Can combining economizers with improved filtration save energy and protect equipment in data centers? - eScholarship

Economizer use in data centers is an energy efficiency strategy that could significantly limit electricity demand in this rapidly growing economic sector. Widespread economizer implementation, however, has been hindered by potential equipment reliability concerns associated with exposing information technology equipment to particulate matter of outdoor origin. This study explores the feasibility of using economizers in data centers to save energy while controlling particle concentrations with high-quality air filtration. Physical and chemical properties of indoor and outdoor particles were analyzed at an operating northern California data center equipped with an economizer under varying levels of air filtration efficiency. Results show that when improved filtration is used in combination with an economizer, the indoor/outdoor concentration ratios for most measured particle types were similar to levels when using conventional filtration without economizers. An energy analysis of the data center reveals that, even during the summer months, chiller savings from economizer use greatly outweigh any increase in fan power associated with improved filtration. These findings indicate that economizer use combined with improved filtration could reduce data center energy demand while providing a level of protection from particles of outdoor origin similar to that observed with conventional design.

[1]  M. L. Laucks Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles , 2000 .

[2]  Bruce Nordman,et al.  Energy efficient data centers , 2004 .

[3]  Lance Wallace,et al.  Real-Time Measurements of Black Carbon Indoors and Outdoors: A Comparison of the Photoelectric Aerosol Sensor and the Aethalometer , 2005 .

[4]  Tracy L. Thatcher,et al.  The transformation of outdoor ammonium nitrate aerosols in the indoor environment , 2002 .

[5]  J. Seinfeld,et al.  Atmospheric Chemistry and Physics: From Air Pollution to Climate Change , 1997 .

[6]  Roy M. Harrison,et al.  Size-differentiated composition of inorganic atmospheric aerosols of both marine and polluted continental origin , 1983 .

[7]  Charles J. Weschler,et al.  Are Indoor Air Pollutants Threatening the Reliability , 1998 .

[8]  Barbara J. Turpin,et al.  Investigation of organic aerosol sampling artifacts in the los angeles basin , 1994 .

[9]  Alfred Wiedensohler,et al.  Variability of apparent particle density of an urban aerosol. , 2003, Environmental science & technology.

[10]  C I Davidson,et al.  The sizes of particulate sulfate and nitrate in the atmosphere--a review. , 1987, JAPCA.

[11]  S. T. Taylor,et al.  HVAC systems and equipment , 1990 .

[12]  Thomas W. Kirchstetter,et al.  Laboratory and field investigation of the adsorption of gaseous organic compounds onto quartz filters , 2001 .

[13]  W. Fisk,et al.  Performance and costs of particle air filtration technologies. , 2002, Indoor air.

[14]  M. Andreae,et al.  Black carbon or brown carbon? The nature of light-absorbing carbonaceous aerosols , 2006 .

[15]  Charles J. Weschler,et al.  Predictions of Benefits and Costs Derived from Improving Indoor Air Quality in Telephone Switching Offices , 1991 .

[16]  Judith C. Chow,et al.  Guideline on Speciated Particulate Monitoring , 1998 .

[17]  Thomas W. Kirchstetter,et al.  Controlled generation of black carbon particles from a diffusion flame and applications in evaluating black carbon measurement methods , 2007 .

[18]  Lidia Morawska,et al.  Variation in indoor particle number and PM2.5 concentrations in a radio station surrounded by busy roads before and after an upgrade of the HVAC system , 2009 .

[19]  H. C. Shields,et al.  Are indoor air pollutants threatening the reliability of your electronic equipment , 1998 .

[20]  Charles J. Weschler,et al.  Comparisons among VOCs Measured in Three Types of U.S. Commercial Buildings with Different Occupant Densities , 1996 .

[21]  Thomas E McKone,et al.  Indoor particulate matter of outdoor origin: importance of size-dependent removal mechanisms. , 2002, Environmental science & technology.

[22]  Roy M. Harrison,et al.  The equilibrium of ammonium chloride aerosol with gaseous hydrochloric acid and ammonia under tropospheric conditions , 1987 .

[23]  Timothy J Buckley,et al.  Real-Time Indoor and Outdoor Measurements of Black Carbon in an Occupied House: An Examination of Sources , 2002, Journal of the Air & Waste Management Association.

[24]  Judith C. Chow,et al.  Descriptive analysis of PM2.5 and PM10 at regionally representative locations during SJVAQS/AUSPEX , 1996 .

[25]  A J Gadgil,et al.  Hygroscopic fine mode particle deposition on electronic circuits and resulting degradation of circuit performance: an experimental study. , 2000, Indoor air.

[26]  Richard E. Brown,et al.  Report to Congress on Server and Data Center Energy Efficiency: Public Law 109-431 , 2008 .