Viability and performance of demountable composite connectors

Abstract Material production, and associated carbon emissions, could be reduced by reusing products instead of landfilling or recycling them. Steel beams are well suited to reuse, but are difficult to reuse when connected compositely to concrete slabs using welded studs. A demountable connection would allow composite performance but also permit reuse of both components at end-of-life. Three composite beams, of 2 m, 10 m and 5 m length, are constructed using M20 bolts as demountable shear connectors. The beams are tested in three-, six- and four-point bending, respectively. The former two are loaded to service, unloaded, demounted and reassembled; all three are tested to failure. The results show that all three have higher strengths than predicted using Eurocode 4. The longer specimens have performance similar to previously published comparable welded-connector composite beam results. This suggests that demountable composite beams can be safely used and practically reused, thus reducing carbon emissions.

[1]  L. Dallam,et al.  High Strength Bolt Shear Connectors -Pushout Tests , 1968 .

[2]  Buick Davison,et al.  Design for deconstruction and material reuse , 2011 .

[3]  R P Johnson,et al.  MODELS AND DESIGN RULES FOR STUD SHEAR CONNECTORS IN TROUGHS OF PROFILED SHEETING. , 1998 .

[4]  Jawed Qureshi,et al.  Behaviour of Headed Shear Stud in Composite Beams with Profiled Metal Decking , 2012 .

[5]  H. D. Wright,et al.  Shear connection between composite slabs and steel beams , 1990 .

[6]  Mark D. Webster,et al.  Designing Structural Systems for Deconstruction: How to Extend a New Building's Useful Life and Prevent it from Going to Waste When the End Finally Comes , 2005 .

[7]  R P Johnson,et al.  EXISTING RULES AND NEW TESTS FOR STUD SHEAR CONNECTORS IN TROUGHS OF PROFILED SHEETING. , 1998 .

[8]  Mark A Bradford,et al.  Sustainable Composite Beam Behaviour with Deconstructable Bolted Shear Connectors , 2016 .

[9]  Dennis Lam,et al.  Shear Capacity of Demountable Shear Connectors , 2012 .

[10]  Ehab Ellobody,et al.  Performance of shear connection in composite beams with profiled steel sheeting , 2006 .

[11]  R P Johnson,et al.  PARTIAL SHEAR CONNECTION IN COMPOSITE BEAMS FOR BUILDINGS. , 1991 .

[12]  Neil M. Hawkins,et al.  Seismic Response of Composite Shear Connections , 1984 .

[13]  Bill Addis,et al.  Building with Reclaimed Components and Materials: A Design Handbook for Reuse and Recycling , 2006 .

[14]  G. H. Couchman,et al.  Strength and ductility of headed stud shear connectors in profiled steel sheeting , 2010 .

[15]  R. P. Johnson,et al.  Design of composite steel and concrete structures , 1993 .

[16]  Dennis Lam Steel Concrete Composite and Hybrid Structures , 2009 .

[17]  Siegfried Bauer,et al.  Sustainable materials: With both eyes open , 2012 .

[18]  Daniel B Müller,et al.  Forging the anthropogenic iron cycle. , 2007, Environmental science & technology.

[19]  Michael D. Engelhardt,et al.  Behavior of post-installed shear connectors under static and fatigue loading , 2010 .

[20]  Stephen Hicks,et al.  Strength and Ductility of Headed Stud Connectors Welded in Modern Profiled Steel Sheeting , 2009 .

[21]  Mark A. Bradford,et al.  Composite Steel and Concrete Structural Members: Fundamental Behaviour , 1995 .