Simultaneous quantification of methanol and ethanol in alcoholic beverage using a rapid gas chromatographic method coupling with dual internal standards

This study presented a direct GC method using dual internal standards to simultaneously determine ethanol and methanol in alcoholic beverages. The sample should only be spiked with proper amount of internal standards (100 μg 2-pentanol and 50 mg acetonitrile), and then directly injected into a mega-pore capillary column (CP-Wax 58 CB) with FID detector for GC analysis. The accurate content of ethanol and methanol in beverages could be obtained in less than 12 min. The reliability, accuracy and precision of the presented method were examined with the test of standard addition and recovery, comparison with standard methods, and the variation between intra-day and inter-day tests. All results from above tests suggested that the direct GC method presented in this study was as reliable as standard method proposed by AOAC but more rapid.

[1]  R. Fanelli,et al.  Trace analysis of methanol in rat serum by headspace high resolution gas chromatography/selected ion monitoring. , 1986, Journal of chromatographic science.

[2]  V. Gupta,et al.  Reagent system for the spectrophotometric determination of methanol in environmental and biological samples. , 1984, The Analyst.

[3]  S. J. Lin,et al.  Trace determination of methanol in water-ethanol solution by derivatization and high-performance liquid chromatography. , 1998, Journal of chromatography. A.

[4]  I. Karube,et al.  Selective flow-injection determination of methanol in the presence of ethanol based on a multi-enzyme system with chemiluminescence detection , 1993 .

[5]  T. Okada,et al.  Simultaneous determination of the concentration of methanol and relative humidity based on a single Nafion(Ag)-coated quartz crystal microbalance , 2000 .

[6]  F. Bindler,et al.  The problem of methanol concentration admissible in distilled fruit spirits. , 1988, Food additives and contaminants.

[7]  G. Reglero,et al.  Volatile composition of vinegars. Simultaneous distillation-extraction and gas chromatographic-mass spectrometric analysis , 1992 .

[8]  J. Kawagoe,et al.  Determination of methanol in whole blood by capillary gas chromatography with direct on-column injection. , 1991, Journal of chromatography.

[9]  F. Tagliaro,et al.  Direct injection high-performance liquid chromatographic method with electrochemical detection for the determination of ethanol and methanol in plasma using an alcohol oxidase reactor. , 1991, Journal of chromatography.

[10]  A. Smilde,et al.  Process analytical chemistry in the distillation industry using near-infrared spectroscopy , 1997 .

[11]  I. F. Dolmanova,et al.  Enzymic method for the determination of ethanol and methanol with spectrophotometric detection of the rate of the process , 1996 .

[12]  S. Cheung,et al.  Simultaneous determination of methanol, ethanol, acetone, isopropanol and ethylene glycol in plasma by gas chromatography. , 1987, Journal of chromatography.

[13]  Christine A. Miller,et al.  Development of a Rapid Method for the Analysis of Ethanol in Wines Using Capillary Electrophoresis , 1997, American Journal of Enology and Viticulture.

[14]  Chang Yong Lee,et al.  Determination of methyl alcohol in wine by gas chromatography , 1975 .

[15]  J. Andrade,et al.  Determination of methanol and ethanol by gas chromatrography following air sampling onto florisil cartridges and their concentrations at urban sites in the three largest cities in Brazil. , 1999 .