Oil flooded compression cycle enhancement for two-stage heat pump in cold climate region: System design and theoretical analysis

Abstract In order to improve the performance of air source heat pump in cold climate region, a combined oil flooded compression with regenerator and vapor injection cycle system is suggested in this paper, which integrates oil flooded compression with regenerator into a conventional vapor injection cycle. A mathematical model is developed and parametric studies on this cycle are conducted to evaluate the benefits of the novel system. The performances of the novel system using R410A and R32 are compared with those of vapor injection cycle system. The improvement of coefficient of performance (COP) can reach up to nearly 9% based on the same isentropic efficiency, while 17.2% based on assumption that there is a 10% rise in isentropic efficiency brought by oil flooded compression cycle. The heating capacity is reduced by 8–18% based on the same volumetric efficiency, while could be less than 10% in a practical system. The discharge temperature is largely decreased and can be below 100 °C at −40 °C Te and 50 °C Tc condition for R32. The theoretical results demonstrate this novel heat pump has a high potential for improving the performance of air source heat pump in cold climate region.

[1]  Michele De Carli,et al.  An analysis of solar assisted ground source heat pumps in cold climates , 2015 .

[3]  Reinhard Radermacher,et al.  Performance comparison of R410A and R32 in vapor injection cycles , 2013 .

[4]  W. T. Horton,et al.  Experimental analysis of oil flooded R410A scroll compressor , 2014 .

[5]  James E. Braun,et al.  Performance of Vapor Compression Systems with Compressor Oil Flooding and Regeneration , 2011 .

[6]  Reinhard Radermacher,et al.  Testing, simulation and soft-optimization of R410A low-GWP alternatives in heat pump system , 2015 .

[7]  Milad Ashouri,et al.  Thermo-economic and thermodynamic analysis and optimization of a two-stage irreversible heat pump , 2015 .

[8]  W. T. Horton,et al.  Experimental testing of an oil-flooded hermetic scroll compressor , 2013 .

[9]  Baojun Luo,et al.  Effects of component performance on overall performance of R410A air conditioner with oil flooding and regeneration , 2016 .

[10]  E. Groll,et al.  Two-stage air-source heat pump for residential heating and cooling applications in northern U.S. climates , 2008 .

[11]  Eckhard A. Groll,et al.  Air Source Heat Pump for Northern Climates Part I: Simulation of Different Heat Pump Cycles , 2006 .

[12]  Ibrahim Dincer,et al.  Comparative performance evaluation of cascaded air-source hydronic heat pumps , 2015 .

[13]  Sugirdhalakshmi Ramaraj Vapor compression cycle enhancements for cold climate heat pumps , 2012 .

[14]  Vincent Lemort,et al.  Liquid-flooded compression and expansion in scroll machines - Part I: Model development , 2012 .

[15]  Amenallah Guizani,et al.  Performance of the coupling of the flat plate collector and a heat pump system associated with a vertical heat exchanger for heating of the two types of greenhouses system , 2015 .

[16]  Vincent Lemort,et al.  Liquid flooded compression and expansion in scroll machines – Part II: Experimental testing and model validation , 2012 .