Physiological Driver Monitoring Using Capacitively Coupled and Radar Sensors

Unobtrusive monitoring of drivers’ physiological parameters is a topic gaining interest, potentially allowing to improve the performance of safety systems to prevent accidents, as well as to improve the driver’s experience or provide health-related services. In this article, two unobtrusive sensing techniques are evaluated: capacitively coupled sensing of the electrocardiogram and respiration, and radar-based sensing of heartbeat and respiration. A challenge for use of these techniques in vehicles are the vibrations and other disturbances that occur in vehicles to which they are inherently more sensitive than contact-based sensors. In this work, optimized sensor architectures and signal processing techniques are proposed that significantly improve the robustness to artefacts. Experimental results, conducted under real driving conditions on public roads, demonstrate the feasibility of the proposed approach. R peak sensitivities and positive predictivities higher than 98% both in highway and city traffic, heart rate mean absolute error of 1.02 bpm resp. 2.06 bpm in highway and city traffic and individual beat R-R interval 95% percentile error within ±27.3 ms are demonstrated. The radar experimental results show that respiration can be measured while driving and heartbeat can be recovered from vibration noise using an accelerometer-based motion reduction algorithm.

[1]  L. Murri,et al.  Transient autonomic nervous system dysfunction during hyperacute stroke , 2000, Acta neurologica Scandinavica.

[2]  Ghaïs El Zein,et al.  Microwave doppler radar for heartbeat detection vs electrocardiogram , 2012 .

[3]  Shyamal Patel,et al.  A review of wearable sensors and systems with application in rehabilitation , 2012, Journal of NeuroEngineering and Rehabilitation.

[4]  Changzhi Li,et al.  A Portable FMCW Interferometry Radar With Programmable Low-IF Architecture for Localization, ISAR Imaging, and Vital Sign Tracking , 2017, IEEE Transactions on Microwave Theory and Techniques.

[5]  A F Pacela,et al.  Impedance pneumography—A survey of instrumentation techniques , 1966, Medical & biological engineering.

[6]  Wim Van Paesschen,et al.  Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment , 2017, Sensors.

[7]  Alan V. Sahakian,et al.  Remote sensing of patterns of cardiac activity on an ambulatory subject using millimeter-wave interferometry and statistical methods , 2012, Medical & Biological Engineering & Computing.

[8]  S. Huffel,et al.  Influence of Mental Stress on Heart Rate and Heart Rate Variability , 2009 .

[9]  Paul Leroux,et al.  Analysis of an Indoor Biomedical Radar-Based System for Health Monitoring , 2013, IEEE Transactions on Microwave Theory and Techniques.

[10]  Tor Sverre Lande,et al.  Vital Sign Monitoring Through the Back Using an UWB Impulse Radar With Body Coupled Antennas , 2018, IEEE Transactions on Biomedical Circuits and Systems.

[11]  Jeroen J. Bax,et al.  Third universal definition of myocardial infarction , 2013, Nature Reviews Cardiology.

[12]  Tzyy-Sheng Horng,et al.  Chest-Worn Health Monitor Based on a Bistatic Self-Injection-Locked Radar , 2015, IEEE Transactions on Biomedical Engineering.

[13]  Edwin C. Kan,et al.  Monitoring vital signs over multiplexed radio by near-field coherent sensing , 2018 .

[14]  Changzhi Li,et al.  A Review on Recent Progress of Portable Short-Range Noncontact Microwave Radar Systems , 2017, IEEE Transactions on Microwave Theory and Techniques.

[15]  Seung Hun Kim,et al.  Reduction of Motion Artifacts and Improvement of R Peak Detecting Accuracy Using Adjacent Non-Intrusive ECG Sensors , 2016, Sensors.

[16]  Pablo Laguna,et al.  Drowsiness detection using heart rate variability , 2016, Medical & Biological Engineering & Computing.

[17]  Marco Mercuri,et al.  Sensor Fusion of Capacitively Coupled ECG and Continuous-Wave Doppler Radar for Improved Unobtrusive Heart Rate Measurements , 2018, IEEE Journal on Emerging and Selected Topics in Circuits and Systems.

[18]  Sabine Van Huffel,et al.  Evaluation of a Multichannel Non-Contact ECG System and Signal Quality Algorithms for Sleep Apnea Detection and Monitoring , 2018, Sensors.

[19]  Changzhi Li,et al.  Random Body Movement Cancellation in Doppler Radar Vital Sign Detection , 2008, IEEE Transactions on Microwave Theory and Techniques.

[20]  André Bourdoux,et al.  A Direct Phase-Tracking Doppler Radar Using Wavelet Independent Component Analysis for Non-Contact Respiratory and Heart Rate Monitoring , 2018, IEEE Transactions on Biomedical Circuits and Systems.

[21]  Dennis R. Morgan,et al.  Novel signal processing techniques for Doppler radar cardiopulmonary sensing , 2009, Signal Process..

[22]  Chris Van Hoof,et al.  Vital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensor , 2019, Nature Electronics.

[23]  André Bourdoux,et al.  Frequency-Tracking CW Doppler Radar Solving Small-Angle Approximation and Null Point Issues in Non-Contact Vital Signs Monitoring , 2017, IEEE Transactions on Biomedical Circuits and Systems.