Total knee arthroplasty in young active patients using a highly congruent fully mobile prosthesis.

A consecutive cohort of 63 young patients (80 knees; mean age, 50.7 years) received a Rotaglide mobile knee (Corin Ltd, Cirencester, UK) prosthesis as a primary procedure by a single UK surgeon. Mean follow-up period is 7.3 years (range, 3-12 years). Patients were assessed using the International Knee Society Score and the Oxford Knee Score. Radiolucency was assessed using the Knee Society roentgenographic system. The patients demonstrated an excellent knee and function International Knee Society Score of 98 and 93.6, respectively, with an Oxford Knee Score of 15.5. One knee was revised for traumatic dislocation of the mobile bearing. There were no revisions for aseptic loosening or deep infection. This study demonstrates encouraging midterm results for this device in a young patient cohort.

[1]  G. Makris,et al.  Evaluation of Contact Stress in Metal‐Backed Patellar Replacements , 1991, Clinical orthopaedics and related research.

[2]  R. Scott,et al.  Total knee arthroplasty in a group of patients less than 45 years of age. , 1995, The Journal of arthroplasty.

[3]  E. Kaplan,et al.  Nonparametric Estimation from Incomplete Observations , 1958 .

[4]  F. C. Ewald The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. , 1989, Clinical orthopaedics and related research.

[5]  A. Carr,et al.  Questionnaire on the perceptions of patients about total knee replacement. , 1998, The Journal of bone and joint surgery. British volume.

[6]  J. O'Connor,et al.  Polyethylene wear in meniscal knee replacement. A one to nine-year retrieval analysis of the Oxford knee. , 1992, The Journal of bone and joint surgery. British volume.

[7]  J. O'Connor,et al.  Clinical results of the Oxford knee. Surface arthroplasty of the tibiofemoral joint with a meniscal bearing prosthesis. , 1986, Clinical orthopaedics and related research.

[8]  R. E. Jensen,et al.  Analysis of the Failure of 122 Polyethylene Inserts From Uncemented Tibial Knee Components , 1991, Clinical orthopaedics and related research.

[9]  D. Bartel,et al.  The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. , 1986, The Journal of bone and joint surgery. American volume.

[10]  K. C. Chan,et al.  5- to 18-year follow-up study of cemented total knee arthroplasty for patients 55 years old or younger. , 1997, The Journal of arthroplasty.

[11]  J. Rand,et al.  Total knee arthroplasty in young adults who have rheumatoid arthritis. , 1988, The Journal of bone and joint surgery. American volume.

[12]  S. Stern,et al.  Cemented total knee arthroplasty for gonarthrosis in patients 55 years old or younger. , 1990, Clinical orthopaedics and related research.

[13]  J. Goodfellow Knee prostheses--one step forward, two steps back. , 1992, The Journal of bone and joint surgery. British volume.

[14]  G. Scuderi**,et al.  The posterior stabilized total knee prosthesis. Assessment of polyethylene damage and osteolysis after a ten-year-minimum follow-up. , 1995, The Journal of bone and joint surgery. American volume.

[15]  L. Dorr,et al.  Rationale of the Knee Society clinical rating system. , 1989, Clinical orthopaedics and related research.

[16]  C. Ranawat,et al.  Total knee arthroplasty for patients younger than 55 years. , 1989, Clinical orthopaedics and related research.

[17]  Young-Hoo Kim,et al.  Comparison of Fixed-Bearing and Mobile-Bearing Total Knee Arthroplasties , 2001, Clinical orthopaedics and related research.

[18]  Ff Beuchel A metal-backed rotating bearing patella prosthesis to lower contact stress , 1989 .

[19]  J. Insall,et al.  The total condylar knee prosthesis in gonarthrosis. A five to nine-year follow-up of the first one hundred consecutive replacements. , 1983, The Journal of bone and joint surgery. American volume.