Calibration procedure for a laser triangulation scanner with uncertainty evaluation

Abstract Most of low cost 3D scanning devices that are nowadays available on the market are sold without a user calibration procedure to correct measurement errors related to changes in environmental conditions. In addition, there is no specific international standard defining a procedure to check the performance of a 3D scanner along time. This paper aims at detailing a thorough methodology to calibrate a 3D scanner and assess its measurement uncertainty. The proposed procedure is based on the use of a reference ball plate and applied to a triangulation laser scanner. Experimental results show that the metrological performance of the instrument can be greatly improved by the application of the calibration procedure that corrects systematic errors and reduces the device's measurement uncertainty.

[1]  Paolo Minetola,et al.  Contactless inspection of castings: analysis of alignment procedures , 2012 .

[2]  Gabriele Guidi,et al.  Performance Evaluation of Triangulation Based Range Sensors , 2010, Sensors.

[3]  Chung How Kau,et al.  Measuring adult facial morphology in three dimensions. , 2009, The Angle orthodontist.

[4]  Gianfranco Genta,et al.  Measurements for Decision Making , 2013 .

[5]  Jeremy Knox,et al.  A Comparison of Plaster, Digital and Reconstructed Study Model Accuracy , 2008, Journal of orthodontics.

[6]  Jigui Zhu,et al.  Calibration technology in application of robot-laser scanning system , 2012 .

[7]  Patrick J. Flynn,et al.  An evaluation of multimodal 2D+3D face biometrics , 2005, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[8]  Mona Hess,et al.  Towards fully automatic reliable 3D acquisition: From designing imaging network to a complete and accurate point cloud , 2014, Robotics Auton. Syst..

[9]  Hsi-Yung Feng,et al.  Analysis of digitizing errors of a laser scanning system , 2001 .

[10]  Wang Wei,et al.  Calibration of laser scanning system based on a 2D ball plate , 2009 .

[11]  J. W. Humberston Classical mechanics , 1980, Nature.

[12]  Jean-François Fontaine,et al.  Systematic error correction of a 3D laser scanning measurement device , 2011 .

[13]  N. Draper,et al.  Applied Regression Analysis , 1967 .

[14]  Qing-Hua Huang,et al.  An optical coherence tomography (OCT)-based air jet indentation system for measuring the mechanical properties of soft tissues , 2009, Measurement science & technology.

[15]  Jorge Santolaria,et al.  A one-step intrinsic and extrinsic calibration method for laser line scanner operation in coordinate measuring machines , 2009 .

[16]  H. Kunzmann,et al.  Results of the international comparison of ball plate measurements in CIRP and WECC , 1995 .

[17]  Jean-Pierre Kruth,et al.  A performance evaluation test for laser line scanners on CMMs , 2007 .

[18]  Gianfranco Genta,et al.  Features and performance of some outlier detection methods , 2011 .

[19]  William Chauvenet,et al.  A manual of spherical and practical astronomy , 1891 .