fast measurement of blood T2 in the jugular vein , 2011, Magnetic resonance in medicine.

[29]  Risto A. Kauppinen,et al.  Determination of Oxygen Extraction Ratios by Magnetic Resonance Imaging , 1999, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[30]  J. Detre,et al.  Optical measurement of cerebral hemodynamics and oxygen metabolism in neonates with congenital heart defects. , 2010, Journal of biomedical optics.

[31]  D G Gadian,et al.  Implementation of quantitative FAIR perfusion imaging with a short repetition time in time‐course studies , 1999, Magnetic resonance in medicine.

[32]  G. Crelier,et al.  Linear coupling between cerebral blood flow and oxygen consumption in activated human cortex. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[33]  H. An,et al.  Quantitative measurements of cerebral metabolic rate of oxygen utilization using MRI: a volunteer study , 2001, NMR in biomedicine.

[34]  Feng Xu,et al.  The Influence of Carbon Dioxide on Brain Activity and Metabolism in Conscious Humans , 2011, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.