Design of an 99%-efficient, 5kW, phase-shift PWM DC-DC converter for telecom applications

In the last decade power electronic research focused on the power density maximization mainly to reduce initial systems costs [1]. In the field of data centers and telecom applications, the costs for powering and cooling exceed the purchasing cost in less than 2 years [2]. That causes the changing driving forces in the development of new power supplies to efficiency, while the power density should stay on a high level. The commonly used DC-DC converter in the power supply unit (PSU) for data centers and telecom applications are full bridge phase-shift converters since they meet the demands of high power and efficient power conversion, a compact design and the constant operation frequency allows a simple control and EMI design. The development of the converter with respect to high efficiency has a lot of degrees of freedom. An optimization procedure based on comprehensive analytical models leads to the optimal parameters (e.g. switching frequency, switching devices in parallel and transformer design) for the most efficient design. In this paper a 5kW, 400V–48⋖56V phase-shift PWM converter with LC-output filter is designed for highest efficiency (η ≥99%) with a volume limitation and the consideration of the part-load efficiency. The components dependency as well as the optimal design will be explained. The realized prototype design reaches a calculated efficiency of η = 99.2% under full load condition and a power density of ρ = 36W/in3 (2.2 kW/liter).

[1]  U. Drofenik,et al.  PWM Converter Power Density Barriers , 2007, 2007 Power Conversion Conference - Nagoya.

[2]  J.W. Kolar,et al.  An Optimized 5 kW, 147 W/in3 Telecom Phase-Shift DC-DC Converter with Magnetically Integrated Current Doubler , 2009, 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition.

[3]  Jan Abraham Ferreira,et al.  Improved analytical modeling of conductive losses in magnetic components , 1994 .

[4]  Charles R. Sullivan,et al.  Accurate prediction of ferrite core loss with nonsinusoidal waveforms using only Steinmetz parameters , 2002, 2002 IEEE Workshop on Computers in Power Electronics, 2002. Proceedings..

[5]  J. Biela,et al.  Exploring the pareto front of multi-objective single-phase PFC rectifier design optimization - 99.2% efficiency vs. 7kW/din3 power density , 2009, 2009 IEEE 6th International Power Electronics and Motion Control Conference.

[6]  J.W. Kolar,et al.  Impact of power density maximization on efficiency of dc-dc converter systems , 2007, 2007 7th Internatonal Conference on Power Electronics.

[7]  J.W. Kolar,et al.  Impact of Power Density Maximization on Efficiency of DC–DC Converter Systems , 2009, IEEE Transactions on Power Electronics.