Real-time tumor tracking using sequential kV imaging combined with respiratory monitoring: a general framework applicable to commonly used IGRT systems

Clinical image guided radiotherapy (IGRT) systems have kV imagers and respiratory monitors, the combination of which provides an 'internal-external' correlation for respiratory-induced tumor motion tracking. We developed a general framework of correlation-based position estimation that is applicable to various imaging configurations, particularly alternate stereoscopic (ExacTrac) or rotational monoscopic (linacs) imaging, where instant 3D target positions cannot be measured. By reformulating the least-squares estimation equation for the correlation model, the necessity to measure 3D target positions from synchronous stereoscopic images can be avoided. The performance of this sequential image-based estimation was evaluated in comparison with a synchronous image-based estimation. Both methods were tested in simulation studies using 160 abdominal/thoracic tumor trajectories and an external respiratory signal dataset. The sequential image-based estimation method (1) had mean 3D errors less than 1 mm at all the imaging intervals studied (0.2, 1, 2, 5 and 10 s), (2) showed minimal dependencies of the accuracy on the geometry and (3) was equal in accuracy to the synchronous image-based estimation method when using the same image input. In conclusion, the sequential image-based estimation method can achieve sub-mm accuracy for commonly used IGRT systems, and is equally accurate and more broadly applicable than the synchronous image-based estimation method.

[1]  Martin J Murphy,et al.  Tracking moving organs in real time. , 2004, Seminars in radiation oncology.

[2]  H. Kubo,et al.  Respiration gated radiotherapy treatment: a technical study. , 1996, Physics in medicine and biology.

[3]  K. Ohara,et al.  Irradiation synchronized with respiration gate. , 1989, International journal of radiation oncology, biology, physics.

[4]  Paul J Keall,et al.  Dynamic multileaf collimator tracking of respiratory target motion based on a single kilovoltage imager during arc radiotherapy. , 2010, International journal of radiation oncology, biology, physics.

[5]  Achim Schweikard,et al.  Respiration tracking in radiosurgery. , 2004, Medical physics.

[6]  Gregory C Sharp,et al.  Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors , 2004, Physics in medicine and biology.

[7]  Hiroki Shirato,et al.  Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: a simulation study. , 2007, Medical physics.

[8]  Yelin Suh,et al.  Use of MV and kV imager correlation for maintaining continuous real-time 3D internal marker tracking during beam interruptions. , 2009, Physics in medicine and biology.

[9]  P. Keall,et al.  A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoring. , 2008, Physics in medicine and biology.

[10]  M. Hoogeman,et al.  Clinical accuracy of the respiratory tumor tracking system of the cyberknife: assessment by analysis of log files. , 2009, International journal of radiation oncology, biology, physics.

[11]  Sergey Povzner,et al.  Management of three-dimensional intrafraction motion through real-time DMLC tracking. , 2008, Medical physics.

[12]  Warren D D'Souza,et al.  An analysis of the treatment couch and control system dynamics for respiration-induced motion compensation. , 2006, Medical physics.

[13]  R. Mohan,et al.  Motion adaptive x-ray therapy: a feasibility study , 2001, Physics in medicine and biology.

[14]  Paul J Keall,et al.  Real-time prostate trajectory estimation with a single imager in arc radiotherapy: a simulation study , 2009, Physics in medicine and biology.

[15]  Martin J Murphy,et al.  Issues in respiratory motion compensation during external-beam radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[16]  H. Shirato,et al.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.

[17]  H Shirato,et al.  Inference of hysteretic respiratory tumor motion from external surrogates: a state augmentation approach , 2008, Physics in medicine and biology.

[18]  Herbert Cattell,et al.  Toward submillimeter accuracy in the management of intrafraction motion: the integration of real-time internal position monitoring and multileaf collimator target tracking. , 2009, International journal of radiation oncology, biology, physics.

[19]  Paul J Keall,et al.  Three-dimensional prostate position estimation with a single x-ray imager utilizing the spatial probability density , 2008, Physics in medicine and biology.

[20]  Paul J Keall,et al.  An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients , 2008, Physics in medicine and biology.

[21]  Fang-Fang Yin,et al.  Use of the BrainLAB ExacTrac X-Ray 6D system in image-guided radiotherapy. , 2008, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.