Smart Characterization of Rogowski Coils by Using a Synthetized Signal

With the spread of new Low-Power Instrument Transformers (LPITs), it is fundamental to provide models and characterization procedures to estimate and even predict the LPITs’ behavior. In fact, distribution system operators and designers of network models are looking for all forms of information which may help the management and the control of power networks. For this purpose, the paper wants to contribute to the scientific community presenting a smart characterization procedure which easily provides sufficient information to predict the output signal of a Low-Power Current Transformer (LPCT), the Rogowski coil. The presented procedure is based on a synthetized signal applied to the Rogowski coil. Afterwards, the validity of the procedure is assessed within the Matlab environment and then by applying it on three off-the-shelf Rogowski coils. Simulations and experimental tests and results involving a variety of distorted signals in the power quality frequency range and by adopting a quite simple measurement setup demonstrated the effectiveness and the capability of the procedure to correctly estimate the output of the tested device.

[1]  H. Hegedus,et al.  Exploring New Frontiers of Instrumentation and Methods for Electrical and Electronic Measurements , 2008 .

[2]  Alberto Geri,et al.  Thermal Effects of Ground Faults on MV Joints and Cables , 2019, Energies.

[3]  Mohammad Hamed Samimi,et al.  The Rogowski Coil Principles and Applications: A Review , 2015, IEEE Sensors Journal.

[4]  Yong Zhen Gong,et al.  Analysis and Research of Rogowski Coil Current Sensing Technology , 2014 .

[6]  Qin Zhang,et al.  Design and Construction of a Rogowski Coil for Measuring Wide Pulsed Current , 2011, IEEE Sensors Journal.

[7]  Jari K. Hällström,et al.  Onsite Calibration of a Current Transformer Using a Rogowski Coil , 2009, IEEE Transactions on Instrumentation and Measurement.

[8]  A. Tokuchi,et al.  Design and Analysis on Coil Parameter of Linear Rogowski Coil for Measurement of High Frequency Pulsed Current , 2019, 2019 IEEE Pulsed Power & Plasma Science (PPPS).

[9]  Daniele Gallo,et al.  Impact of inductive current transformers on synchrophasor measurement in presence of modulations , 2020 .

[10]  C. Uçak,et al.  Improved Magnetic Circuit Model for Magnetic Shielding Effectiveness in Rogowski Coil , 2020, IEEE Transactions on Magnetics.

[11]  Tianshu Bi,et al.  Electronic transformer performance evaluation and its impact on PMU , 2019 .

[12]  M. Argüeso,et al.  Implementation of a Rogowski coil for the measurement of partial discharges , 2005 .

[13]  Yang Fan,et al.  Characteristic study of electronic voltage transformers' accuracy on harmonics , 2016, 2016 China International Conference on Electricity Distribution (CICED).

[14]  Mirko Marracci,et al.  Study and characterization of a Rogowski coil with superparamagnetic magnetite core , 2017, 2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[15]  Jaime S. Cardoso,et al.  Insulator visual non-conformity detection in overhead power distribution lines using deep learning , 2019, Comput. Electr. Eng..

[16]  Lorenzo Peretto,et al.  Accuracy Evaluation of an Equivalent Synchronization Method for Assessing the Time Reference in Power Networks , 2018, IEEE Transactions on Instrumentation and Measurement.

[17]  Lorenzo Peretto,et al.  Test Setup Design, and Calibration for Tan Delta Measurements on MV Cable Joints , 2018, 2018 IEEE 9th International Workshop on Applied Measurements for Power Systems (AMPS).

[18]  Lorenzo Peretto,et al.  A novel equivalent power network impedance approach for assessing the time reference in asynchronous measurements , 2017, 2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[19]  Doug Goodwin,et al.  Incorporating instrument transformer errors to voltage stability assessment , 2010, 2010 20th Australasian Universities Power Engineering Conference.

[20]  Lorenzo Peretto,et al.  Low-Cost Monitoring Unit for MV Cable Joints Diagnostics , 2018, 2018 IEEE 9th International Workshop on Applied Measurements for Power Systems (AMPS).

[21]  Hans Edin,et al.  High-Frequency Model of the Rogowski Coil With a Small Number of Turns , 2007, IEEE Transactions on Instrumentation and Measurement.

[22]  C. Arderne,et al.  Predictive mapping of the global power system using open data , 2020, Scientific Data.

[23]  Lorenzo Peretto,et al.  A Simple Modelling Procedure of Rogowski Coil for Power Systems Applications , 2019, 2019 IEEE 10th International Workshop on Applied Measurements for Power Systems (AMPS).

[24]  Haiming Shao,et al.  The Research on Additional Errors of Voltage Transformer Connected in Series , 2020, IEEE Access.

[25]  Enrique Personal,et al.  Key performance indicators: A useful tool to assess Smart Grid goals , 2014 .

[26]  Lorenzo Peretto,et al.  Low power voltage transformer accuracy class effects on the residual voltage measurement , 2018, 2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[27]  Muzamir Isa,et al.  The Rogowski Coil Sensor in High Current Application: A Review , 2018 .

[28]  Wang Gang,et al.  Research on measurement accuracy of EVT during the surge , 2014, 2014 International Conference on Power System Technology.

[29]  Zhibin Zhao,et al.  Research on Small Square PCB Rogowski Coil Measuring Transient Current in the Power Electronics Devices , 2019, Sensors.

[30]  Massimo Pompili,et al.  Faults Evaluation of MV Underground Cable Joints , 2019, 2019 AEIT International Annual Conference (AEIT).

[31]  M. Lukowicz,et al.  Optimized bandpass admittance criteria for earth fault protection of MV distribution networks , 2020 .

[32]  Mario Chiampi,et al.  Evaluation of Flexible Rogowski Coil Performances in Power Frequency Applications , 2011, IEEE Transactions on Instrumentation and Measurement.

[33]  Newton da Silva,et al.  Adaptive current harmonic estimation under fault conditions for smart grid systems , 2020 .

[34]  A. Beroual,et al.  Surface Discharges and Flashover Modelling of Solid Insulators in Gases , 2020 .

[35]  Hongbin Li,et al.  Comparative analysis of various models of Rogowski coil for very fast transient study , 2018 .

[36]  Michal Kaczmarek,et al.  Measurement error of non-sinusoidal electrical power and energy caused by instrument transformers , 2016 .

[37]  Kimmo Kauhaniemi,et al.  Online condition monitoring of MV cable feeders using Rogowski coil sensors for PD measurements , 2019, Electric Power Systems Research.

[38]  Edson Guedes da Costa,et al.  Inspection in overhead insulators through the analysis of the irradiated RF spectrum , 2019 .

[39]  Luis Romeral,et al.  Motor Fault Detection Using a Rogowski Sensor Without an Integrator , 2009, IEEE Transactions on Industrial Electronics.

[40]  P. Ripka Electric current sensors: a review , 2010 .

[41]  Lorenzo Peretto,et al.  Uncertainty sources analysis of a calibration system for the accuracy vs. temperature verification of voltage transformers , 2018, Journal of Physics: Conference Series.

[42]  Zhao Xi-cai,et al.  PERFORMANCE ANALYSIS OFAIR-CORE CURRENT TRANSFORMER , 2004 .

[43]  M. Lehtonen,et al.  Calibration of on-line partial discharge measuring system using Rogowski coil in covered-conductor overhead distribution networks , 2011 .

[44]  Zhenxing Li,et al.  An improved digital integral algorithm to enhance the measurement accuracy of Rogowski coil-based electronic transformers , 2020 .