Magnetic Calibration System With Interference Compensation

This paper describes a novel method for calibrating dc-precise magnetometers in the low field range ( $\pm 100~\mu \text{T}$ ), which gives acceptable results even in laboratory conditions with significant magnetic interference. By introducing a closely mounted reference magnetometer and a specific calibration procedure, it is possible to compensate for the external magnetic field disturbances caused, e.g., by the local transportation operated with dc power supplies. The field compensation occurs only shortly after the calibrating coils are energized. In this case, the leakage of the coil’s magnetic flux to the reference sensor due to the cancelation of the time-varying compensating field was negligible. When using 60 cm coils and reference sensor in 2.5 m distance, we were able to calculate magnetometer gains with a standard deviation of 91 ppm. We show that an overall uncertainty of 0.1% can be achieved.

[1]  Francisco Granziera,et al.  Three-Axial Helmholtz Coil Design and Validation for Aerospace Applications , 2018, IEEE Transactions on Aerospace and Electronic Systems.

[2]  W. Marsden I and J , 2012 .

[3]  Y. G. Kim,et al.  Precise standard system for low dc magnetic field reproduction , 2002 .

[4]  P. Alam,et al.  H , 1887, High Explosives, Propellants, Pyrotechnics.

[5]  Tsuyoshi Murata,et al.  {m , 1934, ACML.

[6]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[7]  Fritz Primdahl,et al.  Scalar calibration of vector magnetometers , 2000 .

[8]  Fritz Primdahl,et al.  Ørsted Pre-Flight Magnetometer Calibration Mission , 2003 .

[9]  Michal Ulvr,et al.  Precise Calibration Method for Triaxial Magnetometers Not Requiring Earth’s Field Compensation , 2015, IEEE Transactions on Instrumentation and Measurement.

[10]  P. Park,et al.  Low magnetic field measurement by a separated NMR detector using flowing water , 1997 .

[11]  L. Tanner,et al.  Magnetic Field Stabilization for Magnetically Shielded Volumes by External Field Coils , 2005, Journal of research of the National Institute of Standards and Technology.

[12]  M. J. Hall,et al.  Magnetic environment and magnetic field standards at NPL for the calibration of low noise magnetometers and gradiometers for cleanliness studies , 2012, 2012 ESA Workshop on Aerospace EMC.

[13]  W. F. Stuart Earth's field magnetometry , 1972 .

[14]  Michal Ulvr,et al.  Improvements to the NMR Method With Flowing Water at CMI , 2017, IEEE Transactions on Instrumentation and Measurement.

[15]  Fritz Primdahl,et al.  Transverse field effect in fluxgate sensors , 1997 .

[16]  J. Kirschvink,et al.  Uniform magnetic fields and double-wrapped coil systems: improved techniques for the design of bioelectromagnetic experiments. , 1992, Bioelectromagnetics.

[17]  Thomas de Quincey [C] , 2000, The Works of Thomas De Quincey, Vol. 1: Writings, 1799–1820.

[18]  K. Glassmeier,et al.  RPC-MAG The Fluxgate Magnetometer in the ROSETTA Plasma Consortium , 2007 .

[19]  C. Coillot,et al.  New Compensation Method for Cross-Axis Effect for Three-Axis AMR Sensors , 2013, IEEE Sensors Journal.

[20]  L. Puranen,et al.  Final report (draft B) on EUROMET Project No. 446: International comparison of magnetic flux density by means of field coil transfer standards , 2001 .