A comparison of the optimal multiplier in polar and rectangular coordinates

Studies of the optimal multiplier (or optimal step size) modification to the standard Newton-Raphson (NR) load flow have mainly focused on highly stressed and unsolvable systems. This paper extends these previous studies by comparing performance of the NR load flow with and without optimal multipliers for a variety of unstressed, stressed, and unsolvable systems. Also, the impact of coordinate system choice in representing the voltage phasor at each bus is considered. In total, four solution methods are compared: the NR algorithm with and without optimal multipliers using polar and rectangular coordinates. This comparison is carried out by combining analysis of the optimal multiplier technique with empirical results for two-bus, 118-bus, and 10 274-bus test cases. These results indicate that the polar NR load flow with optimal multipliers is the best method of solution for both solvable and unsolvable cases.

[1]  Daniel Tylavsky,et al.  A nondiverging polar-form Newton-based power flow , 1988 .

[2]  S. Granville,et al.  Application of interior point methods to power flow unsolvability , 1996 .

[3]  James S. Thorp,et al.  Load-flow fractals draw clues to erratic behaviour , 1997 .

[4]  O. Alsac,et al.  Fast Decoupled Load Flow , 1974 .

[5]  B. Stott Effective starting process for Newton-Raphson load flows , 1971 .

[6]  S. C. Srivastava,et al.  Fast decoupled load flow methods in rectangular coordinates , 1991 .

[7]  C. Castro,et al.  A critical evaluation of step size optimization based load flow methods , 2000 .

[8]  Thomas J. Overbye,et al.  Techniques for improving power flow convergence , 2000, 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134).

[9]  Cleve Moler,et al.  Mathematical Handbook for Scientists and Engineers , 1961 .

[10]  P. R. Bijwe,et al.  Nondivergent fast power flow methods , 2003 .

[11]  Hsiao-Dong Chiang,et al.  CPFLOW: a practical tool for tracing power system steady-state stationary behavior due to load and generation variations , 1995 .

[12]  B. Stott,et al.  Review of load-flow calculation methods , 1974 .

[13]  William F. Tinney,et al.  Power Flow Solution by Newton's Method , 1967 .

[14]  Philip G. Hill,et al.  Power generation , 1927, Journal of the A.I.E.E..

[15]  Y. Tamura,et al.  A Load Flow Calculation Method for Ill-Conditioned Power Systems , 1981, IEEE Transactions on Power Apparatus and Systems.

[16]  Victor H. Quintana,et al.  Studies of load flow methods in polar and rectangular coordinates , 1991 .

[17]  T. Overbye A power flow measure for unsolvable cases , 1994 .

[18]  S. Iwamoto,et al.  A Load Flow Calculation Method for III-Conditioned Power Systems , 1981 .