Conventional angiography is the current standard for the evaluation of carotid artery disease. The excellent resolution of this invasive study is offset by the potential for contrast-related, embolic, and puncture site complications. Three-dimensional magnetic resonance angiography may offer a noninvasive diagnostic alternative. We examined this possibility by performing both conventional angiography and three-dimensional magnetic resonance angiography in 13 patients. Cervical duplex scans were also obtained in these patients. Contiguous transverse cervical magnetic resonance images were acquired in a 1.5 tesla magnet, by use of a posterior neck coil and a gradient echo pulse sequence. These "raw" data were transferred to a real-time workstation where three-dimensional cervical arterial images were reformatted, magnified, and examined from multiple angles. Total study time from patient positioning to image generation was approximately 30 minutes. In all patients, on three-dimensional magnetic resonance angiography the common, external, and internal carotid arteries and distal vertebral arteries were easily discernable and correctly identified as patent, stenotic, or occluded. Three-dimensional magnetic resonance angiography was not accurate in detecting carotid ulcers. The degree of internal carotid artery stenosis measured from the three-dimensional magnetic resonance angiography studies correlated well with the internal carotid artery stenosis measured with conventional angiography (r = 0.866, r2 = 75.1%, p = less than or equal to 0.0001). This recent technologic advance represents significant progress toward achieving the goal of completely noninvasive vascular assessment in this patient population.
[1]
W. Moore,et al.
Effect of flow rate and vessel calibre on critical arterial stenosis.
,
1979,
The Journal of surgical research.
[2]
D. Sumner,et al.
Computerized Ultrasonic Arteriography: A New Technique for Imaging the Carotid Bifurcation
,
1982,
IEEE Transactions on Biomedical Engineering.
[3]
F. Moll,et al.
Digital video subtraction angiography and duplex scanning in assessment of carotid artery disease: comparison with conventional angiography.
,
1983,
Surgery.
[4]
J. Weinreb,et al.
Diagnosis of carotid artery stenosis: comparison of 2DFT time-of-flight MR angiography with contrast angiography in 50 patients.
,
1991,
AJNR. American journal of neuroradiology.
[5]
David Baraff,et al.
Physician's Workstation with Real-Time Performance
,
1985,
IEEE Computer Graphics and Applications.
[6]
P. J. Keller,et al.
MR angiography with two-dimensional acquisition and three-dimensional display. Work in progress.
,
1989,
Radiology.