Flow compensation for the fast spin echo triple-echo Dixon sequence.

The fast spin echo (FSE) triple-echo Dixon (FTED) sequence uses bipolar triple-echo readout during each echo-spacing period of FSE to collect all the images necessary for Dixon water and fat separation in a single scan. In comparison to other FSE implementations of the Dixon technique, the triple echo readout used in FTED incurs minimal deadtime in the pulse sequence design and thus greatly enhances the overall scan efficiency. A potential drawback of FTED is that the time dependence of the gradient moment along the frequency encode direction becomes more complicated than in FSE and flow compensation based on the gradient moment (GM) nulling is difficult to achieve. In this work, the first order GM along the frequency encode direction of FTED was examined and two different methods to minimize the GM were proposed. The first method nulls the GM at all the locations of the refocusing radiofrequency pulses so that the Carr-Purcell Meiboom-Gill condition is always maintained. The second method minimizes the GM of the spin echo component of the FSE signal at the echo locations. The efficacy of both methods in reducing the first order GM and flow-related artefacts was demonstrated both in phantom and in images in vivo.

[1]  Jean A. Tkach,et al.  Separation of fat and water in fast spin‐echo MR imaging with the three‐point dixon technique , 1995, Journal of magnetic resonance imaging : JMRI.

[2]  G M Bydder,et al.  MR Imaging: Clinical Use of the Inversion Recovery Sequence , 1985, Journal of computer assisted tomography.

[3]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[4]  Jingfei Ma,et al.  A fast spin echo two-point Dixon technique and its combination with sensitivity encoding for efficient T2-weighted imaging. , 2005, Magnetic resonance imaging.

[5]  G. Gold,et al.  Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): Application with fast spin‐echo imaging , 2005, Magnetic resonance in medicine.

[6]  Jingfei Ma,et al.  Fast spin‐echo triple‐echo dixon (fTED) technique for efficient T2‐weighted water and fat imaging , 2007, Magnetic resonance in medicine.

[7]  J. Duerk,et al.  Motion artifact suppression technique (MAST) for MR imaging. , 1987, Journal of computer assisted tomography.

[8]  Jingfei Ma,et al.  Method for efficient fast spin echo Dixon imaging , 2002, Magnetic resonance in medicine.

[9]  G. Glover Multipoint dixon technique for water and fat proton and susceptibility imaging , 1991, Journal of magnetic resonance imaging : JMRI.

[10]  R. S. Hinks,et al.  Gradient moment nulling in fast spin echo , 1994, Magnetic resonance in medicine.

[11]  Jingfei Ma,et al.  Breath‐hold water and fat imaging using a dual‐echo two‐point dixon technique with an efficient and robust phase‐correction algorithm , 2004, Magnetic resonance in medicine.

[12]  Jingfei Ma,et al.  Fast spin‐echo triple‐echo Dixon: Initial clinical experience with a novel pulse sequence for fat‐suppressed T2‐weighted abdominal MR imaging , 2009, Journal of magnetic resonance imaging : JMRI.

[13]  E M Haacke,et al.  Improving MR image quality in the presence of motion by using rephasing gradients. , 1987, AJR. American journal of roentgenology.

[14]  W. T. Dixon Simple proton spectroscopic imaging. , 1984, Radiology.

[15]  F A Jolesz,et al.  Contrast manipulation and artifact assessment of 2D and 3D RARE sequences. , 1990, Magnetic resonance imaging.

[16]  E. Jackson,et al.  Improving Fat-Suppressed T2-Weighted Imaging of the Head and Neck with 2 Fast Spin-Echo Dixon Techniques: Initial Experiences , 2008, American Journal of Neuroradiology.

[17]  Jingfei Ma Dixon techniques for water and fat imaging , 2008, Journal of magnetic resonance imaging : JMRI.

[18]  A. Haase,et al.  Chemical shift selective MR imaging using a whole-body magnet. , 1985, Radiology.

[19]  F A Jolesz,et al.  Phase-encode order and its effect on contrast and artifact in single-shot RARE sequences. , 1991, Medical physics.

[20]  R. Henkelman,et al.  Why fat is bright in rare and fast spin‐echo imaging , 1992, Journal of magnetic resonance imaging : JMRI.

[21]  P Schmalbrock,et al.  Multisection fat-water imaging with chemical shift selective presaturation. , 1987, Radiology.