Cavity ring down spectroscopy: detection of trace amounts of substance

We describe several applications of cavity ring-down spectroscopy (CRDS) for trace matter detection. NO2 sensor was constructed in our team using this technique and blue-violet lasers (395–440 nm). Its sensitivity is better than single ppb. CRDS at 627 nm was used for detection of NO3. Successful monitoring of N2O in air requires high precision mid-infrared spectroscopy. These sensors might be used for atmospheric purity monitoring as well as for explosives detection. Here, the spectroscopy on sharp vibronic molecular resonances is performed. Therefore the single mode lasers which can be tuned to selected molecular lines are used. Similarly, the spectroscopy at 936 nm was used for sensitive water vapour detection. The opportunity of construction of H2O sensor reaching the sensitivity about 10 ppb is also discussed.

[1]  S. Herndon,et al.  A practical alternative to chemiluminescence-based detection of nitrogen dioxide: cavity attenuated phase shift spectroscopy. , 2008, Environmental science & technology.

[2]  M. Quack Fundamentals of Molecular Spectroscopy. Von W. S. Struve. Wiley, Chichester 1989. 379 S., geb. £ 31.95. – ISBN 0-471-85424-7 , 1990 .

[3]  Kenneth W. Busch,et al.  Cavity-ringdown spectroscopy : an ultratrace-absorption measurement technique , 1999 .

[4]  A. O’Keefe,et al.  Cavity ring‐down optical spectrometer for absorption measurements using pulsed laser sources , 1988 .

[5]  R. Cohen,et al.  Preparing to Measure the Effects of the NOx SIP Call— Methods for Ambient Air Monitoring of NO, NO2, NOy, and Individual NOz Species , 2002, Journal of the Air & Waste Management Association.

[6]  S. Herndon,et al.  Detection of nitrogen dioxide by cavity attenuated phase shift spectroscopy. , 2005, Analytical chemistry.

[7]  V. L. Kasyutich,et al.  Off-axis continuous-wave cavity-enhanced absorption spectroscopy of narrow-band and broadband absorbers using red diode lasers , 2002 .

[8]  Gang Li,et al.  The HITRAN 2008 molecular spectroscopic database , 2005 .

[9]  Z. Bielecki,et al.  Signal processing system in cavity enhanced spectroscopy , 2008 .

[10]  Rudy Peeters,et al.  Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy , 1998 .

[11]  A. Ravishankara,et al.  Measurement of atmospheric NO2 by pulsed cavity ring-down spectroscopy , 2006 .

[12]  Joseph T. Hodges,et al.  High-resolution cavity ring-down spectroscopy measurements of blended H2O transitions , 2007 .

[13]  J. Hodges,et al.  Comparison of semiclassical line-shape models to rovibrational H2O spectra measured by frequency-stabilized cavity ring-down spectroscopy , 2006 .

[14]  C F Kaminski,et al.  Cavity enhanced absorption spectroscopy of multiple trace gas species using a supercontinuum radiation source. , 2008, Optics express.

[15]  R. Yokelson,et al.  Temperature Dependence of the NO 3 Absorption Spectrum , 2001 .

[16]  C. N. Banwell,et al.  Fundamentals of molecular spectroscopy , 1966 .

[17]  W. Marinelli,et al.  Absorption cross sections and line shape for the NO3(0–0) band , 1981 .

[18]  A. Ravishankara,et al.  Temperature Dependence of the NO3 Absorption Spectrum , 1994 .

[19]  Jonathan Tennyson,et al.  Comparison between theoretical calculations and high-resolution measurements of pressure broadening for near-infrared water spectra , 2008 .

[20]  J. Seinfeld,et al.  Atmospheric Chemistry and Physics: From Air Pollution to Climate Change , 1997 .

[21]  C. Pfrang,et al.  Cavity-enhanced absorption: detection of nitrogen dioxide and iodine monoxide using a violet laser diode , 2003 .

[22]  Giel Berden,et al.  Cavity ring-down spectroscopy : techniques and applications , 2009 .

[23]  Arthur M. Winer,et al.  RESPONSE OF COMMERCIAL CHEMILUMINESCENT NO-NO2 ANALYSERS TO OTHER NITROGEN-CONTAINING COMPOUNDS , 1974 .

[24]  S. Sander Temperature dependence of the NO3 absorption spectrum , 1986 .

[25]  Z. Bielecki,et al.  Cavity Enhanced Absorption Spectroscopy Sensor , 2009 .

[26]  F. Götz Ozone in the Atmosphere , 1951 .

[27]  A. Cho,et al.  Spectroscopic detection of biological NO with a quantum cascade laser , 2001, Applied physics. B, Lasers and optics.

[28]  J. Hodges,et al.  Low-uncertainty H2O line intensities for the 930-nm region , 2008 .

[29]  D. Spencer,et al.  Sensitive measurement of photon lifetime and true reflectances in an optical cavity by a phase-shift method. , 1980, Applied optics.

[30]  Martin Fechner,et al.  Cavity ring-down absorption spectrography based on filament-generated supercontinuum light. , 2009, Optics express.