Real-time processing for Fourier domain optical coherence tomography using a field programmable gate array.

Real-time display of processed Fourier domain optical coherence tomography (FDOCT) images is important for applications that require instant feedback of image information, for example, systems developed for rapid screening or image-guided surgery. However, the computational requirements for high-speed FDOCT image processing usually exceeds the capabilities of most computers and therefore display rates rarely match acquisition rates for most devices. We have designed and developed an image processing system, including hardware based upon a field programmable gated array, firmware, and software that enables real-time display of processed images at rapid line rates. The system was designed to be extremely flexible and inserted in-line between any FDOCT detector and any Camera Link frame grabber. Two versions were developed for spectrometer-based and swept source-based FDOCT systems, the latter having an additional custom high-speed digitizer on the front end but using all the capabilities and features of the former. The system was tested in humans and monkeys using an adaptive optics retinal imager, in zebrafish using a dual-beam Doppler instrument, and in human tissue using a swept source microscope. A display frame rate of 27 fps for fully processed FDOCT images (1024 axial pixels x 512 lateral A-scans) was achieved in the spectrometer-based systems.

[1]  S. Yun,et al.  In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve. , 2004, Optics express.

[2]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[3]  J. Fujimoto,et al.  Buffered Fourier domain mode locking: Unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s. , 2006, Optics letters.

[4]  Daniel X Hammer,et al.  Foveal fine structure in retinopathy of prematurity: an adaptive optics Fourier domain optical coherence tomography study. , 2008, Investigative ophthalmology & visual science.

[5]  R. D. Ferguson,et al.  Three dimensional tracking for volumetric spectral-domain optical coherence tomography. , 2007, Optics express.

[6]  S. Yun,et al.  High-speed optical frequency-domain imaging. , 2003, Optics express.

[7]  Teresa C. Chen,et al.  Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography. , 2004, Optics express.

[8]  B. Bouma,et al.  Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. , 2003, Optics letters.

[9]  J. Duker,et al.  Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation. , 2004, Optics express.

[10]  R. D. Ferguson,et al.  Spectral-domain low coherence interferometry/optical coherence tomography system for fine needle breast biopsy guidance. , 2009, The Review of scientific instruments.

[11]  R. D. Ferguson,et al.  Compact multimodal adaptive-optics spectral-domain optical coherence tomography instrument for retinal imaging. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[12]  C. Compton,et al.  High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography. , 2000, Gastrointestinal endoscopy.

[13]  Daniel X Hammer,et al.  Dual-beam Fourier domain optical Doppler tomography of zebrafish. , 2008, Optics express.

[14]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[15]  J M Schmitt,et al.  Subsurface imaging of living skin with optical coherence microscopy. , 1995, Dermatology.

[16]  A J Welch,et al.  Spectrally resolved white-light interferometry for measurement of ocular dispersion. , 1999, Journal of the Optical Society of America. A, Optics, image science, and vision.

[17]  James G. Fujimoto,et al.  Optical Coherence Tomography of Ocular Diseases , 1995 .

[18]  Barry Cense,et al.  Autocalibration of spectral-domain optical coherence tomography spectrometers for in vivo quantitative retinal nerve fiber layer birefringence determination. , 2007, Journal of biomedical optics.

[19]  E. Halpern,et al.  Quantification of Macrophage Content in Atherosclerotic Plaques by Optical Coherence Tomography , 2003, Circulation.

[20]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[21]  A. Wear CIRCULATION , 1964, The Lancet.

[22]  A. Fercher,et al.  Measurement of intraocular distances by backscattering spectral interferometry , 1995 .

[23]  A. Fercher,et al.  In vivo human retinal imaging by Fourier domain optical coherence tomography. , 2002, Journal of biomedical optics.

[24]  J. Fujimoto,et al.  Optical coherence tomography using a frequency-tunable optical source. , 1997, Optics letters.

[25]  Michael Pircher,et al.  Retinal cone mosaic imaged with transverse scanning optical coherence tomography. , 2006, Optics letters.