Optimal risk-aware power procurement for data centers in day-ahead and real-time electricity markets

With the growing trend in the amount of power consumed by data centers, finding ways to cut their electricity bills has become an important and challenging problem. In this paper, our focus is on the cost reduction that data centers may achieve by exploiting the diversity in the price of electricity in day-ahead and real-time electricity markets. Based on a stochastic optimization framework, we propose to jointly select a data center's service rate and its power demand bids to the day-ahead and real-time electricity markets. In our analysis, we take into account service-level-agreements, risk management constraints, and statistical characteristics of workload and electricity prices. Using empirical electricity price and Internet workload data and through computer simulations, we show that by directly participating in the day-ahead and real-time electricity markets, data centers can significantly reduce their energy expenditure.

[1]  Adam Wierman,et al.  Energy procurement strategies in the presence of intermittent sources , 2014, SIGMETRICS '14.

[2]  D.W. Bunn,et al.  Forecasting loads and prices in competitive power markets , 2000, Proceedings of the IEEE.

[3]  Stephen P. Boyd,et al.  Convex Optimization , 2004, Algorithms and Theory of Computation Handbook.

[4]  Wolf-Dietrich Weber,et al.  Power provisioning for a warehouse-sized computer , 2007, ISCA '07.

[5]  Hamed Mohsenian Rad,et al.  Profit maximization and power management of green data centers supporting multiple slas , 2013, 2013 International Conference on Computing, Networking and Communications (ICNC).

[6]  Ricardo Bianchini,et al.  Dynamic cluster reconfiguration for power and performance , 2003 .

[7]  Adam Wierman,et al.  Pricing data center demand response , 2014, SIGMETRICS '14.

[8]  J. H. Teng,et al.  The optimal portfolio of the day-ahead market and real-time market for the load serving entities , 2010, 2010 8th IEEE International Conference on Industrial Informatics.

[9]  Mohammad Shahidehpour,et al.  Market operations in electric power systems , 2002 .

[10]  Tajana Simunic,et al.  Distributed battery control for peak power shaving in datacenters , 2013, 2013 International Green Computing Conference Proceedings.

[11]  Hamed Mohsenian Rad,et al.  Optimal Residential Load Control With Price Prediction in Real-Time Electricity Pricing Environments , 2010, IEEE Transactions on Smart Grid.

[12]  Adam Wierman,et al.  Data center demand response: avoiding the coincident peak via workload shifting and local generation , 2013, SIGMETRICS '13.

[13]  Mohammad Shahidehpour,et al.  SecurityConstrained Unit Commitment , 2002 .

[14]  Amir-Hamed Mohsenian-Rad,et al.  Energy-Information Transmission Tradeoff in Green Cloud Computing , 2010 .

[15]  Hamed Mohsenian Rad,et al.  Data centers to offer ancillary services , 2012, 2012 IEEE Third International Conference on Smart Grid Communications (SmartGridComm).

[16]  Xue Liu,et al.  Hedging Against Uncertainty: A Tale of Internet Data Center Operations Under Smart Grid Environment , 2011, IEEE Transactions on Smart Grid.

[17]  Myung J. Lee,et al.  Green IT : technologies and applications , 2011 .

[18]  BalakrishnanHari,et al.  Cutting the electric bill for internet-scale systems , 2009, SIGCOMM '09.

[19]  Michel Savoie,et al.  Powering a Data Center Network via Renewable Energy: A Green Testbed , 2013, IEEE Internet Computing.

[20]  Xiao-Ping Zhang Restructured electric power systems : analysis of electricity markets with equilibrium models , 2010 .

[21]  Mi Zhou,et al.  Surge immunity test of personal computer at power lines , 2011, 2011 7th Asia-Pacific International Conference on Lightning.

[22]  Tao Jiang,et al.  Risk-constrained operation for internet data centers under smart grid environment , 2013, 2013 International Conference on Wireless Communications and Signal Processing.

[23]  B. Wollenberg,et al.  Risk assessment of generators bidding in day-ahead market , 2005, IEEE Transactions on Power Systems.

[24]  Peter Marwedel,et al.  Reducing energy consumption by dynamic copying of instructions onto onchip memory , 2002, 15th International Symposium on System Synthesis, 2002..

[25]  A. Leon-Garcia,et al.  Probability, statistics, and random processes for electrical engineering , 2008 .

[26]  Hamed Mohsenian Rad,et al.  Energy and Performance Management of Green Data Centers: A Profit Maximization Approach , 2013, IEEE Transactions on Smart Grid.

[27]  Hamed Mohsenian Rad,et al.  Optimal integration of renewable energy resources in data centers with behind-the-meter renewable generator , 2012, 2012 IEEE International Conference on Communications (ICC).

[28]  Bruce M. Maggs,et al.  Cutting the electric bill for internet-scale systems , 2009, SIGCOMM '09.

[29]  S. Oren,et al.  Electricity derivatives and risk management , 2005 .

[30]  Nagarajan Kandasamy,et al.  Power and performance management of virtualized computing environments via lookahead control , 2008, 2008 International Conference on Autonomic Computing.

[31]  Amir-Hamed Mohsenian-Rad,et al.  Coordination of Cloud Computing and Smart Power Grids , 2010, 2010 First IEEE International Conference on Smart Grid Communications.

[32]  Lachlan L. H. Andrew,et al.  Geographical load balancing with renewables , 2011, PERV.

[33]  Ricardo Bianchini,et al.  Leveraging renewable energy in data centers: present and future , 2012, HPDC '12.