3D aortic morphology and stiffness in MRI using semi-automated cylindrical active surface provides optimized description of the vascular effects of aging and hypertension

BACKGROUND Clinically, aortic geometry assessment is mainly based on the measurement of maximal diameters at different anatomic locations, which are subsequently used to indicate prophylactic aortic surgery. However, 3D evaluation of aortic morphology could provide volumetric quantification, which integrates both aortic dilatation and elongation and might thus be more sensitive to early geometric changes than diameters. Precise aortic morphology is also required for the calculation of pulse wave velocity (PWVMRI), an established marker of aortic stiffness. Accordingly, we proposed a 3D semi-automated analysis of thoracic aorta MRI data optimizing morphological and subsequent stiffness assessment. METHODS We studied 74 individuals (40 males, 50 ± 12years): 21 healthy volunteers and 53 patients with hypertension in whom aortic 3D MRI angiography and 2D + t phase-contrast and cine imaging were performed. A semi-automated method was proposed for volumetric aortic segmentation and was evaluated by studying resulting measurements (length, diameters, volumes and PWVMRI) in terms of: 1) reproducibility, 2) correlations with well-established 2D aortic length and diameters, 3) associations with age, carotid-femoral PWV (cf-PWV) and presence of hypertension. RESULTS The measurements obtained with the proposed method were reproducible (coefficients of variation ≤ 5.1%) and were highly correlated with 2D measurements (arch length: r = 0.80, Bland-Altman mean bias [limits]: 2.7 mm [-25; 30]; PWVMRI: r = 0.95, 0.22 m/s [-1.9; 2.4]). Higher or similar correlations with age were found for the proposed 3D method compared to the 2D approach (arch length: r = 0.47 (2D), r = 0.60 (3D); PWVMRI: r = 0.63 (2D), r = 0.64 (3D)). Moreover, a significant association was found between PWVMRI and cf-PWV (r = 0.49, p < 0.001). All aortic measurements increased with hypertension (p < 0.05) and with age: arch length (+9mm/decade); diameters: ascending (+1.2mm/decade) and descending aorta (+1.0mm/decade); volumes: ascending (+2.6mL/decade) and descending aorta (+4.0mL/decade); PWVMRI (+1.7  m s-1/decade). CONCLUSIONS A semi-automated method based on cylindrical active surfaces was proposed for the 3D segmentation of the aorta using a single MRI dataset, providing aortic diameters at anatomical landmarks, aortic volumes and the aortic centerline length used for PWV estimation. Such measurements were reproducible and comparable to expert measurements, which required time-consuming centerline delineation. Furthermore, expected relationships with age and hypertension were found indicating the consistency of our measurements.

[1]  Denis Friboulet,et al.  B-Spline Explicit Active Surfaces: An Efficient Framework for Real-Time 3-D Region-Based Segmentation , 2012, IEEE Transactions on Image Processing.

[2]  A. Redheuil Cardiovascular aging: Insights from local and regional measures of aortic stiffness using magnetic resonance imaging , 2014 .

[3]  D. Bluemke,et al.  Determinants and normal values of ascending aortic diameter by age, gender, and race/ethnicity in the Multi‐Ethnic Study of Atherosclerosis (MESA) , 2014, Journal of magnetic resonance imaging : JMRI.

[4]  V. Gudnason,et al.  Longitudinal and Circumferential Strain of the Proximal Aorta , 2014, Journal of the American Heart Association.

[5]  D. Bluemke,et al.  Age-related changes in aortic arch geometry: relationship with proximal aortic function and left ventricular mass and remodeling. , 2011, Journal of the American College of Cardiology.

[6]  D. Bluemke,et al.  Association of Aortic Stiffness With Left Ventricular Remodeling and Reduced Left Ventricular Function Measured by Magnetic Resonance Imaging: The Multi-Ethnic Study of Atherosclerosis , 2016, Circulation. Cardiovascular imaging.

[7]  Frédérique Frouin,et al.  Automated estimation of aortic strain from steady‐state free‐precession and phase contrast MR images , 2011, Magnetic resonance in medicine.

[8]  Frédérique Frouin,et al.  Automated segmentation of the aorta from phase contrast MR images: Validation against expert tracing in healthy volunteers and in patients with a dilated aorta , 2010, Journal of magnetic resonance imaging : JMRI.

[9]  A. Redheuil,et al.  Geometry is a major determinant of flow reversal in proximal aorta. , 2014, American journal of physiology. Heart and circulatory physiology.

[10]  Thomas M Grist,et al.  Review of MRI-based measurements of pulse wave velocity: a biomarker of arterial stiffness. , 2014, Cardiovascular diagnosis and therapy.

[11]  A. Barker,et al.  Quantification of Hemodynamic Wall Shear Stress in Patients with Bicuspid Aortic Valve Using Phase-Contrast MRI , 2010, Annals of Biomedical Engineering.

[12]  A. Redheuil,et al.  How to estimate aortic characteristic impedance from magnetic resonance and applanation tonometry data? , 2015, Journal of hypertension.

[13]  Alban Redheuil,et al.  Measurement of aortic arch pulse wave velocity in cardiovascular MR: Comparison of transit time estimators and description of a new approach , 2011, Journal of magnetic resonance imaging : JMRI.

[14]  Allen R. Tannenbaum,et al.  Localizing Region-Based Active Contours , 2008, IEEE Transactions on Image Processing.

[15]  D. Bluemke,et al.  Normal values for cardiovascular magnetic resonance in adults and children , 2015, Journal of Cardiovascular Magnetic Resonance.

[16]  É. Mousseaux,et al.  Consistency of aortic distensibility and pulse wave velocity estimates with respect to the Bramwell-Hill theoretical model: a cardiovascular magnetic resonance study , 2011, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[17]  R. V. Van Uitert,et al.  Subvoxel precise skeletons of volumetric data based on fast marching methods. , 2007, Medical physics.

[18]  H. Marquering,et al.  Volumetric arterial wall shear stress calculation based on cine phase contrast MRI , 2015, Journal of magnetic resonance imaging : JMRI.

[19]  Petter Dyverfeldt,et al.  Extended 3D approach for quantification of abnormal ascending aortic flow. , 2015, Magnetic resonance imaging.

[20]  J. Staessen,et al.  Clinical applications of arterial stiffness; definitions and reference values. , 2002, American journal of hypertension.

[21]  J. Lima,et al.  Estimation of aortic pulse wave transit time in cardiovascular magnetic resonance using complex wavelet cross-spectrum analysis , 2015, Journal of Cardiovascular Magnetic Resonance.

[22]  D. Bluemke,et al.  Proximal aortic distensibility is an independent predictor of all-cause mortality and incident CV events: the MESA study. , 2014, Journal of the American College of Cardiology.

[23]  Mark Butlin,et al.  The relationship of age with regional aortic stiffness and diameter. , 2010, JACC. Cardiovascular imaging.

[24]  J. Elefteriades,et al.  Thoracic aortic aneurysm clinically pertinent controversies and uncertainties. , 2010, Journal of the American College of Cardiology.

[25]  C. Vlachopoulos,et al.  Prediction of Cardiovascular Events and All-Cause Mortality With Arterial Stiffness , 2011 .

[26]  Denis Friboulet,et al.  Real-time 3D interactive segmentation of echocardiographic data through user-based deformation of B-spline explicit active surfaces , 2014, Comput. Medical Imaging Graph..

[27]  T. Sundt,et al.  Aortic surgery for ascending aortic aneurysms under 5.0 cm in diameter in the presence of bicuspid aortic valve. , 2013, JACC Cardiovascular Imaging.

[28]  Aly A. Farag,et al.  MultiStencils Fast Marching Methods: A Highly Accurate Solution to the Eikonal Equation on Cartesian Domains , 2007, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[29]  J. Francis,et al.  Observational study of regional aortic size referenced to body size: production of a cardiovascular magnetic resonance nomogram , 2014, Journal of Cardiovascular Magnetic Resonance.

[30]  René M. Botnar,et al.  Aortic length measurements for pulse wave velocity calculation: manual 2D vs automated 3D centreline extraction , 2017, Journal of Cardiovascular Magnetic Resonance.