Performance of in-pixel circuits for photon counting arrays (PCAs) based on polycrystalline silicon TFTs.

Photon counting arrays (PCAs), defined as pixelated imagers which measure the absorbed energy of x-ray photons individually and record this information digitally, are of increasing clinical interest. A number of PCA prototypes with a 1 mm pixel-to-pixel pitch have recently been fabricated with polycrystalline silicon (poly-Si)-a thin-film technology capable of creating monolithic imagers of a size commensurate with human anatomy. In this study, analog and digital simulation frameworks were developed to provide insight into the influence of individual poly-Si transistors on pixel circuit performance-information that is not readily available through empirical means. The simulation frameworks were used to characterize the circuit designs employed in the prototypes. The analog framework, which determines the noise produced by individual transistors, was used to estimate energy resolution, as well as to identify which transistors contribute the most noise. The digital framework, which analyzes how well circuits function in the presence of significant variations in transistor properties, was used to estimate how fast a circuit can produce an output (referred to as output count rate). In addition, an algorithm was developed and used to estimate the minimum pixel pitch that could be achieved for the pixel circuits of the current prototypes. The simulation frameworks predict that the analog component of the PCA prototypes could have energy resolution as low as 8.9% full width at half maximum (FWHM) at 70 keV; and the digital components should work well even in the presence of significant thin-film transistor (TFT) variations, with the fastest component having output count rates as high as 3 MHz. Finally, based on conceivable improvements in the underlying fabrication process, the algorithm predicts that the 1 mm pitch of the current PCA prototypes could be reduced significantly, potentially to between ~240 and 290 μm.

[1]  Satoshi Yamada,et al.  Experimental evaluation of a-Se and CdTe flat-panel x-ray detectors for digital radiography and fluoroscopy , 2000, Medical Imaging.

[2]  G Raso,et al.  High-rate x-ray spectroscopy in mammography with a CdTe detector: a digital pulse processing approach. , 2010, Medical physics.

[3]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[4]  R. Dinapoli,et al.  Medipix2: A 64-k pixel readout chip with 55-/spl mu/m square elements working in single photon counting mode , 2001 .

[5]  Katsuyuki Taguchi,et al.  Characterization of a novel photon counting detector for clinical CT: count rate, energy resolution, and noise performance , 2009, Medical Imaging.

[6]  Olivier Limousin,et al.  New trends in CdTe and CdZnTe detectors for X- and gamma-ray applications , 2003 .

[7]  Robert A. Street,et al.  Laser processing of amorphous silicon for large-area polysilicon imagers , 2001 .

[8]  G. Meddeler,et al.  A Readout Chip for a 64 x 64 Pixel Matrix with 15-bit Single Photon Counting* , 1997 .

[9]  Yannis Tsividis,et al.  Operation and Modeling of the Mos Transistor (The Oxford Series in Electrical and Computer Engineering) , 2004 .

[10]  Qihua Zhao,et al.  Active pixel imagers incorporating pixel-level amplifiers based on polycrystalline-silicon thin-film transistors. , 2009, Medical physics.

[11]  Y. Tsividis Operation and modeling of the MOS transistor , 1987 .

[12]  E. E. Haller,et al.  Effects of X-ray and γ-ray Irradiation on GaN , 1996 .

[13]  P. Shikhaliev,et al.  Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application , 2011, Physics in medicine and biology.

[14]  T. Takahashi,et al.  Single photon counting X-ray imaging with Si and CdTe single chip pixel detectors and multichip pixel modules , 2004, IEEE Transactions on Nuclear Science.

[15]  Katsuyuki Taguchi,et al.  Modeling the performance of a photon counting x-ray detector for CT: energy response and pulse pileup effects. , 2011, Medical physics.

[16]  Franziska Hoffmann,et al.  Design Of Analog Cmos Integrated Circuits , 2016 .

[17]  Mats Danielsson,et al.  Measurements on a full-field digital mammography system with a photon counting crystalline silicon detector , 2003, SPIE Medical Imaging.

[18]  Matteo Perenzoni,et al.  A Multispectral Analog Photon-Counting Readout Circuit for X-ray Hybrid Pixel Detectors , 2008, IEEE Transactions on Instrumentation and Measurement.

[19]  K. Taguchi,et al.  Vision 20/20: Single photon counting x-ray detectors in medical imaging. , 2013, Medical physics.

[20]  N. Wermes,et al.  A photon counting pixel chip with energy windowing , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[21]  Tor A. Fjeldly,et al.  Unified model for short-channel poly-Si TFTs , 1999 .

[22]  Michael Campbell,et al.  Medipix3: A 64 k pixel detector readout chip working in single photon counting mode with improved spectrometric performance , 2011 .

[23]  Erik Fredenberg,et al.  Energy resolution of a photon-counting silicon strip detector , 2010, 2101.07789.

[24]  Erik Fredenberg,et al.  A photon-counting detector for dual-energy breast tomosynthesis , 2009, Medical Imaging.

[25]  Hao Jiang,et al.  Initial steps toward the realization of large area arrays of single photon counting pixels based on polycrystalline silicon TFTs , 2014, Medical Imaging.

[26]  Larry E. Antonuk,et al.  Effects of x-ray irradiation on polycrystalline silicon, thin-film transistors , 2006 .