Continuous Pulse Oximetry and Capnography Monitoring for Postoperative Respiratory Depression and Adverse Events: A Systematic Review and Meta-analysis

BACKGROUND: Death and anoxic brain injury from unrecognized postoperative respiratory depression (PORD) is a serious concern for patient safety. The American Patient Safety Foundation has called for continuous electronic monitoring for all patients receiving opioids in the postoperative period. These recommendations are based largely on consensus opinion with currently limited evidence. The objective of this study is to review the current state of knowledge on the effectiveness of continuous pulse oximetry (CPOX) versus routine nursing care and the effectiveness of continuous capnography monitoring with or without pulse oximetry for detecting PORD and preventing postoperative adverse events in the surgical ward. METHODS: We performed a systematic search of the literature databases published between 1946 and May 2017. We selected the studies that included the following: (1) adult surgical patients (>18 years old); (2) prescribed opioids during the postoperative period; (3) monitored with CPOX and/or capnography; (4) primary outcome measures were oxygen desaturation, bradypnea, hypercarbia, rescue team activation, intensive care unit (ICU) admission, or mortality; and (5) studies published in the English language. Meta-analysis was performed using Cochrane Review Manager 5.3. RESULTS: In total, 9 studies (4 examining CPOX and 5 examining continuous capnography) were included in this systematic review. In the literature on CPOX, 1 randomized controlled trial showed no difference in ICU transfers (6.7% vs 8.5%; P = .33) or mortality (2.3% vs 2.2%). A prospective historical controlled trial demonstrated a significant reduction in ICU transfers (5.6–1.2 per 1000 patient days; P = .01) and rescue team activation (3.4–1.2 per 1000 patient days; P = .02) when CPOX was used. Overall, comparing the CPOX group versus the standard monitoring group, there was 34% risk reduction in ICU transfer (P = .06) and odds of recognizing desaturation (oxygen saturation [SpO2] <90% >1 hour) was 15 times higher (P < .00001). Pooled data from 3 capnography studies showed that continuous capnography group identified 8.6% more PORD events versus pulse oximetry monitoring group (CO2 group versus SpO2 group: 11.5% vs 2.8%; P < .00001). The odds of recognizing PORD was almost 6 times higher in the capnography versus the pulse oximetry group (odds ratio: 5.83, 95% confidence interval, 3.54–9.63; P < .00001). No studies examined the impact of continuous capnography on reducing rescue team activation, ICU transfers, or mortality. CONCLUSIONS: The use of CPOX on the surgical ward is associated with significant improvement in the detection of oxygen desaturation versus intermittent nursing spot-checks. There is a trend toward less ICU transfers with CPOX versus standard monitoring. The evidence on whether the detection of oxygen desaturation leads to less rescue team activation and mortality is inconclusive. Capnography provides an early warning of PORD before oxygen desaturation, especially when supplemental oxygen is administered. Improved education regarding monitoring and further research with high-quality randomized controlled trials is needed.

[1]  Jarrod E Dalton,et al.  Postoperative Hypoxemia Is Common and Persistent: A Prospective Blinded Observational Study , 2015, Anesthesia and analgesia.

[2]  Y. Daali,et al.  Codeine intoxication associated with ultrarapid CYP2D6 metabolism. , 2004, The New England journal of medicine.

[3]  C. Shapiro,et al.  Postoperative Sleep-Disordered Breathing in Patients Without Preoperative Sleep Apnea , 2015, Anesthesia and analgesia.

[4]  Lorri A. Lee,et al.  "No Patient Shall Be Harmed By Opioid-Induced Respiratory Depression" (Proceedings of "Essential Monitoring Strategies to Detect Clinically Significant Drug-Induced Respiratory Depression in the Postoperative Period" Conference) , 2011 .

[5]  C. K. Williams,et al.  Continuous Respiratory Monitoring and a “Smart” Infusion System Improve Safety of Patient-Controlled Analgesia in the Postoperative Period , 2008 .

[6]  David W Bates,et al.  Continuous monitoring in an inpatient medical-surgical unit: a controlled clinical trial. , 2014, The American journal of medicine.

[7]  R. Stoelting Continuous Postoperative Electronic Monitoring and the Will to Require It. , 2015, Anesthesia and analgesia.

[8]  J. Sprung,et al.  Multimodal Analgesic Protocol and Postanesthesia Respiratory Depression During Phase I Recovery After Total Joint Arthroplasty , 2015, Regional Anesthesia & Pain Medicine.

[9]  Melissa L. Langhan,et al.  The impact of capnography monitoring among children and adolescents in the postanesthesia care unit: a randomized controlled trial , 2017, Paediatric anaesthesia.

[10]  Robert A. Smith,et al.  Supplemental oxygen impairs detection of hypoventilation by pulse oximetry. , 2004, Chest.

[11]  D. Whitaker,et al.  Capnography standards for outside the operating room , 2016, Current opinion in anaesthesiology.

[12]  J. Miner,et al.  Does end tidal CO2 monitoring during emergency department procedural sedation and analgesia with propofol decrease the incidence of hypoxic events? A randomized, controlled trial. , 2010, Annals of emergency medicine.

[13]  C. Shapiro,et al.  Factors Associated with Postoperative Exacerbation of Sleep-disordered Breathing , 2014, Anesthesiology.

[14]  Medical device alarm safety in hospitals. , 2013, Sentinel event alert.

[15]  K. Scarfo,et al.  Capnography monitoring enhances safety of postoperative patient-controlled analgesia. , 2008, American health & drug benefits.

[16]  George W. Williams,et al.  A Comparison of Measurements of Change in Respiratory Status in Spontaneously Breathing Volunteers by the ExSpiron Noninvasive Respiratory Volume Monitor Versus the Capnostream Capnometer , 2017, Anesthesia and analgesia.

[17]  D. Bates,et al.  The Return on Investment of Implementing a Continuous Monitoring System in General Medical-Surgical Units* , 2014, Critical care medicine.

[18]  R. Etches Respiratory depression associated with patient-controlled analgesia: a review of eight cases , 1994, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[19]  R. Kothari,et al.  Incidence and Demographics of Post-Operative Naloxone Administration: A 13-Year Experience at a Major Tertiary Teaching Institution. , 2015, Pain physician.

[20]  R. Hutchison,et al.  Capnography and Respiratory Depression , 2008, The American journal of nursing.

[21]  T. Stijnen,et al.  Do sex differences exist in opioid analgesia? A systematic review and meta-analysis of human experimental and clinical studies , 2010, PAIN.

[22]  Bhavani Shankar Kodali,et al.  Capnography outside the operating rooms. , 2013, Anesthesiology.

[23]  T. Pellino,et al.  Incidence and characteristics of naloxone use in postoperative pain management: a critical examination of naloxone use as a potential quality measure. , 2005, Pain management nursing : official journal of the American Society of Pain Management Nurses.

[24]  Peter M. Suter,et al.  Transcutaneous Pco2 monitoring in critically ill adults: Clinical evaluation of a new sensor* , 2005, Critical care medicine.

[25]  Kelly A Saran,et al.  Life-threatening critical respiratory events: a retrospective study of postoperative patients found unresponsive during analgesic therapy. , 2011, Journal of clinical anesthesia.

[26]  A. Haynes,et al.  Predictors of In-hospital Postoperative Opioid Overdose After Major Elective Operations: A Nationally Representative Cohort Study , 2017, Annals of surgery.

[27]  J. Gräsner,et al.  How to avoid catastrophic events on the ward. , 2016, Best practice & research. Clinical anaesthesiology.

[28]  Postoperative Opioid-induced Respiratory Depression: A Closed Claims Analysis , 2015 .

[29]  S. Mcgrath,et al.  A Review of Current and Emerging Approaches to Address Failure-to-Rescue , 2011, Anesthesiology.

[30]  Joshua Pyke,et al.  A Comparison of Oxygen Saturation Data in Inpatients with Low Oxygen Saturation Using Automated Continuous Monitoring and Intermittent Manual Data Charting , 2014, Anesthesia and analgesia.

[31]  S. Mcgrath,et al.  Assessment of continuous acoustic respiratory rate monitoring as an addition to a pulse oximetry-based patient surveillance system , 2017, Journal of Clinical Monitoring and Computing.

[32]  A. Nicolini,et al.  Evaluation of a transcutaneous carbon dioxide monitor in patients with acute respiratory failure , 2011, Annals of thoracic medicine.

[33]  F. Chung,et al.  Chronic Opioid Use and Central Sleep Apnea: A Review of the Prevalence, Mechanisms, and Perioperative Considerations , 2015, Anesthesia and analgesia.

[34]  A. Binning,et al.  Observational study of perioperative PtcCO2 and SpO2 in non-ventilated patients receiving epidural infusion or patient-controlled analgesia using a single earlobe monitor (TOSCA). , 2007, British journal of anaesthesia.

[35]  P. Duke,et al.  Evaluation of respiratory volume monitoring (RVM) to detect respiratory compromise in advance of pulse oximetry and help minimize false desaturation alarms , 2016, The journal of trauma and acute care surgery.

[36]  R. Kozol,et al.  Postoperative day one: a high risk period for respiratory events. , 2005, American journal of surgery.

[37]  T. Voepel-Lewis,et al.  Pulse oximetry desaturation alarms on a general postoperative adult unit: a prospective observational study of nurse response time. , 2013, International Journal of Nursing Studies.

[38]  F. Chung,et al.  Does Obstructive Sleep Apnea Influence Perioperative Outcome? A Qualitative Systematic Review for the Society of Anesthesia and Sleep Medicine Task Force on Preoperative Preparation of Patients with Sleep-Disordered Breathing , 2016, Anesthesia and analgesia.

[39]  D. Meyer,et al.  Noninvasive Monitoring of Carbon Dioxide During Respiratory Failure in Toddlers and Infants: End-Tidal Versus Transcutaneous Carbon Dioxide , 1997, Anesthesia and analgesia.

[40]  J. Sprung,et al.  Timing of postoperative respiratory emergencies: when do they really occur? , 2016, Current opinion in anaesthesiology.

[41]  R. Bellomo,et al.  A prospective study of factors influencing the outcome of patients after a Medical Emergency Team review , 2008, Intensive Care Medicine.

[42]  S. R. Lewis,et al.  Pulse oximetry for perioperative monitoring. , 2014, The Cochrane database of systematic reviews.

[43]  M. Weiner,et al.  The Impact of Continuous Pulse Oximetry Monitoring on Intensive Care Unit Admissions from a Postsurgical Care Floor , 2006, Anesthesia and analgesia.

[44]  L. Oakes,et al.  American Society for Pain Management Nursing guidelines on monitoring for opioid-induced sedation and respiratory depression. , 2011, Pain management nursing : official journal of the American Society of Pain Management Nurses.

[45]  P. Gay,et al.  Society of Anesthesia and Sleep Medicine Guidelines on Preoperative Screening and Assessment of Adult Patients With Obstructive Sleep Apnea , 2016, Anesthesia and analgesia.

[46]  D. Rosenfeld,et al.  Findings of a Naloxone Database and its Utilization to Improve Safety and Education in a Tertiary Care Medical Center , 2016, Pain practice : the official journal of World Institute of Pain.

[47]  J. P. Curry,et al.  A critical assessment of monitoring practices, patient deterioration, and alarm fatigue on inpatient wards: a review , 2014, Patient Safety in Surgery.

[48]  T. Clutton-Brock,et al.  The benefits and pitfalls of pulse oximetry. , 1993, BMJ.

[49]  Frank J Overdyk,et al.  Continuous Oximetry/Capnometry Monitoring Reveals Frequent Desaturation and Bradypnea During Patient-Controlled Analgesia , 2007, Anesthesia and analgesia.

[50]  G. Blike,et al.  Impact of Pulse Oximetry Surveillance on Rescue Events and Intensive Care Unit Transfers: A Before-and-After Concurrence Study , 2010, Anesthesiology.

[51]  A. Dahan,et al.  Opioid-induced respiratory depression in the acute care setting: a compendium of case reports. , 2014, Pain management.

[52]  John B Downs,et al.  Has oxygen administration delayed appropriate respiratory care? Fallacies regarding oxygen therapy. , 2003, Respiratory care.

[53]  A. Dahan,et al.  Opioid-induced respiratory depression in paediatrics: a review of case reports. , 2013, British journal of anaesthesia.

[54]  D. Schroeder,et al.  Predictors of Delayed Postoperative Respiratory Depression Assessed from Naloxone Administration , 2015, Anesthesia and analgesia.

[55]  F. Overdyk,et al.  Smart respiratory monitoring: clinical development and validation of the IPI™ (Integrated Pulmonary Index) algorithm , 2016, Journal of Clinical Monitoring and Computing.

[56]  J. Janssens,et al.  Validity of transcutaneous PCO2 in monitoring chronic hypoventilation treated with non-invasive ventilation. , 2016, Respiratory medicine.

[57]  C. Shapiro,et al.  Postoperative Changes in Sleep-disordered Breathing and Sleep Architecture in Patients with Obstructive Sleep Apnea , 2014, Anesthesiology.

[58]  P. Eberhard The Design, Use, and Results of Transcutaneous Carbon Dioxide Analysis: Current and Future Directions , 2007, Anesthesia and analgesia.

[59]  K. Graham,et al.  Monitor alarm fatigue: standardizing use of physiological monitors and decreasing nuisance alarms. , 2010, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[60]  A. Dahan,et al.  High-inspired oxygen concentration further impairs opioid-induced respiratory depression. , 2013, British journal of anaesthesia.

[61]  H. Hosie,et al.  Limitations of pulse oximetry: respiratory insufficiency--a failure of detection. , 1993, BMJ.

[62]  M. Dean Opioids in renal failure and dialysis patients. , 2004, Journal of pain and symptom management.

[63]  C. Shapiro,et al.  Postoperative Oxygen Therapy in Patients With OSA: A Randomized Controlled Trial , 2017, Chest.

[64]  Y Takano,et al.  A comparison of the end-tidal CO2 measured by portable capnometer and the arterial PCO2 in spontaneously breathing patients. , 2003, Respiratory medicine.