Transient and Harmonic Voltages Associated with Automated Capacitor Switching on Distribution Systems

One of the functions proposed for distribution automation systems is automated capacitor switching to control power factor and voltage profile on feeder circuits. This is one of the functions being implemented as part of the Athens Automation and Control Experiment on the Athens Utilities Board (AUB) in Athens, Tennessee. A concern with automated capacitor switching is the increase in harmonic and transient voltages due to different capacitor configurations on the distribution system. A study was performed to evaluate the impact of the automated capacitor switching on the AUB distribution system. The study has identified problem areas, methods for determining the problem areas, and possible solutions. The substation capacitor banks were found to be the dominant factor in both the transient and harmonic repsonses of the distribution system. The harmonic response of the system is dominated by the parallel inductance/capacitance of the circuit comprised of the substation capacitor and equivalent source reactance at the substation. The transient analyses indicated that when the substation capacitor is energized, magnified transient voltages can occur at switched-in feeder capacitors. An evaluation of the effect of automated capacitor switching is necessary to properly design the automated capacitor switching schemes and the required arrester protection for any harmonic and/or transient overvoltage contingency.

[1]  M. McGranaghan,et al.  Digital Simulation of Distribution System Frequency-REsponse Characteristics , 1981, IEEE Transactions on Power Apparatus and Systems.

[2]  I. B. Johnson,et al.  Magnification of Switching Surges , 1958, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[3]  M. McGranaghan,et al.  Distribution Feeder Harmonic Study Methodology , 1984, IEEE Transactions on Power Apparatus and Systems.

[4]  S. L. Purucker,et al.  Feeder Automation Designs for Installing an Integrated Distribution Control System , 1985, IEEE Power Engineering Review.

[5]  M. F. McGranaghan,et al.  Overvoltage Protection of Shunt-Capacitor Banks Using MOV Arresters , 1984 .

[6]  M. McGranaghan,et al.  Overvoltage Protection of Shunt-Capacitor Banks Using MOV Arresters , 1984, IEEE Transactions on Power Apparatus and Systems.

[7]  S. Purucker,et al.  Feeder Automation Designs for Installing an Integrated Distribution Control System , 1985, IEEE Transactions on Power Apparatus and Systems.

[8]  I. B. Johnson,et al.  Magnification of switching surges , 1959, Electrical Engineering.

[9]  Roger C. Dugan,et al.  Harmonics and Reactive Power From Line-Commutated Inverters in Proposed Photovoltaic Subdivision , 1983, IEEE Power Engineering Review.